Literature DB >> 24369000

Percutaneous cannulated screws with tension band wiring technique in patella fractures.

Jin-Ho Cho1.   

Abstract

INTRODUCTION: Most patellar fractures are transverse involving the central third. Open reduction and stabilization of transverse patellar fractures is indicated if there is more than 2-3 mm of fragment separation and/or articular incongruity. SURGICAL TECHNIQUE: This study describes a percutaneous 2 cannulated screws and modified tension band wiring technique to treat transverse patellar fractures.
MATERIALS AND METHODS: We performed 30 cases of displaced transverse patellar fractures with this technique. The clinical outcomes of these patients were evaluated with simple radiographs, range of motion and Lyshom score.
RESULTS: This technique has shown to provide satisfactory clinical results and excellent knee functions.
CONCLUSIONS: This technique provide stable fixation, allows early motion exercise by minimizing injury to extensor mechanism and reduce cosmetic problem in scar.

Entities:  

Keywords:  Cannulated screw; Fracture; Modified tension band technique; Patella; Percutaneous surgery

Year:  2013        PMID: 24369000      PMCID: PMC3867615          DOI: 10.5792/ksrr.2013.25.4.215

Source DB:  PubMed          Journal:  Knee Surg Relat Res        ISSN: 2234-0726


  15 in total

1.  Arthroscopically assisted percutaneous osteosynthesis of displaced transverse patellar fractures with figure-eight wiring through paired cannulated screws.

Authors:  Chao-Ching Chiang; Ching-Kuei Huang; Wei-Ming Chen; Chien-Fu Jeff Lin; Yun-Hsuan Tzeng; Chien-Lin Liu
Journal:  Arch Orthop Trauma Surg       Date:  2010-12-25       Impact factor: 3.067

2.  Biomechanical evaluation of current patella fracture fixation techniques.

Authors:  J E Carpenter; R A Kasman; N Patel; M L Lee; S A Goldstein
Journal:  J Orthop Trauma       Date:  1997-07       Impact factor: 2.512

3.  Open fractures of the patella: long-term functional outcome.

Authors:  J B Catalano; W M Iannacone; S Marczyk; R M Dalsey; L S Deutsch; C T Born; W G Delong
Journal:  J Trauma       Date:  1995-09

4.  Percutaneous tension band wiring: a new method of internal fixation for mildly displaced patella fracture.

Authors:  P C Leung; K H Mak; S Y Lee
Journal:  J Trauma       Date:  1983-01

5.  Comparison of a technique using a new percutaneous osteosynthesis device with conventional open surgery for displaced patella fractures in a randomized controlled trial.

Authors:  Daniel Luna-Pizarro; Dante Amato; Francisco Arellano; Armando Hernández; Pablo López-Rojas
Journal:  J Orthop Trauma       Date:  2006-09       Impact factor: 2.512

6.  Clinical experience of patellar fracture fixation using metal wire or non-absorbable polyester--a study of 37 cases.

Authors:  H S Gosal; P Singh; R E Field
Journal:  Injury       Date:  2001-03       Impact factor: 2.586

Review 7.  Fractures of the patella.

Authors:  J E Carpenter; R Kasman; L S Matthews
Journal:  Instr Course Lect       Date:  1994

8.  Fracture of the patella. A study of 422 patellar fractures.

Authors:  A Boström
Journal:  Acta Orthop Scand Suppl       Date:  1972

9.  Fractured patella: operative treatment using the tension band principle.

Authors:  L K Hung; K M Chan; Y N Chow; P C Leung
Journal:  Injury       Date:  1985-03       Impact factor: 2.586

10.  Cannulated screw and cable are superior to modified tension band in the treatment of transverse patella fractures.

Authors:  Yun Tian; Fang Zhou; Hongquan Ji; Zhishan Zhang; Yan Guo
Journal:  Clin Orthop Relat Res       Date:  2011-05-15       Impact factor: 4.176

View more
  9 in total

1.  Comparison of Functional and Radiological Outcomes of Transverse Patellar Fractures Fixed with Tension Band Fixation Using Cannulated Screws and Kirschner Wires: A Prospective Randomized Study.

Authors:  Nikhil Drolia; Siddhartha Sinha; Shiva Raj Paneru; Arvind Kumar; Javed Jameel; Sandeep Kumar; Bikram Shrestha; Guru P Khanal
Journal:  Indian J Orthop       Date:  2021-08-30       Impact factor: 1.033

Review 2.  Comparison of minimally invasive percutaneous fixation and open reduction internal fixation for patella fractures: a meta-analysis.

Authors:  Chun-Hong Lo; Chih-Hwa Chen
Journal:  J Orthop Surg Res       Date:  2021-08-17       Impact factor: 2.359

3.  Lower Extremity Salvage in a Diabetic Patient With Cutaneous Mucormycosis and COVID-19 After Open Patella Fracture.

Authors:  Danny A S Hammoudi; Malika M Morar; Anna Garbuzov; Daniel Urias; Kristopher M Katira
Journal:  Ochsner J       Date:  2022

4.  Comparison of a minimally invasive surgical technique with open surgery for transverse patella fractures.

Authors:  Jie Shao; Jiabao Wang; Yu Chen; Ningfang Mao; Qiulin Zhang; Haijian Ni
Journal:  Exp Ther Med       Date:  2019-10-04       Impact factor: 2.447

Review 5.  Treatment for transverse patella fractures with minimally invasive techniques (Review).

Authors:  Xiang-Yu Ma; Bing Liu; Da-Peng Zhou; Liang-Bi Xiang
Journal:  Exp Ther Med       Date:  2022-01-05       Impact factor: 2.447

Review 6.  Current concepts review: Fractures of the patella.

Authors:  Clemens Gwinner; Sven Märdian; Philipp Schwabe; Klaus-D Schaser; Björn Dirk Krapohl; Tobias M Jung
Journal:  GMS Interdiscip Plast Reconstr Surg DGPW       Date:  2016-01-18

7.  Internal Fixation of Transverse Patella Fractures Using Cannulated Cancellous Screws with Anterior Tension Band Wiring.

Authors:  I Khan; M Y Dar; S Rashid; M F Butt
Journal:  Malays Orthop J       Date:  2016-07

8.  A comparison of EFECE systems with tension band wiring for patella fracture fixation in cadavers.

Authors:  Emre Karadeniz; Elif Nedret Keskinoz
Journal:  J Orthop Surg Res       Date:  2020-07-10       Impact factor: 2.359

9.  [Current treatment standard for patella fractures in Germany].

Authors:  Kai Fehske; Markus T Berninger; Lena Alm; Reinhard Hoffmann; Johannes Zellner; Clemens Kösters; Stefan Barzen; Michael J Raschke; Kaywan Izadpanah; Elmar Herbst; Christoph Domnick; Jan Philipp Schüttrumpf; Matthias Krause
Journal:  Unfallchirurg       Date:  2020-12-17       Impact factor: 1.000

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.