Literature DB >> 24382710

Reproducibility of thoracic and abdominal aortic wall measurements with three-dimensional, variable flip angle (SPACE) MRI.

Georgeta Mihai1, Juliet Varghese, Bo Lu, Hong Zhu, Orlando P Simonetti, Sanjay Rajagopalan.   

Abstract

PURPOSE: To evaluate the reproducibility and repeatability of high-resolution, isotropic thoracic and abdominal aortic wall measurements, and determine the implications they have on the number of subjects necessary for future clinical trials.
MATERIALS AND METHODS: Using a T1-weighted three-dimensional MRI SPACE sequence, we evaluated the interobserver, intraobserver, and scan-rescan variability of isotropic thoracic and abdominal aortic wall measurements in 15 cardiovascular diseased patients and 6 normal volunteers. Main outcome analyses were intracorrelation coefficient (ICC), mean relative error (mRE), and sample size calculation at 80% power to be used to compare placebo group and treatment group means in future two-arm randomized clinical trials.
RESULTS: Excellent reliability, ICC > 0.8 (P < 0.001) and small mRE < 10% were demonstrated for the interobserver, intraobserver, and scan-rescan variability for all investigated measures: lumen area (LA), outer wall area (OWA), wall area (VWA), total wall volume (TWV), and percentage wall volume (%WV). Sample size calculation revealed slightly different sample size per treatment arm for thoracic and abdominal aorta segments (maximum number of subjects: 352 subjects for thoracic segment versus 421 subjects for abdominal segment for LA at 5% difference, and minimum of 3 thoracic versus 4 abdominal subjects needed for %WV evaluation at 25% difference).
CONCLUSION: Our study demonstrates the reproducibility and repeatability of SPACE aortic plaque measurements, and gives insight into the number of subjects needed for the design of therapeutic studies in aortic atherosclerosis.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  aorta; atherosclerosis; clinical trial; magnetic resonance imaging; reproducibility; variable flip angle

Mesh:

Year:  2013        PMID: 24382710     DOI: 10.1002/jmri.24545

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  10 in total

1.  Isotropic 3D black blood MRI of abdominal aortic aneurysm wall and intraluminal thrombus.

Authors:  Chengcheng Zhu; Henrik Haraldsson; Farshid Faraji; Christopher Owens; Warren Gasper; Sinyeob Ahn; Jing Liu; Gerhard Laub; Michael D Hope; David Saloner
Journal:  Magn Reson Imaging       Date:  2015-10-22       Impact factor: 2.546

2.  Assessment of pituitary micro-lesions using 3D sampling perfection with application-optimized contrasts using different flip-angle evolutions.

Authors:  Jing Wang; Yue Wu; Zhenwei Yao; Zhong Yang
Journal:  Neuroradiology       Date:  2014-09-24       Impact factor: 2.804

3.  Reference Values for Cardiac and Aortic Magnetic Resonance Imaging in Healthy, Young Caucasian Adults.

Authors:  Anouk L M Eikendal; Michiel L Bots; Cees Haaring; Tobias Saam; Rob J van der Geest; Jos J M Westenberg; Hester M den Ruijter; Imo E Hoefer; Tim Leiner
Journal:  PLoS One       Date:  2016-10-12       Impact factor: 3.240

Review 4.  Vessel wall characterization using quantitative MRI: what's in a number?

Authors:  Bram F Coolen; Claudia Calcagno; Pim van Ooij; Zahi A Fayad; Gustav J Strijkers; Aart J Nederveen
Journal:  MAGMA       Date:  2017-08-14       Impact factor: 2.310

5.  Feasibility of 3D black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease.

Authors:  Markus Henningsson; Riad Abou Zahr; Adrian Dyer; Gerald F Greil; Barbara Burkhardt; Animesh Tandon; Tarique Hussain
Journal:  J Cardiovasc Magn Reson       Date:  2018-11-26       Impact factor: 5.364

6.  Combined intravenous and intra-articular tranexamic acid administration in total knee arthroplasty for preventing blood loss and hyperfibrinolysis: A randomized controlled trial.

Authors:  Yi-Min Zhang; Bo Yang; Xue-Dong Sun; Zhen Zhang
Journal:  Medicine (Baltimore)       Date:  2019-02       Impact factor: 1.817

7.  Carotid wall imaging with 3D_T2_FFE: sequence parameter optimization and comparison with 3D_T2_SPACE.

Authors:  Ang Yang; Xue Hong Xiao; Zhi Long Wang; Yong Xin Zhang; Ke Yi Wang
Journal:  Sci Rep       Date:  2021-01-26       Impact factor: 4.379

8.  Application of Contrast-Enhanced 3-Dimensional T2-Weighted Volume Isotropic Turbo Spin Echo Acquisition Sequence in the Diagnosis of Prolactin-Secreting Pituitary Microadenomas.

Authors:  Rui Guo; Yue Wu; Guangcheng Guo; Haiyang Zhou; Shoutang Liu; Zhenwei Yao; Yunping Xiao
Journal:  J Comput Assist Tomogr       Date:  2022 Jan-Feb 01       Impact factor: 1.826

9.  3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study.

Authors:  Anouk L M Eikendal; Björn A Blomberg; Cees Haaring; Tobias Saam; Rob J van der Geest; Fredy Visser; Michiel L Bots; Hester M den Ruijter; Imo E Hoefer; Tim Leiner
Journal:  J Cardiovasc Magn Reson       Date:  2016-04-14       Impact factor: 5.364

10.  3D whole-brain vessel wall cardiovascular magnetic resonance imaging: a study on the reliability in the quantification of intracranial vessel dimensions.

Authors:  Na Zhang; Fan Zhang; Zixin Deng; Qi Yang; Marcio A Diniz; Shlee S Song; Konrad H Schlick; M Marcel Maya; Nestor Gonzalez; Debiao Li; Hairong Zheng; Xin Liu; Zhaoyang Fan
Journal:  J Cardiovasc Magn Reson       Date:  2018-06-14       Impact factor: 5.364

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.