Literature DB >> 24404025

Direct detection of cancer biomarkers in blood using a "place n play" modular polydimethylsiloxane pump.

Honglian Zhang1, Gang Li1, Lingying Liao1, Hongju Mao1, Qinghui Jin1, Jianlong Zhao1.   

Abstract

Cancer biomarkers have significant potential as reliable tools for the early detection of the disease and for monitoring its recurrence. However, most current methods for biomarker detection have technical difficulties (such as sample preparation and specific detector requirements) which limit their application in point of care diagnostics. We developed an extremely simple, power-free microfluidic system for direct detection of cancer biomarkers in microliter volumes of whole blood. CEA and CYFRA21-1 were chosen as model cancer biomarkers. The system automatically extracted blood plasma from less than 3 μl of whole blood and performed a multiplex sample-to-answer assay (nano-ELISA (enzyme-linked immunosorbent assay) technique) without the use of external power or extra components. By taking advantage of the nano-ELISA technique, this microfluidic system detected CEA at a concentration of 50 pg/ml and CYFRA21-1 at a concentration of 60 pg/ml within 60 min. The combination of PnP polydimethylsiloxane (PDMS) pump and nano-ELISA technique in a single microchip system shows great promise for the detection of cancer biomarkers in a drop of blood.

Entities:  

Year:  2013        PMID: 24404025      PMCID: PMC3676392          DOI: 10.1063/1.4807803

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  40 in total

1.  Power-free poly(dimethylsiloxane) microfluidic devices for gold nanoparticle-based DNA analysis.

Authors:  Kazuo Hosokawa; Kae Sato; Naoki Ichikawa; Mizuo Maeda
Journal:  Lab Chip       Date:  2004-05-12       Impact factor: 6.799

2.  Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications.

Authors:  Timothy A Crowley; Vincent Pizziconi
Journal:  Lab Chip       Date:  2005-07-19       Impact factor: 6.799

3.  Paramagnetic capture mode magnetophoretic microseparator for high efficiency blood cell separations.

Authors:  Ki-Ho Han; A Bruno Frazier
Journal:  Lab Chip       Date:  2005-12-19       Impact factor: 6.799

4.  Dielectrophoresis has broad applicability to marker-free isolation of tumor cells from blood by microfluidic systems.

Authors:  Sangjo Shim; Katherine Stemke-Hale; Jamileh Noshari; Frederick F Becker; Peter R C Gascoyne
Journal:  Biomicrofluidics       Date:  2013-01-16       Impact factor: 2.800

5.  Continual collection and re-separation of circulating tumor cells from blood using multi-stage multi-orifice flow fractionation.

Authors:  Hui-Sung Moon; Kiho Kwon; Kyung-A Hyun; Tae Seok Sim; Jae Chan Park; Jeong-Gun Lee; Hyo-Il Jung
Journal:  Biomicrofluidics       Date:  2013-01-24       Impact factor: 2.800

6.  Carcinoembryonic antigen in patients with different cancers.

Authors:  G Reynoso; T M Chu; D Holyoke; E Cohen; T Nemoto; J J Wang; J Chuang; P Guinan; G P Murphy
Journal:  JAMA       Date:  1972-04-17       Impact factor: 56.272

7.  Size-selective microcavity array for rapid and efficient detection of circulating tumor cells.

Authors:  Masahito Hosokawa; Taishi Hayata; Yorikane Fukuda; Atsushi Arakaki; Tomoko Yoshino; Tsuyoshi Tanaka; Tadashi Matsunaga
Journal:  Anal Chem       Date:  2010-08-01       Impact factor: 6.986

8.  Rapid and sensitive chemiluminescent enzyme immunoassay for measuring tumor markers.

Authors:  I Nishizono; S Iida; N Suzuki; H Kawada; H Murakami; Y Ashihara; M Okada
Journal:  Clin Chem       Date:  1991-09       Impact factor: 8.327

9.  Whole blood samples as an alternative to serum for detection of immunity to measles virus by ELISA.

Authors:  A Chakravarti; D Rawat; Sangita Yadav
Journal:  Diagn Microbiol Infect Dis       Date:  2003-12       Impact factor: 2.803

10.  The application of current diagnostic protocols of patients with colon cancer in preparation for therapy.

Authors:  Zora Vukobrat-Bijedic; Azra Husic-Selimovic; Amela Sofic; Nina Bijedic; Bisera Gogov; Aleksandra Djuran; Amila Redzepovic; Aida Saray; Ivana Bjelogrlic
Journal:  Acta Inform Med       Date:  2012-12
View more
  3 in total

1.  Microfluidic rectifier based on poly(dimethylsiloxane) membrane and its application to a micropump.

Authors:  Yao-Nan Wang; Chien-Hsiung Tsai; Lung-Ming Fu; Lung-Kai Lin Liou
Journal:  Biomicrofluidics       Date:  2013-08-14       Impact factor: 2.800

2.  A Novel Microfluidic Device for Blood Plasma Filtration.

Authors:  Zaidon T Al-Aqbi; Salim Albukhaty; Ameerah M Zarzoor; Ghassan M Sulaiman; Khalil A A Khalil; Tareg Belali; Mohamed T A Soliman
Journal:  Micromachines (Basel)       Date:  2021-03-22       Impact factor: 2.891

3.  A power-free, parallel loading microfluidic reactor array for biochemical screening.

Authors:  Yanwu Liu; Gang Li
Journal:  Sci Rep       Date:  2018-09-12       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.