The validity of inclinometer measurements by ActiGraph GT3X+ (AG) accelerometer, when analysed with the Acti4 customised software, was examined by comparison of inclinometer measurements with a reference system (TrakStar) in a protocol with standardised arm movements and simulated working tasks. The sensors were placed at the upper arm (distal to the deltoid insertion) and at the spine (level of T1-T2) on eight participants. Root mean square errors (RMSEs) values of inclination between the two systems were low for the slow- and medium-speed standardised arm movements and in simulated working tasks. Fast arm movements caused the inclination estimated by the AG to deviate from the reference measurements (RMSE values up to ∼10°). Furthermore, it was found that AG positioned at the upper arm provided inclination data without bias compared to the reference system. These findings indicate that the AG provides valid estimates of arm and upper body inclination in working participants. PRACTITIONER SUMMARY: Being inexpensive, small, water-resistant and without wires, ActiGraph GT3X+ seems to be a valid mean for direct long-term field measurements of arm and trunk inclinations when analysed by the Acti4 customised software.
The validity of inclinometer measurements by ActiGraph GT3X+ (AG) accelerometer, when analysed with the Acti4 customised software, was examined by comparison of inclinometer measurements with a reference system (TrakStar) in a protocol with standardised arm movements and simulated working tasks. The sensors were placed at the upper arm (distal to the deltoid insertion) and at the spine (level of T1-T2) on eight participants. Root mean square errors (RMSEs) values of inclination between the two systems were low for the slow- and medium-speed standardised arm movements and in simulated working tasks. Fast arm movements caused the inclination estimated by the AG to deviate from the reference measurements (RMSE values up to ∼10°). Furthermore, it was found that AG positioned at the upper arm provided inclination data without bias compared to the reference system. These findings indicate that the AG provides valid estimates of arm and upper body inclination in working participants. PRACTITIONER SUMMARY: Being inexpensive, small, water-resistant and without wires, ActiGraph GT3X+ seems to be a valid mean for direct long-term field measurements of arm and trunk inclinations when analysed by the Acti4 customised software.
Authors: Mikkel Brandt; Pascal Madeleine; Jeppe Zielinski Nguyen Ajslev; Markus D Jakobsen; Afshin Samani; Emil Sundstrup; Pete Kines; Lars L Andersen Journal: BMC Musculoskelet Disord Date: 2015-10-16 Impact factor: 2.362
Authors: Lars-Kristian Lunde; Markus Koch; Stein Knardahl; Morten Wærsted; Svend Erik Mathiassen; Mikael Forsman; Andreas Holtermann; Kaj Bo Veiersted Journal: BMC Public Health Date: 2014-10-16 Impact factor: 3.295
Authors: David M Hallman; Nidhi Gupta; Marina Heiden; Svend Erik Mathiassen; Mette Korshøj; Marie Birk Jørgensen; Andreas Holtermann Journal: BMJ Open Date: 2016-11-10 Impact factor: 2.692
Authors: David M Hallman; Svend Erik Mathiassen; Nidhi Gupta; Mette Korshøj; Andreas Holtermann Journal: BMC Public Health Date: 2015-09-28 Impact factor: 3.295
Authors: David M Hallman; Svend Erik Mathiassen; Marina Heiden; Nidhi Gupta; Marie Birk Jørgensen; Andreas Holtermann Journal: Int Arch Occup Environ Health Date: 2016-03-02 Impact factor: 3.015