Literature DB >> 24361353

Optimization of reaction conditions for the radiolabeling of DOTA and DOTA-peptide with (44m/44)Sc and experimental evidence of the feasibility of an in vivo PET generator.

S Huclier-Markai1, R Kerdjoudj2, C Alliot3, A C Bonraisin4, N Michel4, F Haddad5, J Barbet3.   

Abstract

INTRODUCTION: Among the number of generator systems providing radionuclides with decay parameters promising for imaging and treatment applications, there is the (44)Ti (T1/2=60 years)/(44)Sc (T1/2=3.97 h) generator. This generator provides a longer-lived daughter for extended PET/CT measurements compared to the chemically similar system (68)Ge/(68)Ga. Scandium also exists as (47)Sc, a potential therapeutic radionuclide. It is possible to produce (44)Sc in a cyclotron using, for example, the (44)Ca (d, n) (44)Sc nuclear reaction. In that case, the isomeric state (44 m)Sc (T1/2=58.6h) is co-produced and may be used as an in vivo(44 m)Sc/(44)Sc generator. The aim of this study is to evaluate the feasibility of this in vivo(44 m)Sc/(44)Sc generator and to demonstrate that the daughter radionuclide stays inside the chelator after decay of the parent radionuclide. Indeed, the physico-chemical process occurring after the primary radioactive decay (EC, IT, Auger electron …) has prevented in many cases the use of in-vivo generator, because of the post-effect as described in the literature.
METHODS: The DOTA macrocyclic ligand forms stable complexes with many cations and has been shown to be the most suitable chelating moiety for scandium. Initially, the radiolabeling of DOTA and a DOTA-peptide (DOTATATE) with Sc was performed and optimized as a function of time, pH, metal-to-ligand ratio and temperature. Next, the physico-chemical processes that could occur after the decay (post-effect) were studied. (44 m)Sc(III)-labeled DOTA-peptide was quantitatively adsorbed on a solid phase matrix through a hydrophobic interaction. Elutions were then performed at regular time intervals using a DTPA solution at various concentrations. Finally, the radiolabelled complex stability was studied in serum.
RESULTS: Radiolabeling yields ranged from 90% to 99% for metal-to-ligand ratio ranging from 1:10 to 1:500 for DOTA or DOTATATE respectively. The optimum physico-chemical parameters were pH=4-6, t=20 min, T=70°C. Then, the (44 m)Sc-DOTATATE complex, radiolabeled at 98%, was adsorbed through a hydrophobic interaction to a solid phase. Unlabeled scandium was completely eluted from the column whereas the Sc-DOTATATE complex was 100% retained. The release of (44)Sc from the complex due to decay was less than 1% over 2 periods of (44 m)Sc, independent of the DTPA concentration used for elution. (44 m)Sc/(44)Sc-DOTATATE was stable in serum over 72 h.
CONCLUSIONS: The results indicate that the decay of (44 m)Sc to (44)Sc does not affect the integrity of the radiolabeled compound. Thus the (44 m)Sc/(44)Sc generator is chemically valid and stable in serum. It could be used for PET imaging as an in-vivo generator increasing the life time of the scandium and allowing the use of antibody as labelled compound. Further in-vivo biological evaluations should complete this work.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  (44)Sc; (44m)Sc; DOTATATE; In vivo generator; PET

Mesh:

Substances:

Year:  2013        PMID: 24361353     DOI: 10.1016/j.nucmedbio.2013.11.004

Source DB:  PubMed          Journal:  Nucl Med Biol        ISSN: 0969-8051            Impact factor:   2.408


  5 in total

Review 1.  Is there an interest to use deuteron beams to produce non-conventional radionuclides?

Authors:  Cyrille Alliot; Nadia Audouin; Jacques Barbet; Anne-Cecile Bonraisin; Valérie Bossé; Cécile Bourdeau; Mickael Bourgeois; Charlotte Duchemin; Arnaud Guertin; Ferid Haddad; Sandrine Huclier-Markai; Rabah Kerdjoudj; Johan Laizé; Vincent Métivier; Nathalie Michel; Marcel Mokili; Mickael Pageau; Aurélien Vidal
Journal:  Front Med (Lausanne)       Date:  2015-05-11

Review 2.  In Vivo Radionuclide Generators for Diagnostics and Therapy.

Authors:  Patricia E Edem; Jesper Fonslet; Andreas Kjær; Matthias Herth; Gregory Severin
Journal:  Bioinorg Chem Appl       Date:  2016-12-12       Impact factor: 7.778

Review 3.  Production of novel diagnostic radionuclides in small medical cyclotrons.

Authors:  Mateusz Adam Synowiecki; Lars Rutger Perk; J Frank W Nijsen
Journal:  EJNMMI Radiopharm Chem       Date:  2018-02-20

4.  47Sc production development by cyclotron irradiation of 48Ca.

Authors:  R Misiak; R Walczak; B Wąs; M Bartyzel; J W Mietelski; A Bilewicz
Journal:  J Radioanal Nucl Chem       Date:  2017-06-13       Impact factor: 1.371

5.  Cyclotron production of (43)Sc for PET imaging.

Authors:  Rafał Walczak; Seweryn Krajewski; Katarzyna Szkliniarz; Mateusz Sitarz; Kamel Abbas; Jarosław Choiński; Andrzej Jakubowski; Jerzy Jastrzębski; Agnieszka Majkowska; Federica Simonelli; Anna Stolarz; Agnieszka Trzcińska; Wiktor Zipper; Aleksander Bilewicz
Journal:  EJNMMI Phys       Date:  2015-12-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.