Properties of axially loaded implant-abutment assemblies using digital holographic interferometry analysis.

Juraj Brozović1, Nazif Demoli2, Nina Farkaš3, Mato Sušić4, Zeljko Alar5, Dragana Gabrić Pandurić4.   

Abstract

OBJECTIVE: The aim of this study was to (i) obtain the force-related interferometric patterns of loaded dental implant-abutment assemblies differing in diameter and brand using digital holographic interferometry (DHI) and (ii) determine the influence of implant diameter on the extent of load-induced implant deformation by quantifying and comparing the obtained interferometric data.
METHODS: Experiments included five implant brands (Ankylos, Astra Tech, blueSKY, MIS and Straumann), each represented by a narrow and a wide diameter implant connected to a corresponding abutment. A quasi-Fourier setup with a 25mW helium-neon laser was used for interferometric measurements in the cervical 5mm of the implants. Holograms were recorded in two conditions per measurement: a 10N preloaded and a measuring-force loaded assembly, resulting with an interferogram. This procedure was repeated throughout the whole process of incremental axial loading, from 20N to 120N. Each measurement series was repeated three times for each assembly, with complete dismantling of the implant-loading device in between. Additional software analyses calculated deformation data. Deformations were presented as mean values±standard deviations. Statistical analysis was performed using linear mixed effects modeling in R's lme4 package.
RESULTS: Implants exhibited linear deformation patterns. The wide diameter group had lower mean deformation values than the narrow diameter group. The diameter significantly affected the deformation throughout loading sessions. SIGNIFICANCE: This study gained in vitro implant performance data, compared the deformations in implant bodies and numerically stated the biomechanical benefits of wider diameter implants.
Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biomechanics; Dental implants; Dental implant–abutment design; Dental material; Dental stress analysis; Interferometry; Loading; Materials testing

Mesh:

Substances:

Year:  2014        PMID: 24411994     DOI: 10.1016/j.dental.2013.12.005

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  1 in total

1.  Finite Element Analysis of Stress in Bone and Abutment-Implant Interface under Static and Cyclic Loadings.

Authors:  Saeed Nokar; Hamid Jalali; Farideh Nozari; Mahnaz Arshad
Journal:  Front Dent       Date:  2020-09-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.