Literature DB >> 24389587

Influence of centrifuge brake on residual platelet count and routine coagulation tests in citrated plasma.

Massimo Daves1, Katia Giacomuzzi, Enrico Tagnin, Erika Jani, Dorothy M Adcock Funk, Emmanuel J Favaloro, Giuseppe Lippi.   

Abstract

Sample centrifugation is an essential step in the coagulation laboratory, as clotting tests are typically performed on citrated platelet (PLT) poor plasma (PPP). Nevertheless, no clear indication has been provided as to whether centrifugation of specimens should be performed with the centrifuge brake set to on or off. Fifty consecutive sodium citrate anticoagulated samples were collected and divided into two aliquots. The former was centrifuged as for Clinical Laboratory Standards Institute (CLSI) guidelines with the centrifuge brake set to on, whereas the latter was centrifuged again as for CLSI guidelines, but with the brake set to off. In the PPP of all samples, a PLT count was performed, followed by the analysis of activated partial thromboplastin time (APTT), prothrombin time (PT) and fibrinogen (FBG). The PLT count after samples centrifugation was substantially reduced, either with centrifuge brake set to on or off (5 ± 1 versus 3 ± 1 × 10/l; P = 0.009). The frequency of samples exceeding a PLT count less than 10 × 10/l was nearly double in samples centrifuged with the brake on than in those with the brake off (14 versus 8%; P < 0.01). Although no significant difference was found for APTT values, PT was slightly prolonged using the centrifuge brake set to on (mean bias 0.2 s; P < 0.001). FBG values were also significantly higher using the centrifuge brake set to on (mean bias 0.29 g/l; P < 0.001). The results of this study indicate that sample centrifugation for routine coagulation testing should be preferably performed with the centrifuge brake set to off for providing a better quality specimen.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24389587     DOI: 10.1097/MBC.0000000000000026

Source DB:  PubMed          Journal:  Blood Coagul Fibrinolysis        ISSN: 0957-5235            Impact factor:   1.276


  4 in total

Review 1.  Pre-analytic variability in cardiovascular biomarker testing.

Authors:  Roberto Cemin; Massimo Daves
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

2.  Does centrifugation matter? Centrifugal force and spinning time alter the plasma metabolome.

Authors:  Dorothea Lesche; Roland Geyer; Daniel Lienhard; Christos T Nakas; Gaëlle Diserens; Peter Vermathen; Alexander B Leichtle
Journal:  Metabolomics       Date:  2016-09-15       Impact factor: 4.290

Review 3.  Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories.

Authors:  A Magnette; M Chatelain; B Chatelain; H Ten Cate; F Mullier
Journal:  Thromb J       Date:  2016-12-12

4.  Profiles of Coagulation and Fibrinolysis Activation-Associated Molecular Markers of Atypical Hemolytic Uremic Syndrome in the Acute Phase.

Authors:  Satoko Sakurai; Hideki Kato; Yoko Yoshida; Yuka Sugawara; Madoka Fujisawa; Atsushi Yasumoto; Masanori Matsumoto; Yoshihiro Fujimura; Yutaka Yatomi; Masaomi Nangaku
Journal:  J Atheroscler Thromb       Date:  2019-09-04       Impact factor: 4.928

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.