Literature DB >> 24423386

Development and validation of a liquid chromatography isotope dilution mass spectrometry method for the reliable quantification of alkylphenols in environmental water samples by isotope pattern deconvolution.

Neus Fabregat-Cabello1, Juan V Sancho1, Andreu Vidal2, Florenci V González2, Antoni Francesc Roig-Navarro3.   

Abstract

We present here a new measurement method for the rapid extraction and accurate quantification of technical nonylphenol (NP) and 4-t-octylphenol (OP) in complex matrix water samples by UHPLC-ESI-MS/MS. The extraction of both compounds is achieved in 30min by means of hollow fiber liquid phase microextraction (HF-LPME) using 1-octanol as acceptor phase, which provides an enrichment (preconcentration) factor of 800. On the other hand we have developed a quantification method based on isotope dilution mass spectrometry (IDMS) and singly (13)C1-labeled compounds. To this end the minimal labeled (13)C1-4-(3,6-dimethyl-3-heptyl)-phenol and (13)C1-t-octylphenol isomers were synthesized, which coelute with the natural compounds and allows the compensation of the matrix effect. The quantification was carried out by using isotope pattern deconvolution (IPD), which permits to obtain the concentration of both compounds without the need to build any calibration graph, reducing the total analysis time. The combination of both extraction and determination techniques have allowed to validate for the first time a HF-LPME methodology at the required levels by legislation achieving limits of quantification of 0.1ngmL(-1) and recoveries within 97-109%. Due to the low cost of HF-LPME and total time consumption, this methodology is ready for implementation in routine analytical laboratories.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alkylphenol; Hollow fiber liquid phase microextraction; Isotope dilution mass spectrometry; Isotope pattern deconvolution; LC–MS/MS; Wastewater analysis

Mesh:

Substances:

Year:  2014        PMID: 24423386     DOI: 10.1016/j.chroma.2013.12.077

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Isotope pattern deconvolution as a successful alternative to calibration curve for application in wastewater-based epidemiology.

Authors:  Jorge Pitarch-Motellón; Lubertus Bijlsma; Juan Vicente Sancho Llopis; Antoni F Roig-Navarro
Journal:  Anal Bioanal Chem       Date:  2021-03-17       Impact factor: 4.142

2.  Prediction, Detection, and Validation of Isotope Clusters in Mass Spectrometry Data.

Authors:  Hendrik Treutler; Steffen Neumann
Journal:  Metabolites       Date:  2016-10-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.