Mahmoud Fathy Hassan1, Nancy Mohamed Ali Rund2, Ahmed Husseiny Salama2.
Abstract
Background. To assess the ability of mid-trimester sFlt-1/PlGF ratio for prediction of preeclampsia in two different Arabic populations. Methods. This study measured levels of sFlt-1, PlGF, and sFlt-1/PlGF ratio at midtrimester in 83 patients who developed preeclampsia with contemporary 250 matched controls. Results. Women subsequently developed preeclampsia had significantly lower PlGF levels and higher sFlt-1 and sFlt-1/PlGF ratio levels than women with normal pregnancies (P < 0.0001 for all). Women who with preterm preeclampsia had significantly higher sFlt-1 and sFlt-1/PlGF ratio than term preeclamptic women (P = 0.01, 0.003, resp.). A cutoff value of 3198 pg/mL for sFlt-1 was able to predict preeclampsia with sensitivity, specificity, and accuracy of 88%, 83.6%, and 84.7%, respectively, with odds ratio (OR) 37.2 [95% confidence interval (CI) 17.7-78.1]. PIGF at cutoff value of 138 pg/mL was able to predict preeclampsia with sensitivity, specificity, and accuracy of 85.5%, 77.2%, and 79.3%, respectively, with OR 20 [95% CI, 10.2-39.5]. The sFlt-1/PIGF ratio at cutoff value of 24.5 was able to predict preeclampsia with sensitivity, specificity, and accuracy of 91.6%, 86.4%, and 87.7%, respectively with OR 67 [95% CI, 29.3-162.1]. Conclusion. Midtrimester sFlt-1/PlGF ratio displayed the highest sensitivity, specificity, accuracy, and OR for prediction of preeclampsia, demonstrating that it may stipulate more effective prediction of preeclampsia development than individual factor assay.Entities:
Year: 2013 PMID: 24367379 PMCID: PMC3866774 DOI: 10.1155/2013/202346
Source DB: PubMed Journal: Obstet Gynecol Int ISSN: 1687-9597
Demographic and clinical characteristics of women with normotensive pregnancies and women who eventually developed preeclampsia.
| Variable | Preeclampsia patients ( | Matched controls ( |
|
|---|---|---|---|
| Characteristics at sampling | |||
| Age (year) | 26 (9) | 26.5 (11) | 0.466 |
| Body mass index (kg/m2) | 24.7 ± 3.1 | 23.9 ± 4.6 | 0.141 |
| Nulliparous, | 66 (79.5) | 176 (70.4) | 0.119 |
| Gestational age (week) | 16.9 ± 1.9 | 16.4 ± 2.8 | 0.131 |
| Systolic blood pressure (mm Hg) | 115.2 ± 14.9 | 117.1 ± 16.3 | 0.348 |
| Diastolic blood pressure (mm Hg) | 68.6 ± 9.4 | 70.6 ± 11.6 | 0.156 |
| Urine protein (dipstick) | Negative* | Negative* | |
| Characteristics at delivery | |||
| Gestational age at delivery (week) | 36.5 ± 1.8 | 39.2 ± 1.3 | <0.0001 |
| Birth weight (g) | 2510 (650) | 3000 (380) | <0.0001 |
*Negative, by dipstick analysis.
Data are presented as mean ± standard deviation, median (interquartile range), or number (%).
P value < 0.05 is significant.
Maternal plasma concentrations of sFlt-1, PlGF, and sFlt-1/PlGF ratio in women who developed preeclampsia and in controls.
| Variable | Preeclampsia patients ( | Matched controls ( |
|
|---|---|---|---|
| sFlt-1 (pg/mL) | 4490 (1080) | 2590 (419) | <0.0001 |
| PlGF (pg/mL) | 98 (35) | 186 (52) | <0.0001 |
| sFlt-1/PlGF ratio | 44.6 (16.2) | 14.4 (6.1) | <0.0001 |
sFlt-1: soluble fms-like tyrosine kinase 1; PlGF: placental growth factor.
Data are presented as median (interquartile range).
P value < 0.05 is significant.
Figure 1Median and interquartile range of fms-like tyrosine kinase (sFlt-1) in case group, 4490 (961) and in control group, 2591 (400); P < 0.0001.
Figure 2Median and interquartile range of placental growth factor in case group, 97 (29) and in control group, 186 (57.5); P < 0.0001.
Figure 3Median and interquartile range of sFlt-1/PlGF ratio in case group, 44.8 (16.2) and in control group, 14.4 (6.4); P < 0.0001.
Comparison of sFlt-1, PlGF, and sFlt-1/PlGF ratio in term and preterm preeclampsia.
| Variable | Term preeclampsia ( | Preterm preeclampsia ( |
|
|---|---|---|---|
| sFlt-1 (pg/mL) |
3960 (1268) | 4910 (885) | 0.01 |
| PlGF (pg/mL) |
101 (51) | 95 (24) | 0.12 |
| sFlt-1/PlGF ratio |
35.9 (14.2) | 49.5 (12.8) | 0.003 |
sFlt-1: soluble fms-like tyrosine kinase 1; PlGF: placental growth factor.
Data are presented as median (interquartile range).
P value < 0.05 is significant.
Area under the curve from the receiver operating characteristic curve analysis of sFlt-1, PlGF, and sFlt-1/PlGF ratio.
| Variable | AUC | 95% confidence interval | Sensitivity (%) at FPR | ||
|---|---|---|---|---|---|
| 5% | 10% | 15% | |||
| sFlt-1 | 0.875 |
0.823–0.926 | 44.6 | 73.5 | 83.6 |
| PlGF | 0.855 |
0.81–0.90 | 14.7 | 64 | 74.7 |
| sFlt-1/PlGF ratio | 0.917 |
0.88–0.954 | 59 | 81.9 | 91.6 |
AUC: area under the curve; FPR: false positive rate; sFlt-1: soluble fms-like tyrosine kinase 1; PlGF: placental growth factor.
False positive rate was calculated as 100 − specificity.
Figure 4Receiver operating characteristic (ROC) curve of fms-like tyrosine kinase (sFlt-1) in the prediction of preeclampsia. Area under the curve (AUC) = 0.891 (95% CI: 0.835–0.947; P < 0.0001).
Figure 5Receiver operating characteristic (ROC) curve of placental growth factor (PlGF) in the prediction of preeclampsia. Area under the curve (AUC) = 0.863 (95% CI: 0.818 to 0.907; P < 0.0001).
Figure 6Receiver operating characteristic (ROC) curve of sFlt-1/PlGF ratio in the prediction of preeclampsia. Area under the curve (AUC) = 0.916 (95% CI: 0.877 to 0.955; P < 0.0001).
Optimum cutoff values and odds ratio for preeclampsia according to cutoff values.
| Variable | Optimum cutoff value | Odds Ratio | 95% Confidence Interval |
|---|---|---|---|
| sFlt-1 (pg/mL) | 3198 | 37.2 | 17.7–78.1 |
| PlGF (pg/mL) | 138 | 20 | 10.2–39.5 |
| sFlt-1/PlGF ratio | 24.5 | 67 | 29.3–162.1 |
sFlt-1: soluble fms-like tyrosine kinase 1; PlGF: placental growth factor.
Sensitivity, specificity, PPV, NPV, PLH ratio, NLH ratio, and accuracy of sFlt-1, PlGF, and sFlt-1/PlGF ratio at the optimum cutoff value for prediction of preeclampsia.
| Variables | sFlt-1 | PlGF | sFlt-1/PlGF ratio |
|---|---|---|---|
| Sensitivity | 88 | 85.5 | 91.6 |
| Specificity | 83.6 | 77.2 | 86.4 |
| PPV | 64 | 55.5 | 69.1 |
| NPV | 95.4 | 94.1 | 96.9 |
| PLH ratio | 5.4 | 3.8 | 6.7 |
| NLH ratio | 0.14 | 0.19 | 0.1 |
| Accuracy (%) | 84.7 | 79.3 | 87.7 |
sFlt-1: soluble fms-like tyrosine kinase 1; PlGF: placental growth factor; CI: confidence interval; PPV: positive predictive value; NPV: negative predictive value; PLH: positive likelihood ratio; NLH: negative likelihood ratio.