Literature DB >> 24372629

Analysis of HER2 status in breast carcinoma by fully automated HER2 fluorescence in situ hybridization (FISH): comparison of two immunohistochemical tests and manual FISH.

Nara Yoon1, In-Gu Do, Eun Yoon Cho.   

Abstract

Easy and accurate HER2 testing is essential when considering the prognostic and predictive significance of HER2 in breast cancer. The use of a fully automated, quantitative FISH assay would be helpful to detect HER2 amplification in breast cancer tissue specimens with reduced inter-laboratory variability. We compared the concordance of HER2 status as assessed by an automated FISH staining system to manual FISH testing. Using 60 formalin-fixed paraffin-embedded breast carcinoma specimens, we assessed HER2 immunoexpression with two antibodies (DAKO HercepTest and CB11). In addition, HER2 status was evaluated with automated FISH using the Leica FISH System for BOND and a manual FISH using the Abbott PathVysion DNA Probe Kit. All but one specimen were successfully stained using both FISH methods. When the data were divided into two groups according to HER2/CEP17 ratio, positive and negative, the results from both the automated and manual FISH techniques were identical for all 59 evaluable specimens. The HER2 and CEP17 copy numbers and HER2/CEP17 ratio showed great agreement between both FISH methods. The automated FISH technique was interpretable with signal intensity similar to those of the manual FISH technique. In contrast with manual FISH, the automated FISH technique showed well-preserved architecture due to low membrane digestion. HER2 immunohistochemistry and FISH results showed substantial significant agreement (κ = 1.0, p < 0.001). HER2 status can be reliably determined using a fully automated HER2 FISH system with high concordance to the well-established manual FISH method. Because of stable signal intensity and high staining quality, the automated FISH technique may be more appropriate than manual FISH for routine applications.
© 2013 APMIS. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Genes; automation; breast; carcinoma; ductal; erbB-2; fluorescence; in situ hybridization

Mesh:

Substances:

Year:  2013        PMID: 24372629     DOI: 10.1111/apm.12215

Source DB:  PubMed          Journal:  APMIS        ISSN: 0903-4641            Impact factor:   3.205


  3 in total

1.  Automated detection of the HER2 gene amplification status in Fluorescence in situ hybridization images for the diagnostics of cancer tissues.

Authors:  Falk Zakrzewski; Walter de Back; Martin Weigert; Torsten Wenke; Silke Zeugner; Robert Mantey; Christian Sperling; Katrin Friedrich; Ingo Roeder; Daniela Aust; Gustavo Baretton; Pia Hönscheid
Journal:  Sci Rep       Date:  2019-06-03       Impact factor: 4.379

2.  The effect of an alternative chromosome 17 probe on fluorescence in situ hybridization for the assessment of HER2 amplification in invasive breast cancer.

Authors:  Zhigao Xu; Peipei Xu; Wei Fan; Ben Huang; Qingyuan Cheng; Zheng Zhang; Ping Wang; Mingxia Yu
Journal:  Exp Ther Med       Date:  2019-07-09       Impact factor: 2.447

3.  Validation of break-apart and fusion MYC probes using a digital fluorescence in situ hybridization capture and imaging system.

Authors:  Michael Liew; Leslie Rowe; Parker W Clement; Rodney R Miles; Mohamed E Salama
Journal:  J Pathol Inform       Date:  2016-05-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.