Literature DB >> 24404078

A novel μ-fluidic whole blood coagulation assay based on Rayleigh surface-acoustic waves as a point-of-care method to detect anticoagulants.

Sascha Meyer Dos Santos1, Anita Zorn1, Zeno Guttenberg2, Bettina Picard-Willems1, Christina Kläffling3, Karen Nelson4, Ute Klinkhardt1, Sebastian Harder1.   

Abstract

A universal coagulation test that reliably detects prolonged coagulation time in patients, irrespective of the anticoagulant administered, has not been available to date. An easily miniaturised, novel μ-fluidic universal coagulation test employing surface acoustic waves (SAW) is presented here. SAW was employed to instantly mix and recalcify 6 μl citrated whole blood and image correlation analysis was used to quantify clot formation kinetics. The detection of clinically relevant anticoagulant dosing with old anticoagulants (unfractionated heparin, argatroban) and new anticoagulants (dabigatran, rivaroxaban) has been tested and compared to standard plasma coagulation assays. The applicability of this novel method has been confirmed in a small patient population. Coagulation was dose-proportionally prolonged with heparin, argatroban, dabigatran, and rivaroxaban, comparable to standard tests. Aspirin and clopidogrel did not interfere with the SAW-induced clotting time (SAW-CT), whereas the strong GPIIb/IIIa-inhibitor abciximab did interfere. Preliminary clinical data prove the suitability of the SAW-CT in patients being treated with warfarin, rivaroxaban, or dabigatran. The system principally allows assessment of whole blood coagulation in humans in a point-of-care setting. This method could be used in stroke units, emergency vehicles, general and intensive care wards, as well as for laboratory and home testing of coagulation.

Entities:  

Year:  2013        PMID: 24404078      PMCID: PMC3799685          DOI: 10.1063/1.4824043

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  59 in total

Review 1.  Global haemostasis assays, from bench to bedside.

Authors:  Mark van Geffen; Waander L van Heerde
Journal:  Thromb Res       Date:  2012-01-04       Impact factor: 3.944

Review 2.  Considerations in the laboratory assessment of haemostasis.

Authors:  A McCraw; A Hillarp; M Echenagucia
Journal:  Haemophilia       Date:  2010-07       Impact factor: 4.287

3.  Planar chip device for PCR and hybridization with surface acoustic wave pump.

Authors:  Zeno Guttenberg; Helena Muller; Heiko Habermüller; Andreas Geisbauer; Jürgen Pipper; Jana Felbel; Mark Kielpinski; Jürgen Scriba; Achim Wixforth
Journal:  Lab Chip       Date:  2004-12-16       Impact factor: 6.799

4.  Surface acoustic wave concentration of particle and bioparticle suspensions.

Authors:  Haiyan Li; James R Friend; Leslie Y Yeo
Journal:  Biomed Microdevices       Date:  2007-10       Impact factor: 2.838

5.  Microfluidic mixing via acoustically driven chaotic advection.

Authors:  Thomas Frommelt; Marcin Kostur; Melanie Wenzel-Schäfer; Peter Talkner; Peter Hänggi; Achim Wixforth
Journal:  Phys Rev Lett       Date:  2008-01-24       Impact factor: 9.161

6.  Whole blood pumping with a microthrottle pump.

Authors:  M J Davies; I D Johnston; C K L Tan; M C Tracey
Journal:  Biomicrofluidics       Date:  2010-12-23       Impact factor: 2.800

7.  Method for the determination of functional (clottable) fibrinogen by the new family of ACL coagulometers.

Authors:  E Rossi; P Mondonico; A Lombardi; L Preda
Journal:  Thromb Res       Date:  1988-12-01       Impact factor: 3.944

8.  Safety, pharmacodynamics, and pharmacokinetics of single doses of BAY 59-7939, an oral, direct factor Xa inhibitor.

Authors:  Dagmar Kubitza; Michael Becka; Barbara Voith; Michael Zuehlsdorf; Georg Wensing
Journal:  Clin Pharmacol Ther       Date:  2005-10       Impact factor: 6.875

9.  Safety, tolerability, pharmacodynamics, and pharmacokinetics of rivaroxaban--an oral, direct factor Xa inhibitor--are not affected by aspirin.

Authors:  Dagmar Kubitza; Michael Becka; Wolfgang Mueck; Michael Zuehlsdorf
Journal:  J Clin Pharmacol       Date:  2006-09       Impact factor: 3.126

10.  Red blood cells: their dual role in thrombus formation.

Authors:  V T Turitto; H J Weiss
Journal:  Science       Date:  1980-02-01       Impact factor: 47.728

View more
  10 in total

1.  On-chip recalcification of citrated whole blood using a microfluidic herringbone mixer.

Authors:  Marcus Lehmann; Alison M Wallbank; Kimberly A Dennis; Adam R Wufsus; Kara M Davis; Kuldeepsinh Rana; Keith B Neeves
Journal:  Biomicrofluidics       Date:  2015-11-18       Impact factor: 2.800

2.  Migration distance-based platelet function analysis in a microfluidic system.

Authors:  Suk-Heung Song; Chae-Seung Lim; Sehyun Shin
Journal:  Biomicrofluidics       Date:  2013-11-04       Impact factor: 2.800

Review 3.  Laboratory Assessment of the Anticoagulant Activity of Direct Oral Anticoagulants: A Systematic Review.

Authors:  Bethany T Samuelson; Adam Cuker; Deborah M Siegal; Mark Crowther; David A Garcia
Journal:  Chest       Date:  2016-09-13       Impact factor: 9.410

4.  Engineering a simple lateral flow device for animal blood coagulation monitoring.

Authors:  Hua Li; Daewoo Han; Giovanni M Pauletti; Andrew J Steckl
Journal:  Biomicrofluidics       Date:  2018-01-23       Impact factor: 2.800

5.  A droplet-based microfluidic viscometer for the measurement of blood coagulation.

Authors:  Sarah E Mena; Yunzi Li; Joseph McCormick; Brendan McCracken; Carmen Colmenero; Kevin Ward; Mark A Burns
Journal:  Biomicrofluidics       Date:  2020-01-17       Impact factor: 2.800

6.  Real-time measurement of thrombin generation using continuous droplet microfluidics.

Authors:  Jiaqing Yu; Ding Tao; Ee Xing Ng; Chester L Drum; Ai Qun Liu; Chia-Hung Chen
Journal:  Biomicrofluidics       Date:  2014-09-03       Impact factor: 2.800

7.  Visualization of Surface Acoustic Waves in Thin Liquid Films.

Authors:  R W Rambach; J Taiber; C M L Scheck; C Meyer; J Reboud; J M Cooper; T Franke
Journal:  Sci Rep       Date:  2016-02-26       Impact factor: 4.379

8.  ZnO Film Bulk Acoustic Resonator for the Kinetics Study of Human Blood Coagulation.

Authors:  Da Chen; Zhen Zhang; Jilong Ma; Wei Wang
Journal:  Sensors (Basel)       Date:  2017-05-03       Impact factor: 3.576

Review 9.  Evolving Paradigm of Prothrombin Time Diagnostics with Its Growing Clinical Relevance towards Cardio-Compromised and COVID-19 Affected Population.

Authors:  Anubhuti Saha; Ashutosh Bajpai; Vinay Krishna; Shantanu Bhattacharya
Journal:  Sensors (Basel)       Date:  2021-04-09       Impact factor: 3.576

10.  A Pumpless Microfluidic Neonatal Lung Assist Device for Support of Preterm Neonates in Respiratory Distress.

Authors:  Mohammadhossein Dabaghi; Niels Rochow; Neda Saraei; Gerhard Fusch; Shelley Monkman; Kevin Da; Alireza Shahin-Shamsabadi; John L Brash; Dragos Predescu; Kathleen Delaney; Christoph Fusch; P Ravi Selvaganapathy
Journal:  Adv Sci (Weinh)       Date:  2020-09-29       Impact factor: 16.806

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.