Accuracy of the method for estimating breast volume on three-dimensional simulated magnetic resonance imaging scans in breast reconstruction.

Eun Young Rha1, Ik Kyun Choi, Gyeol Yoo.   

Abstract

BACKGROUND: The authors have developed a simple and intuitive method for measuring breast volume based on three-dimensional simulated images of magnetic resonance imaging scans to accurately estimate breast volume before breast reconstruction.
METHODS: The authors performed a retrospective review of the medical records of 18 patients (20 breasts) who had undergone breast reconstruction at Yeouido St. Mary's Hospital from March of 2009 to July of 2012. All of the patients underwent preoperative assessment of breast volume with two methods: a plaster cast maneuver and a three-dimensional simulated magnetic resonance imaging scan. To determine the accuracy of each method, the authors compared the mastectomy volume with the plaster cast maneuver and with three-dimensional simulated magnetic resonance imaging.
RESULTS: In the authors' series, the mean values of the plaster cast maneuver, three-dimensional simulated magnetic resonance imaging, and mastectomy volume were 433.85 ± 176.65 ml, 529 ± 193.33 ml, and 495.25 ± 192.45 ml, respectively. In addition, the mean error between the plaster cast maneuver and mastectomy volume was 137.4 ± 97.66 ml and that between three-dimensional simulated magnetic resonance imaging and mastectomy volume was 54.63 ± 46.30 ml. From a linear regression curve, the correlation coefficient (r2) of the plaster cast maneuver was 0.629 (p = 0.003) and that of three-dimensional simulated magnetic resonance imaging was 0.945 (p < 0.001).
CONCLUSIONS: The authors' method for preoperatively measuring breast volume on three-dimensional simulated magnetic resonance imaging scans was both efficient and accurate. It would therefore be useful for achieving better aesthetic outcomes of breast reconstruction.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24374666     DOI: 10.1097/01.prs.0000436813.03838.09

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  6 in total

Review 1.  Alternative flaps in autologous breast reconstruction.

Authors:  Paige L Myers; Jonas A Nelson; Robert J Allen
Journal:  Gland Surg       Date:  2021-01

2.  Breast Volume Measurement by Recycling the Data Obtained From 2 Routine Modalities, Mammography and Magnetic Resonance Imaging.

Authors:  Shizu Itsukage; Yoshihiro Sowa; Mariko Goto; Tetsuya Taguchi; Toshiaki Numajiri
Journal:  Eplasty       Date:  2017-12-20

3.  Nonsubjective Assessment of Shape, Volume and Symmetry during Breast Augmentation with Handheld 3D Device.

Authors:  Zhouxiao Li; Thilo Ludwig Schenck; Riccardo Enzo Giunta; Lucas Etzel; Konstantin Christoph Koban
Journal:  J Clin Med       Date:  2022-07-11       Impact factor: 4.964

4.  Mammography with a fully automated breast volumetric software as a novel method for estimating the preoperative breast volume prior to mastectomy.

Authors:  Jin Sung Kim; Kyoungkyg Bae; Eun Ji Lee; Minseo Bang
Journal:  Ann Surg Treat Res       Date:  2021-06-01       Impact factor: 1.859

5.  Avoiding a Systematic Error in Assessing Fat Graft Survival in the Breast with Repeated Magnetic Resonance Imaging.

Authors:  Peter V Glovinski; Mikkel Herly; Felix C Müller; Jens J Elberg; Stig-Frederik T Kølle; Anne Fischer-Nielsen; Carsten Thomsen; Krzysztof T Drzewiecki
Journal:  Plast Reconstr Surg Glob Open       Date:  2016-09-08

6.  Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study.

Authors:  Woo Yeon Lee; Min Jung Kim; Dae Hyun Lew; Seung Yong Song; Dong Won Lee
Journal:  Arch Plast Surg       Date:  2016-09-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.