Literature DB >> 24382512

Applicability of rat precision-cut lung slices in evaluating nanomaterial cytotoxicity, apoptosis, oxidative stress, and inflammation.

Ursula G Sauer1, Sandra Vogel2, Alexandra Aumann3, Annemarie Hess3, Susanne N Kolle3, Lan Ma-Hock3, Wendel Wohlleben4, Martina Dammann3, Volker Strauss3, Silke Treumann3, Sibylle Gröters3, Karin Wiench5, Bennard van Ravenzwaay3, Robert Landsiedel6.   

Abstract

The applicability of rat precision-cut lung slices (PCLuS) in detecting nanomaterial (NM) toxicity to the respiratory tract was investigated evaluating sixteen OECD reference NMs (TiO₂, ZnO, CeO₂, SiO₂, Ag, multi-walled carbon nanotubes (MWCNTs)). Upon 24-hour test substance exposure, the PCLuS system was able to detect early events of NM toxicity: total protein, reduction in mitochondrial activity, caspase-3/-7 activation, glutathione depletion/increase, cytokine induction, and histopathological evaluation. Ion shedding NMS (ZnO and Ag) induced severe tissue destruction detected by the loss of total protein. Two anatase TiO₂ NMs, CeO₂ NMs, and two MWCNT caused significant (determined by trend analysis) cytotoxicity in the WST-1 assay. At non-cytotoxic concentrations, different TiO₂ NMs and one MWCNT increased GSH levels, presumably a defense response to reactive oxygen species, and these substances further induced a variety of cytokines. One of the SiO₂ NMs increased caspase-3/-7 activities at non-cytotoxic levels, and one rutile TiO₂ only induced cytokines. Investigating these effects is, however, not sufficient to predict apical effects found in vivo. Reproducibility of test substance measurements was not fully satisfactory, especially in the GSH and cytokine assays. Effects were frequently observed in negative controls pointing to tissue slice vulnerability even though prepared and handled with utmost care. Comparisons of the effects observed in the PCLuS to in vivo effects reveal some concordances for the metal oxide NMs, but less so for the MWCNT. The highest effective dosages, however, exceeded those reported for rat short-term inhalation studies. To become applicable for NM testing, the PCLuS system requires test protocol optimization.
Copyright © 2013 the Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cytokines; Cytotoxicity; Histopathology; Nanomaterial (NM); Oxidative stress; Rat precision-cut lung slices (PCLuS)

Mesh:

Substances:

Year:  2013        PMID: 24382512     DOI: 10.1016/j.taap.2013.12.017

Source DB:  PubMed          Journal:  Toxicol Appl Pharmacol        ISSN: 0041-008X            Impact factor:   4.219


  20 in total

Review 1.  Organ-on-a-chip for assessing environmental toxicants.

Authors:  Soohee Cho; Jeong-Yeol Yoon
Journal:  Curr Opin Biotechnol       Date:  2017-01-11       Impact factor: 9.740

Review 2.  The impact of nanomaterial characteristics on inhalation toxicity.

Authors:  Frank S Bierkandt; Lars Leibrock; Sandra Wagener; Peter Laux; Andreas Luch
Journal:  Toxicol Res (Camb)       Date:  2018-02-01       Impact factor: 3.524

3.  Tissue traction microscopy to quantify muscle contraction within precision-cut lung slices.

Authors:  Sumati Ram-Mohan; Yan Bai; Niccole Schaible; Allen J Ehrlicher; Daniel P Cook; Bela Suki; David A Stoltz; Julian Solway; Xingbin Ai; Ramaswamy Krishnan
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2019-11-27       Impact factor: 5.464

4.  Screening for Chemical Toxicity Using Cryopreserved Precision Cut Lung Slices.

Authors:  Christa Y Watson; Flavia Damiani; Sumati Ram-Mohan; Sylvia Rodrigues; Priscila de Moura Queiroz; Thomas C Donaghey; Jamie H Rosenblum Lichtenstein; Joseph D Brain; Ramaswamy Krishnan; Ramon M Molina
Journal:  Toxicol Sci       Date:  2015-12-29       Impact factor: 4.849

Review 5.  Applications and Approaches for Three-Dimensional Precision-Cut Lung Slices. Disease Modeling and Drug Discovery.

Authors:  Hani N Alsafadi; Franziska E Uhl; Ricardo H Pineda; Kolene E Bailey; Mauricio Rojas; Darcy E Wagner; Melanie Königshoff
Journal:  Am J Respir Cell Mol Biol       Date:  2020-06       Impact factor: 6.914

Review 6.  Lung Models to Evaluate Silver Nanoparticles' Toxicity and Their Impact on Human Health.

Authors:  Jesús Gabriel González-Vega; Juan Carlos García-Ramos; Rocio Alejandra Chavez-Santoscoy; Javier Emmanuel Castillo-Quiñones; María Evarista Arellano-Garcia; Yanis Toledano-Magaña
Journal:  Nanomaterials (Basel)       Date:  2022-07-05       Impact factor: 5.719

7.  siRNA-Mediated RNA Interference in Precision-Cut Tissue Slices Prepared from Mouse Lung and Kidney.

Authors:  Mitchel J R Ruigrok; Nalinie Maggan; Delphine Willaert; Henderik W Frijlink; Barbro N Melgert; Peter Olinga; Wouter L J Hinrichs
Journal:  AAPS J       Date:  2017-09-11       Impact factor: 4.009

8.  Proinflammatory and cytotoxic response to nanoparticles in precision-cut lung slices.

Authors:  Stephanie Hirn; Nadine Haberl; Kateryna Loza; Matthias Epple; Wolfgang G Kreyling; Barbara Rothen-Rutishauser; Markus Rehberg; Fritz Krombach
Journal:  Beilstein J Nanotechnol       Date:  2014-12-18       Impact factor: 3.649

9.  Comparative lung toxicity of engineered nanomaterials utilizing in vitro, ex vivo and in vivo approaches.

Authors:  Yong Ho Kim; Elizabeth Boykin; Tina Stevens; Katelyn Lavrich; M Ian Gilmour
Journal:  J Nanobiotechnology       Date:  2014-11-26       Impact factor: 10.435

Review 10.  Closing the gap: accelerating the translational process in nanomedicine by proposing standardized characterization techniques.

Authors:  Ali A Khorasani; James L Weaver; Carolina Salvador-Morales
Journal:  Int J Nanomedicine       Date:  2014-12-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.