Literature DB >> 24366794

Plating, nailing, external fixation, and fibular strut grafting for non-union of humeral shaft fractures.

Kedar P Padhye1, Vidhisha S Kulkarni, G S Kulkarni, Milind G Kulkarni, Sunil Kulkarni, Ruta Kulkarni, Mayur D Patil, Priyanka Y Ravi.   

Abstract

PURPOSE: To compare various treatment modalities (plating, Ilizarov external fixation, and non-vascular fibular cortical strut grafting) for non-union of humeral shaft fractures.
METHODS: Records of 9 women and 26 men aged 24 to 71 (mean, 42) years who presented with non-union of humeral shaft fractures were reviewed. The humeral shaft fractures were secondary to low-energy trauma (n=22) or vehicular accidents (n=13) and involved the proximal (n=9), middle (n=15), and distal (n=11) regions. 13 of the fractures were open. Infection was evident in 8 of the non-unions. For non-unions with infection (n=8), a 2-stage procedure entailing temporary Ilizarov fixation followed by plating was used. For non-unions without infection (n=23), one-stage plating and cancellous bone grafting was used. For non-unions of osteoporotic bone (n=4), one-stage non-vascularised fibular strut grafting was used. Outcome was measured using the Disabilities of the Arm, Shoulder and Hand (DASH) scoring system.
RESULTS: The 35 patients were followed up for a mean of 16 (range, 6-60) months. All achieved bone union except for one (who had persistent infection). Respectively for non-unions with infection, nonunions without infection, and non-unions of osteoporotic bone, the mean times to bone union were 6.5 (range, 4-10), 5 (range, 4-8), and 10 (range, 6-14) months, the mean improvement in DASH score was 30, 43, and 18, and malalignment was noted in 5, 2, and one patient. Three patients had a preoperative radial nerve palsy for which standard tendon transfer was performed 6 weeks after treatment for non-union.
CONCLUSION: Compression plating achieved the best results. An external fixator may be used temporarily for infected non-unions. Fibular strut grafting may be used when non-unions warrant additional stability.

Entities:  

Keywords:  Ilizarov technique; bone transplantation; external fixators; fibula; fractures, ununited; humeral fractures

Mesh:

Year:  2013        PMID: 24366794     DOI: 10.1177/230949901302100313

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  9 in total

1.  Autologous Nonvascularized Fibula Graft and Locking Compression Plating for Failed Fixation of Humeral Shaft With Atrophic Gap Nonunion.

Authors:  Karan Shetty; Naga Cheppalli; Deepak Kaki
Journal:  Cureus       Date:  2022-04-19

2.  Why a surgically treated humeral shaft fracture became a nonunion: review of 11 years in two trauma centers.

Authors:  A Maresca; P Sangiovanni; S Cerbasi; R Politano; R Fantasia; M Commessatti; R Pascarella
Journal:  Musculoskelet Surg       Date:  2017-10-19

3.  Role of autologous non-vascularised intramedullary fibular strut graft in humeral shaft nonunions following failed plating.

Authors:  Sreekanth Kashayi-Chowdojirao; Aashish Vallurupalli; Vijay Krishna Chilakamarri; Chandrasekhar Patnala; Lalith Mohan Chodavarapu; Nageswara Rao Kancherla; Asif Hussain Khazi Syed
Journal:  J Clin Orthop Trauma       Date:  2016-12-22

4.  Dual plating for fixation of humeral shaft fractures: A mechanical comparison of various combinations of plate lengths.

Authors:  Ahmet Karakasli; Onur Basci; Fatih Ertem; Eyad Sekik; Hasan Havitcioglu
Journal:  Acta Orthop Traumatol Turc       Date:  2016-07-29       Impact factor: 1.511

5.  Lateral Subcutaneous Locking Compression Plate and Small Incision Reduction for Distal-third Diaphyseal Humerus Fractures.

Authors:  Hong Chang; Zi-Long Yao; Yi-Long Hou; Yang Cao; Xin-Hui Guo; Guan-Jun Li; Bin Yu
Journal:  Orthop Surg       Date:  2018-08       Impact factor: 2.071

6.  Humeral Diaphyseal Fracture Nonunion: An Audit of the Outcome from Intramedullary Nailing and DCP Plating.

Authors:  Ivan Micic; Erica Kholinne; Jae-Man Kwak; Yucheng Sun; Akriti Nanda; Hyojune Kim; Kyoung-Hwan Koh; In-Ho Jeon
Journal:  Biomed Res Int       Date:  2019-07-22       Impact factor: 3.411

7.  Treatment of nonunions of the humeral shaft with nonvascularized fibular strut allograft: postoperative outcomes and review of a surgical technique.

Authors:  Leslie A Fink Barnes; Daniel F H Ruig; Christina E Freibott; Rebecca Rajfer; Melvin P Rosenwasser
Journal:  JSES Int       Date:  2020-10-09

Review 8.  Nine-year-long complex humeral nonunion salvaged by distraction osteogenesis technique: a case report and review of the literature.

Authors:  Qiyu Jia; Yanshi Liu; Abudusalamu Alimujiang; Jian Guo; Dongsheng Chen; Yingbo Wang; Aihemaitijiang Yusufu; Chuang Ma
Journal:  BMC Surg       Date:  2022-03-03       Impact factor: 2.102

9.  COMPARISON OF SINGLE- AND DOUBLE-PLATE FIXATION TECHNIQUES IN THE TREATMENT OF NONUNIONS OF THE HUMERAL SHAFT.

Authors:  Mehmet Akdemir; Çağdaş Biçen; Mustafa Özkan
Journal:  Acta Ortop Bras       Date:  2022-01-28       Impact factor: 0.513

  9 in total