Literature DB >> 24370268

Using Kinect™ sensor in observational methods for assessing postures at work.

Jose Antonio Diego-Mas1, Jorge Alcaide-Marzal2.   

Abstract

This paper examines the potential use of Kinect™ range sensor in observational methods for assessing postural loads. Range sensors can detect the position of the joints at high sampling rates without attaching sensors or markers directly to the subject under study. First, a computerized OWAS ergonomic assessment system was implemented to permit the data acquisition from Kinect™ and data processing in order to identify the risk level of each recorded postures. Output data were compared with the results provided by human observers, and were used to determine the influence of the sensor view angle relative to the worker. The tests show high inter-method agreement in the classification of risk categories (Proportion agreement index = 0.89 κ = 0.83) when the tracked subject is facing the sensor. The camera's point of view relative to the position of the tracked subject significantly affects the correct classification of the postures. Although the results are promising, some aspects involved in the use of low-cost range sensors should be further studied for their use in real environments.
Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

Entities:  

Keywords:  Ergonomics; Kinect; OWAS

Mesh:

Year:  2013        PMID: 24370268     DOI: 10.1016/j.apergo.2013.12.001

Source DB:  PubMed          Journal:  Appl Ergon        ISSN: 0003-6870            Impact factor:   3.661


  13 in total

1.  Evaluation of spinal posture using Microsoft Kinect™: A preliminary case-study with 98 volunteers.

Authors:  A P G Castro; J D Pacheco; C Lourenço; S Queirós; A H J Moreira; N F Rodrigues; J L Vilaça
Journal:  Porto Biomed J       Date:  2016-12-27

2.  Validity of sagittal thoracolumbar curvature measurement using a non-radiographic surface topography method.

Authors:  Erin Hannink; Helen Dawes; Thomas M L Shannon; Karen L Barker
Journal:  Spine Deform       Date:  2022-07-09

3.  Classification of body postures using smart workwear.

Authors:  Christian Lins; Andreas Hein
Journal:  BMC Musculoskelet Disord       Date:  2022-10-18       Impact factor: 2.562

4.  Pose estimation with a Kinect for ergonomic studies: evaluation of the accuracy using a virtual mannequin.

Authors:  Pierre Plantard; Edouard Auvinet; Anne-Sophie Le Pierres; Franck Multon
Journal:  Sensors (Basel)       Date:  2015-01-15       Impact factor: 3.576

Review 5.  Musculoskeletal disorders: OWAS review.

Authors:  Marta Gómez-Galán; José Pérez-Alonso; Ángel-Jesús Callejón-Ferre; Javier López-Martínez
Journal:  Ind Health       Date:  2017-05-09       Impact factor: 2.179

6.  Bilateral Tactile Feedback-Enabled Training for Stroke Survivors Using Microsoft KinectTM.

Authors:  Abbas Orand; Eren Erdal Aksoy; Hiroyuki Miyasaka; Carolyn Weeks Levy; Xin Zhang; Carlo Menon
Journal:  Sensors (Basel)       Date:  2019-08-08       Impact factor: 3.576

7.  Combining Ergonomic Risk Assessment (RULA) with Inertial Motion Capture Technology in Dentistry-Using the Benefits from Two Worlds.

Authors:  Christian Maurer-Grubinger; Fabian Holzgreve; Laura Fraeulin; Werner Betz; Christina Erbe; Doerthe Brueggmann; Eileen M Wanke; Albert Nienhaus; David A Groneberg; Daniela Ohlendorf
Journal:  Sensors (Basel)       Date:  2021-06-13       Impact factor: 3.576

8.  Wearable Devices for Classification of Inadequate Posture at Work Using Neural Networks.

Authors:  Eya Barkallah; Johan Freulard; Martin J-D Otis; Suzy Ngomo; Johannes C Ayena; Christian Desrosiers
Journal:  Sensors (Basel)       Date:  2017-09-01       Impact factor: 3.576

9.  Filtered pose graph for efficient kinect pose reconstruction.

Authors:  Pierre Plantard; Hubert P H Shum; Franck Multon
Journal:  Multimed Tools Appl       Date:  2016-05-13       Impact factor: 2.757

10.  A Wearable Sensor System for Physical Ergonomics Interventions Using Haptic Feedback.

Authors:  Carl Mikael Lind; Jose Antonio Diaz-Olivares; Kaj Lindecrantz; Jörgen Eklund
Journal:  Sensors (Basel)       Date:  2020-10-23       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.