Literature DB >> 24361599

Ultrasound elastography using multiple images.

Hassan Rivaz1, Emad M Boctor2, Michael A Choti3, Gregory D Hager4.   

Abstract

Displacement estimation is an essential step for ultrasound elastography and numerous techniques have been proposed to improve its quality using two frames of ultrasound RF data. This paper introduces a technique for calculating a displacement field from three (or multiple) frames of ultrasound RF data. To calculate a displacement field using three images, we first derive constraints on variations of the displacement field with time using mechanics of materials. These constraints are then used to generate a regularized cost function that incorporates amplitude similarity of three ultrasound images and displacement continuity. We optimize the cost function in an expectation maximization (EM) framework. Iteratively reweighted least squares (IRLS) is used to minimize the effect of outliers. An alternative approach for utilizing multiple images is to only consider two frames at any time and sequentially calculate the strains, which are then accumulated. We formally show that, compared to using two images or accumulating strains, the new algorithm reduces the noise and eliminates ambiguities in displacement estimation. The displacement field is used to generate strain images for quasi-static elastography. Simulation, phantom experiments and in vivo patient trials of imaging liver tumors and monitoring ablation therapy of liver cancer are presented for validation. We show that even with the challenging patient data, where it is likely to have one frame among the three that is not optimal for strain estimation, the introduction of physics-based prior as well as the simultaneous consideration of three images significantly improves the quality of strain images. Average values for strain images of two frames versus ElastMI are: 43 versus 73 for SNR (signal to noise ratio) in simulation data, 11 versus 15 for CNR (contrast to noise ratio) in phantom data, and 5.7 versus 7.3 for CNR in patient data. In addition, the improvement of ElastMI over both utilizing two images and accumulating strains is statistically significant in the patient data, with p-values of respectively 0.006 and 0.012.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Elasticity imaging; Expectation Maximization (EM); Liver ablation; Strain imaging; Ultrasound elastography

Mesh:

Year:  2013        PMID: 24361599     DOI: 10.1016/j.media.2013.11.002

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  7 in total

1.  Deformable registration of preoperative MR, pre-resection ultrasound, and post-resection ultrasound images of neurosurgery.

Authors:  Hassan Rivaz; D Louis Collins
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-11-06       Impact factor: 2.924

2.  An adaptive displacement estimation algorithm for improved reconstruction of thermal strain.

Authors:  Xuan Ding; Debaditya Dutta; Ahmed M Mahmoud; Bryan Tillman; Steven A Leers; Kang Kim
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-01       Impact factor: 2.725

3.  A coupled subsample displacement estimation method for ultrasound-based strain elastography.

Authors:  Jingfeng Jiang; Timothy J Hall
Journal:  Phys Med Biol       Date:  2015-10-12       Impact factor: 3.609

4.  Plane-Wave Imaging Improves Single-Track Location Shear Wave Elasticity Imaging.

Authors:  Rifat Ahmed; Scott A Gerber; Stephen A McAleavey; Giovanni Schifitto; Marvin M Doyley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-06-01       Impact factor: 2.725

5.  The role of elastography in the assessment of chronic liver disease in children.

Authors:  Süleyman Sönmez; Merve Boşat; Nihal Yurtseven; Eray Yurtseven
Journal:  Afr Health Sci       Date:  2019-09       Impact factor: 0.927

6.  Spatiotemporal Bayesian Regularization for Cardiac Strain Imaging: Simulation and In Vivo Results.

Authors:  Rashid Al Mukaddim; Nirvedh H Meshram; Ashley M Weichmann; Carol C Mitchell; Tomy Varghese
Journal:  IEEE Open J Ultrason Ferroelectr Freq Control       Date:  2021-11-22

7.  Nonlocal Coherent Denoising of RF Data for Ultrasound Elastography.

Authors:  P Khavari; A Asif; M Boily; H Rivaz
Journal:  J Healthc Eng       Date:  2018-06-24       Impact factor: 2.682

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.