| Literature DB >> 24385139 |
Jacqueline A Fairley1, George Georgoulas2, Chrystostomos D Stylios2, George Vachtsevanos3, David B Rye4, Donald L Bliwise4.
Abstract
The Phasic Electromyographic Metric (PEM) has been recently introduced as a sensitive indicator to differentiate Parkinson's Disease (PD) patients from controls, non-PD patients with a history of Rapid Eye Movement Disorder (RBD) from controls, and PD patients with early and late stage disease. However, PEM assessment through visual inspection is a cumbersome and time consuming process. Therefore, a reliable automated approach is required so as to increase the utilization of PEM as a reliable and efficient clinical tool to track PD progression. In this study an automated method for the detection of PEM is presented, based on the use of signal analysis and pattern recognition techniques. The results are promising indicating that an automatic PEM identification procedure is feasible.Entities:
Year: 2011 PMID: 24385139 PMCID: PMC3873000 DOI: 10.1109/MED.2011.5983202
Source DB: PubMed Journal: Mediterr Conf Control Automation ISSN: 2325-369X