Literature DB >> 24422555

Marginal bone loss evaluation around immediate non-occlusal microthreaded implants placed in fresh extraction sockets in the maxilla: a 3-year study.

José L Calvo-Guirado1,2, Gerardo Gómez-Moreno3, Antonio Aguilar-Salvatierra3, Javier Guardia3, Rafael A Delgado-Ruiz4, Georgios E Romanos5.   

Abstract

OBJECTIVE: To evaluate marginal bone loss over 3 years around immediate microthreaded implants placed in the maxillary anterior/esthetic zone and immediately restored with single crowns.
MATERIAL AND METHODS: Seventy-one implants (with microthreads up to the platform--rough surface body and neck, internal connection and platform switching) were placed in fresh extraction sockets in the maxillary arches of 30 men and 23 women (mean age 37.85 ± 7.09 years, range 27-60). All subjects had at least 3 mm of soft tissue to allow the establishment of adequate biologic width and to reduce bone resorption. Each patient received a provisional restoration immediately after implant placement with slight occlusal contact. Mesial and distal bone height was evaluated using digital radiography on the day following implant placement (baseline) and after 1, 2, and 3 years. Primary stability was measured with resonance frequency analysis.
RESULTS: No implants failed, resulting in a cumulative survival rate of 100% after 3 years. Marginal bone loss from implant collar to bone crest measured at baseline (peri-implant bone defect at the fresh extraction socket) and after 3 years was 0.86 mm ± 0.29 mm. Mesial and distal site crestal bone loss ranged from 3.42 mm ± 1.2 mm at baseline to 3.51 mm ± 1.5 mm after 3 years (P = 0.063) and from 3.38 mm ± 0.9 mm at baseline to 3.49 mm ± 0.9 mm after 3 years, respectively (P = 0.086).
CONCLUSIONS: This prospective study found minimal marginal bone loss and a 100% implant survival rate over the 3-year follow-up for microthreaded immediate implants subjected to immediate non-occlusal loading.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  dental implants; immediate non-occlusal loading; marginal bone loss; microthread; rough surface neck

Mesh:

Year:  2014        PMID: 24422555     DOI: 10.1111/clr.12336

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  7 in total

1.  The influence of thread geometry on implant osseointegration under immediate loading: a literature review.

Authors:  Hyo-Sook Ryu; Cheol Namgung; Jong-Ho Lee; Young-Jun Lim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

2.  Postextractive implants in aesthetic areas: evaluation of perimplant bone remodeling over time.

Authors:  Michele Mario Figliuzzi; Amerigo Giudice; Maria Giulia Cristofaro; Delfina Pacifico; Pasquale Biamonte; Leonzio Fortunato
Journal:  Ann Stomatol (Roma)       Date:  2015-05-18

3.  Evaluation of a New Dental Implant Cervical Design in Comparison with a Conventional Design in an Experimental American Foxhound Model.

Authors:  Maria Ángeles Pérez-Albacete Martínez; Carlos Pérez-Albacete Martínez; José Eduardo Maté Sánchez De Val; María Luisa Ramos Oltra; Manuel Fernández Domínguez; Jose Luis Calvo Guirado
Journal:  Materials (Basel)       Date:  2018-03-21       Impact factor: 3.623

4.  Esthetic aspects in implant-prosthetic rehabilitation.

Authors:  Norina Forna; Doriana Agop-Forna
Journal:  Med Pharm Rep       Date:  2019-12-15

5.  Survival rates and bone loss after immediate loading of implants in fresh extraction sockets (single gaps). A clinical prospective study with 4 year follow-up.

Authors:  E Velasco-Ortega; E Wojtovicz; A España-Lopez; A Jimenez-Guerra; L Monsalve-Guil; I Ortiz-Garcia; M-A Serrera-Figallo
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2018-03-01

6.  Trabeculae microstructure parameters serve as effective predictors for marginal bone loss of dental implant in the mandible.

Authors:  Hengguo Zhang; Jie Shan; Ping Zhang; Xin Chen; Hongbing Jiang
Journal:  Sci Rep       Date:  2020-10-28       Impact factor: 4.379

7.  Immediate Implant Placement in the Maxillary Aesthetic Zone: A Cone Beam Computed Tomography Study.

Authors:  Anna Botermans; Anna Lidén; Vinícius de Carvalho Machado; Bruno Ramos Chrcanovic
Journal:  J Clin Med       Date:  2021-12-14       Impact factor: 4.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.