Literature DB >> 24409394

Tuning of successively scanned two monolithic Vernier-tuned lasers and selective data sampling in optical comb swept source optical coherence tomography.

Dong-Hak Choi1, Reiko Yoshimura1, Kohji Ohbayashi2.   

Abstract

Monolithic Vernier tuned super-structure grating distributed Bragg reflector (SSG-DBR) lasers are expected to become one of the most promising sources for swept source optical coherence tomography (SS-OCT) with a long coherence length, reduced sensitivity roll-off, and potential capability for a very fast A-scan rate. However, previous implementations of the lasers suffer from four main problems: 1) frequencies deviate from the targeted values when scanned, 2) large amounts of noise appear associated with abrupt changes in injection currents, 3) optically aliased noise appears due to a long coherence length, and 4) the narrow wavelength coverage of a single chip limits resolution. We have developed a method of dynamical frequency tuning, a method of selective data sampling to eliminate current switching noise, an interferometer to reduce aliased noise, and an excess-noise-free connection of two serially scanned lasers to enhance resolution to solve these problems. An optical frequency comb SS-OCT system was achieved with a sensitivity of 124 dB and a dynamic range of 55-72 dB that depended on the depth at an A-scan rate of 3.1 kHz with a resolution of 15 μm by discretely scanning two SSG-DBR lasers, i.e., L-band (1.560-1.599 μm) and UL-band (1.598-1.640 μm). A few OCT images with excellent image penetration depth were obtained.

Entities:  

Keywords:  (170.3880) Medical and biological imaging; (170.4470) Ophthalmology; (170.4500) Optical coherence tomography

Year:  2013        PMID: 24409394      PMCID: PMC3862148          DOI: 10.1364/BOE.4.002962

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  24 in total

1.  Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second.

Authors:  Wolfgang Wieser; Benjamin R Biedermann; Thomas Klein; Christoph M Eigenwillig; Robert Huber
Journal:  Opt Express       Date:  2010-07-05       Impact factor: 3.894

2.  Optical frequency-domain reflectometry with a rapid wavelength-scanning superstructure-grating distributed Bragg reflector laser.

Authors:  Takuji Amano; Hideaki Hiro-Oka; DongHak Choi; Hiroyuki Furukawa; Fumiyoshi Kano; Mituo Takeda; Motoi Nakanishi; Kimiya Shimizu; Kohji Ohbayashi
Journal:  Appl Opt       Date:  2005-02-10       Impact factor: 1.980

3.  Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source.

Authors:  Michael A Choma; Kevin Hsu; Joseph A Izatt
Journal:  J Biomed Opt       Date:  2005 Jul-Aug       Impact factor: 3.170

4.  115 kHz tuning repetition rate ultrahigh-speed wavelength-swept semiconductor laser.

Authors:  W Y Oh; S H Yun; G J Tearney; B E Bouma
Journal:  Opt Lett       Date:  2005-12-01       Impact factor: 3.776

5.  Performance of fourier domain vs. time domain optical coherence tomography.

Authors:  R Leitgeb; C Hitzenberger; Adolf Fercher
Journal:  Opt Express       Date:  2003-04-21       Impact factor: 3.894

6.  Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles.

Authors:  R Huber; M Wojtkowski; K Taira; J Fujimoto; K Hsu
Journal:  Opt Express       Date:  2005-05-02       Impact factor: 3.894

7.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

8.  Frequency comb swept lasers.

Authors:  Tsung-Han Tsai; Chao Zhou; Desmond C Adler; James G Fujimoto
Journal:  Opt Express       Date:  2009-11-09       Impact factor: 3.894

9.  >400 kHz repetition rate wavelength-swept laser and application to high-speed optical frequency domain imaging.

Authors:  Wang-Yuhl Oh; Benjamin J Vakoc; Milen Shishkov; Guillermo J Tearney; Brett E Bouma
Journal:  Opt Lett       Date:  2010-09-01       Impact factor: 3.776

10.  Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second.

Authors:  Benjamin Potsaid; Bernhard Baumann; David Huang; Scott Barry; Alex E Cable; Joel S Schuman; Jay S Duker; James G Fujimoto
Journal:  Opt Express       Date:  2010-09-13       Impact factor: 3.894