Literature DB >> 24418127

Accurate determination of ultra-trace levels of Ti in blood serum using ICP-MS/MS.

Lieve Balcaen1, Eduardo Bolea-Fernandez2, Martín Resano3, Frank Vanhaecke4.   

Abstract

Ti is frequently used in implants and prostheses and it has been shown before that the presence of these in the human body can lead to elevated Ti concentrations in body fluids such as serum and urine. As identification of the exact mechanisms responsible for this increase in Ti concentrations, and the risks associated with it, are not fully understood, it is important to have sound analytical methods that enable straightforward quantification of Ti levels in body fluids (for both implanted and non-implanted individuals). Until now, only double-focusing sector field ICP-mass spectrometry (SF-ICP-MS) offered limits of detection that are good enough to deal with the very low basal levels of Ti in human serum. This work reports on the development of a novel method for the accurate and precise determination of trace levels of Ti in human serum samples, based on the use of ICP-MS/MS. O2 and NH3/He have been compared as reaction gases. While the use of O2 did not enable to overcome all spectral interferences, it has been shown that conversion of Ti(+) ions into Ti(NH3)6(+) cluster ions by using NH3/He as a reaction gas in an ICP-QQQ-MS system, operated in MS/MS mode, provided interference-free conditions and sufficiently low limits of detection, down to 3 ng L(-1) (instrumental detection limit obtained for the most abundant Ti isotope). The accuracy of the method proposed was evaluated by analysis of a Seronorm Trace Elements Serum L-1 reference material and by comparing the results obtained with those achieved by means of SF-ICP-MS. As a proof-of-concept, the newly developed method was successfully applied to the determination of Ti in serum samples obtained from individuals with and without Ti-based implants. All results were found to be in good agreement with those obtained by means of SF-ICP-MS. The typical basal Ti level in human serum was found to be <1 μg L(-1), while values in the range of 2-6 μg L(-1) were observed for implanted patients.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Blood serum; Implants; Reaction cell inductively coupled plasma mass spectrometry; Titanium

Mesh:

Substances:

Year:  2013        PMID: 24418127     DOI: 10.1016/j.aca.2013.10.017

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  9 in total

1.  The distribution of Mn2+ in rabbit eyes after topical administration for manganese-enhanced MRI.

Authors:  Shenzhi Liang; Miao Liang; Yu Zhu; Jingliang Cheng; Zitao Yang
Journal:  Int J Clin Exp Pathol       Date:  2015-01-01

2.  Gastrointestinal Absorption and Toxicity of Nanoparticles and Microparticles: Myth, Reality and Pitfalls explored through Titanium Dioxide.

Authors:  Alessandra Barreto da Silva; Michelle Miniter; William Thom; Rachel E Hewitt; John Wills; Ravin Jugdaohsingh; Jonathan J Powell
Journal:  Curr Opin Toxicol       Date:  2020-02-28

3.  Distribution and predictors of 20 toxic and essential metals in the umbilical cord blood of Chinese newborns.

Authors:  Monica K Silver; Aubrey L Arain; Jie Shao; Minjian Chen; Yankai Xia; Betsy Lozoff; John D Meeker
Journal:  Chemosphere       Date:  2018-07-24       Impact factor: 7.086

4.  Contribution of trace element exposure to gestational diabetes mellitus through disturbing the gut microbiome.

Authors:  Yuqing Zhang; Ting Chen; Yiyun Zhang; Qi Hu; Xu Wang; Hang Chang; Jian-Hua Mao; Antoine M Snijders; Yankai Xia
Journal:  Environ Int       Date:  2021-03-25       Impact factor: 13.352

5.  Utilization of triangle nanosilver to prepare spherical nanosilver and quantitatively detect trace titanium by SERS.

Authors:  Qingye Liu; Guiqing Wen; Xinghui Zhang; Aihui Liang; Zhiliang Jiang
Journal:  Nanoscale Res Lett       Date:  2014-12-10       Impact factor: 4.703

6.  Microelement composition of serum in Dolgans, indigenous inhabitants of the Russian Arctic, in the conditions of industrial development of territories.

Authors:  A I Sivtseva; E N Sivtseva; S S Shadrina; V N Melnikov; S I Boyakova; A M Dokhunaeva
Journal:  Int J Circumpolar Health       Date:  2020-12       Impact factor: 1.228

Review 7.  Latest Trends in Surface Modification for Dental Implantology: Innovative Developments and Analytical Applications.

Authors:  Francesca Accioni; Juan Vázquez; Manuel Merinero; Belén Begines; Ana Alcudia
Journal:  Pharmaceutics       Date:  2022-02-21       Impact factor: 6.321

8.  Analysis of Ti- and Pb-based particles in the aqueous environment of Melbourne (Australia) via single particle ICP-MS.

Authors:  Raquel Gonzalez de Vega; Thomas E Lockwood; Xiaoxue Xu; Claudia Gonzalez de Vega; Johannes Scholz; Maximilian Horstmann; Philip A Doble; David Clases
Journal:  Anal Bioanal Chem       Date:  2022-04-28       Impact factor: 4.478

9.  Release of titanium after insertion of dental implants with different surface characteristics - an ex vivo animal study.

Authors:  Mattias Pettersson; Jean Pettersson; Margareta Molin Thorén; Anders Johansson
Journal:  Acta Biomater Odontol Scand       Date:  2017-11-14
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.