Literature DB >> 24365048

Evoked hemodynamic response estimation using ensemble empirical mode decomposition based adaptive algorithm applied to dual channel functional near infrared spectroscopy (fNIRS).

Nima Hemmati Berivanlou1, Seyed Kamaledin Setarehdan2, Hossein Ahmadi Noubari3.   

Abstract

BACKGROUND: The quality of the functional near infrared spectroscopy (fNIRS) recordings is highly degraded by the presence of physiological interferences. It is crucial to efficiently separate the evoked hemodynamic responses (EHRs) from other background hemodynamic activities prior to any further processing. NEW
METHOD: This paper presents a novel algorithm for physiological interferences reduction from the dual channel fNIRS measurements using ensemble empirical mode decomposition (EEMD) technique. The proposed algorithm is comprised of two main steps: (1) decomposing reference signal into its constituents called intrinsic mode functions (IMFs) and (2) adaptively defining appropriate weights of the corresponding IMFs to estimate the proportion of physiological interference in standard channel measurement.
RESULTS: Performance of the proposed algorithm was evaluated using both synthetic and semi-real brain hemodynamic data based on four parameters of relative mean squared error (rMSE), Pearson's correlation coefficient (R(2)), percentage estimation error of peak amplitude (EPA) and peak latency (EL). COMPARISON WITH EXISTING
METHODS: Results obtained from synthetic data revealed that both the EEMD based normalized least mean squares (EEMD-NLMS) and EEMD based recursive least squares (EEMD-RLS) methods could reduce the average rMSE by at least 34% and 49%, respectively, when compared with widely used methods: block averaging, band-pass filtering and principal and/or independent component analysis. Furthermore, the two proposed methods outperform the regression method in reducing rMSE by at least 21% and 35% respectively when applied to semi-real data.
CONCLUSIONS: An effective algorithm for estimating the EHRs from raw fNIRS data was proposed in which no assumption about the amplitude, shape and duration of the responses is considered.
Copyright © 2013 Elsevier B.V. All rights reserved.

Keywords:  Adaptive filters; Ensemble empirical mode decomposition (EEMD); Evoked hemodynamic response (EHR); Functional near infrared spectroscopy (fNIRS); Systemic interference

Mesh:

Substances:

Year:  2013        PMID: 24365048     DOI: 10.1016/j.jneumeth.2013.12.007

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  3 in total

1.  Artifact reduction in long-term monitoring of cerebral hemodynamics using near-infrared spectroscopy.

Authors:  Sarah A Vinette; Jeff F Dunn; Edward Slone; Paolo Federico
Journal:  Neurophotonics       Date:  2015-05-26       Impact factor: 3.593

2.  Evoked Hemodynamic Response Estimation to Auditory Stimulus Using Recursive Least Squares Adaptive Filtering with Multidistance Measurement of Near-Infrared Spectroscopy.

Authors:  Yan Zhang; Xin Liu; Dan Liu; Chunling Yang; Qisong Wang; Jinwei Sun; Kuanquan Wang
Journal:  J Healthc Eng       Date:  2018-03-29       Impact factor: 2.682

Review 3.  Neuroprotection of the Perinatal Brain by Early Information of Cerebral Oxygenation and Perfusion Patterns.

Authors:  Filipe Gonçalves Costa; Naser Hakimi; Frank Van Bel
Journal:  Int J Mol Sci       Date:  2021-05-20       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.