| Literature DB >> 24409382 |
Juan Aguirre1, Alexia Giannoula1, Taisuke Minagawa1, Lutz Funk2, Pau Turon2, Turgut Durduran1.
Abstract
A model based reconstruction algorithm that exploits translational symmetries for photoacoustic microscopy to drastically reduce the memory cost is presented. The memory size needed to store the model matrix is independent of the number of acquisitions at different positions. This helps us to overcome one of the main limitations of previous algorithms. Furthermore, using the algebraic reconstruction technique and building the model matrix "on the fly", we have obtained fast reconstructions of simulated and experimental data on both two- and three-dimensional grids using a traditional dark field photoacoustic microscope and a standard personal computer.Keywords: (100.3010) Image reconstruction techniques; (110.5120) Photoacoustic imaging
Year: 2013 PMID: 24409382 PMCID: PMC3862162 DOI: 10.1364/BOE.4.002813
Source DB: PubMed Journal: Biomed Opt Express ISSN: 2156-7085 Impact factor: 3.732