Literature DB >> 24424127

Visual endpoint detection of Escherichia coli O157:H7 using isothermal Genome Exponential Amplification Reaction (GEAR) assay and malachite green.

Prithiviraj Jothikumar1, Jothikumar Narayanan2, Vincent R Hill3.   

Abstract

Rapid and specific detection methods for bacterial agents in drinking water are important for disease prevention and responding to suspected contamination events. In this study, an isothermal Genome Exponential Amplification Reaction (GEAR) assay for Escherichia coli O157:H7 was designed specifically to recognize a 199-bp fragment of the lipopolysaccharide gene (rfbE) for rapid testing of water samples. The GEAR assay was found to be specific for E. coli O157:H7 using 10 isolates of E. coli O157:H7 and a panel of 86 bacterial controls. The GEAR assay was performed at a constant temperature of 65°C using SYTO 9 intercalating dye. Detection limits were determined to be 20 CFU for the GEAR assay. When SYTO 9 fluorescence was measured using a real-time PCR instrument, the assay had the same detection limit as when malachite green was added to the reaction mix and a characteristic blue color was visually observed in positive reactions. The study also found that 50 and 20 CFU of E. coli O157:H7 seeded into 100-liter of tap water could be detected by the GEAR assays after the sample was concentrated by hollow-fiber ultrafiltration (HFUF) and approximately 10% of HFUF concentrate was cultured using trypticase soy broth-novobiocin. When applied to 19 surface water samples collected from Tennessee and Kentucky, the GEAR assay and a published real-time PCR assay both detected E. coli O157:H7 in two of the samples. The results of this study indicate that the GEAR assay can be sensitive for rapid detection of E. coli O157:H7 in water samples using fluorometric instruments and visual endpoint determination. Published by Elsevier B.V.

Entities:  

Keywords:  E. coli O157:H7; Isothermal amplification; Malachite green; Molecular assay; Water microbiology

Mesh:

Substances:

Year:  2014        PMID: 24424127     DOI: 10.1016/j.mimet.2014.01.002

Source DB:  PubMed          Journal:  J Microbiol Methods        ISSN: 0167-7012            Impact factor:   2.363


  7 in total

1.  Implications of direct amplification for measuring antimicrobial resistance using point-of-care devices.

Authors:  M R Williams; R D Stedtfeld; H Waseem; T Stedtfeld; B Upham; W Khalife; B Etchebarne; M Hughes; J M Tiedje; S A Hashsham
Journal:  Anal Methods       Date:  2017-01-31       Impact factor: 2.896

2.  Development of a Potential Penside Colorimetric LAMP Assay Using Neutral Red for Detection of African Swine Fever Virus.

Authors:  Yang Wang; Junfei Dai; Yongsheng Liu; Jifei Yang; Qian Hou; Yunwen Ou; Yaozhong Ding; Bing Ma; Haotai Chen; MiaoMiao Li; Yuefeng Sun; Haixue Zheng; Keshan Zhang; Ashenafi Kiros Wubshet; Alexei D Zaberezhny; Taras I Aliper; Kazimierz Tarasiuk; Zygmunt Pejsak; Zhijie Liu; Yongguang Zhang; Jie Zhang
Journal:  Front Microbiol       Date:  2021-04-23       Impact factor: 5.640

3.  Use of Malachite Green-Loop Mediated Isothermal Amplification for Detection of Plasmodium spp. Parasites.

Authors:  Naomi W Lucchi; Dragan Ljolje; Luciana Silva-Flannery; Venkatachalam Udhayakumar
Journal:  PLoS One       Date:  2016-03-11       Impact factor: 3.240

4.  Use of Molecular Methods for the Rapid Mass Detection of Schistosoma mansoni (Platyhelminthes: Trematoda) in Biomphalaria spp. (Gastropoda: Planorbidae).

Authors:  Roberta Lima Caldeira; Liana Konovaloffi Jannotti-Passos; Omar Dos Santos Carvalho
Journal:  J Trop Med       Date:  2017-01-26

5.  Development of Colorimetric Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Detecting Feline Coronavirus.

Authors:  Witsanu Rapichai; Wichayet Saejung; Kotchaporn Khumtong; Chaiwat Boonkaewwan; Supansa Tuanthap; Peter A Lieberzeit; Kiattawee Choowongkomon; Jatuporn Rattanasrisomporn
Journal:  Animals (Basel)       Date:  2022-08-14       Impact factor: 3.231

6.  Improved visual detection of DNA amplification using pyridylazophenol metal sensing dyes.

Authors:  Yinhua Zhang; Eric A Hunt; Esta Tamanaha; Ivan R Corrêa; Nathan A Tanner
Journal:  Commun Biol       Date:  2022-09-21

Review 7.  Application of Aptamer-Based Biosensor for Rapid Detection of Pathogenic Escherichia coli.

Authors:  Yu-Wen Zhao; Hai-Xia Wang; Guang-Cheng Jia; Zheng Li
Journal:  Sensors (Basel)       Date:  2018-08-01       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.