| Literature DB >> 24423568 |
Kenichi Tanabe1, Sadako Nakamura2, Tsuneyuki Oku3.
Abstract
We wished to clarify the inaccuracy of AOAC method 2009.01 for the measurement of non-digestible oligosaccharides and to propose an improved method using porcine intestinal enzymes. Amyloglucosidase used in AOAC method 2009.01 scarcely hydrolyses sucrose, palatinose and panose (which are readily digested by intestinal enzymes). Hence, oligosaccharides could not be measured accurately by AOAC method 2009.01. To confirm the inaccuracy of the method, we used porcine intestinal enzymes instead of amyloglucosidase. Using the improved method, fructooligosaccharide and galactooligosaccharide were measured accurately as non-digestible oligosaccharides, but sucrose, palatinose, panose and isomaltooligosaccharide were not. The improved method hydrolysed digestible oligosaccharides into monosaccharides. These results demonstrate that the inaccuracy of AOAC method 2009.01 for oligosaccharide measurement is due to incomplete hydrolysis by amyloglucosidase. We propose that amyloglucosidase should be replaced with porcine intestinal enzymes for such measurements.Entities:
Keywords: AOAC method 2009.01; Accuracy quantitation method; Amyloglucosidase; Non-digestible oligosaccharide; Porcine intestinal enzymes
Mesh:
Substances:
Year: 2013 PMID: 24423568 DOI: 10.1016/j.foodchem.2013.11.121
Source DB: PubMed Journal: Food Chem ISSN: 0308-8146 Impact factor: 7.514