Literature DB >> 24387942

Effect of one-off complete tumor radiofrequency ablation on liver function and postoperative complication in small hepatocellular carcinoma.

K Jiang1, J Dong2, W Zhang2, Y Liu2, M Su2, X Zhao2, J Wang2, M Yao3, Z Huang2.   

Abstract

OBJECTIVE: Radiofrequency ablation (RFA) is effective in treating hepatocellular carcinoma (HCC) and less invasive than surgical resection. However, 'one-off' complete tumor ablation on liver function has not been reported.
METHODS: We retrospectively reviewed 36 HCCs which met the criteria of 'one-off' complete tumor ablation: (1) tumor was completed covered by the ablated zone (confirmed by postoperative enhanced CT) with a single RFA and, (2) no sign of recurrence for at least 6 months. We categorized tumors into two groups: near vascular tumor (NVT) if the distance was less than 5 mm, and far vascular tumor (FVT) otherwise.
RESULTS: Thirteen HCCs met the criteria of NVTs, and 23 HCCs met that of FVTs. The Average tumor size was 2.6 ± 0.3 cm in FVTs and 2.5 ± 0.3 cm in NVTs. Although restored to normal range by postoperative day (POD) 7, ALT, AST, total bilirubin (TB), albumin and prothrombin time showed more significant fluctuation in NVTs compared to those in FVTs on POD1 through POD5. Moreover, 53.9% (7/13) patients in NVT group and 26.1% (6/23) in FVT group developed post-RFA transient ascites (OR = 5.1, 95% CI = 1.1-24.4). Incidence of post-RFA pleural effusion were 61.5% (8/13) in NVT but only 17.4% (4/23) in FVTs (OR = 7.6, 95% CI = 1.6-35.9).
CONCLUSION: 'One-off' complete tumor ablation may impair liver function and led to more postoperative complication if a tumor is within 5 mm away from a large blood vessel (≥ 3 mm). Particular caution should be made in preoperative assessment on the anatomic relation between tumor and large blood vessel for patients.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Deep sited tumor; Heat Sink Effect; Large blood vessel; Liver function; Liver parenchyma; One-off complete tumor ablation; Postoperative complication; Radiofrequency ablation; River Flow Effect; Small hepatocellular carcinoma; Superficial tumor

Mesh:

Substances:

Year:  2013        PMID: 24387942     DOI: 10.1016/j.ejso.2013.12.004

Source DB:  PubMed          Journal:  Eur J Surg Oncol        ISSN: 0748-7983            Impact factor:   4.424


  3 in total

1.  Non-invasive magnetic resonance-guided high intensity focused ultrasound ablation of a vascular malformation in the lower extremity: a case report.

Authors:  Johanna M M van Breugel; Robbert J Nijenhuis; Mario G Ries; Raechel J Toorop; Evert-Jan P A Vonken; Joost W Wijlemans; Maurice A A J van den Bosch
Journal:  J Ther Ultrasound       Date:  2015-12-30

2.  Upregulation of PDGF Mediates Robust Liver Regeneration after Nanosecond Pulsed Electric Field Ablation by Promoting the HGF/c-Met Pathway.

Authors:  Junjie Qian; Jianpeng Liu; Liangjie Hong; Haohao Lu; Danjing Guo; Zhen Liu; Lin Zhou; Shengyong Yin; Shusen Zheng
Journal:  Biomed Res Int       Date:  2020-03-14       Impact factor: 3.411

3.  Influence of the heat irrigating effect of radiofrequency ablation on regional liver tissue in Bama miniature pigs.

Authors:  Jian Feng; Song Wang; Kai Jiang
Journal:  World J Gastrointest Oncol       Date:  2021-02-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.