Effective point of measurement for parallel plate and cylindrical ion chambers in megavoltage electron beams.

Philip von Voigts-Rhetz1, Damian Czarnecki2, Klemens Zink3.   

Abstract

The presence of an air filled ionization chamber in a surrounding medium introduces several fluence perturbations in high energy photon and electron beams which have to be accounted for. One of these perturbations, the displacement effect, may be corrected in two different ways: by a correction factor pdis or by the application of the concept of the effective point of measurement (EPOM). The latter means, that the volume averaged ionization within the chamber is not reported to the chambers reference point but to a point within the air filled cavity. Within this study the EPOM was determined for four different parallel plate and two cylindrical chambers in megavoltage electron beams using Monte Carlo simulations. The positioning of the chambers with this EPOM at the depth of measurement results in a largely depth independent residual perturbation correction, which is determined within this study for the first time. For the parallel plate chambers the EPOM is independent of the energy of the primary electrons. Whereas for the Advanced Markus chamber the position of the EPOM coincides with the chambers reference point, it is shifted for the other parallel plate chambers several tenths of millimeters downstream the beam direction into the air filled cavity. For the cylindrical chambers there is an increasing shift of the EPOM with increasing electron energy. This shift is in upstream direction, i.e. away from the chambers reference point toward the focus. For the highest electron energy the position of the calculated EPOM is in fairly good agreement with the recommendation given in common dosimetry protocols, for the smallest energy, the calculated EPOM positions deviate about 30% from this recommendation.
Copyright © 2014. Published by Elsevier GmbH.

Entities:  

Keywords:  Elektronendosimetrie; Ionisationskammer; Monte Carlo simulations; Monte-Carlo-Simulation; effective point of measurement; effektiver Messort; electron dosimetry; ionization chambers

Mesh:

Year:  2014        PMID: 24418322     DOI: 10.1016/j.zemedi.2013.12.001

Source DB:  PubMed          Journal:  Z Med Phys        ISSN: 0939-3889            Impact factor:   4.820


  2 in total

1.  Pixel Image Analysis and Its Application with an Alcohol-Based Liquid Scintillator for Particle Therapy.

Authors:  Ji-Won Choi; Ji-Young Choi; Hanil Jang; Kyung-Kwang Joo; Byoung-Chan Kim
Journal:  Sensors (Basel)       Date:  2022-06-28       Impact factor: 3.847

2.  The use of 0.5rcav as an effective point of measurement for cylindrical chambers may result in a systematic shift of electron percentage depth doses.

Authors:  Princess C Anusionwu; Jorge E Alpuche Aviles; Stephen Pistorius
Journal:  J Appl Clin Med Phys       Date:  2020-01-03       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.