Literature DB >> 24360759

Comparison of microgyro-based measurements of equine metatarsal/metacarpal bone to a high speed video locomotion analysis system during treadmill locomotion.

L Roepstorff1, T Wiestner2, M A Weishaupt2, E Egenvall3.   

Abstract

The aim of this study was to compare an inertial motion system (IMS) to an optical based locomotion analysis system measuring limb sagittal segment angles in horses at the walk and trot. The metatarsal/metacarpal bones of two horses (20 trials) were fitted with optical system markers and an IMS. Between the systems, measuring range of motion (ROM) of the sagittal metatarsal/metacarpal bone angles, the IMS measured higher ROM than the optical system (bias 1.6°; precision at 1.96 standard deviation 1.9°). The same angle data were used to assess inter-limb symmetry by calculating phase shift between the limbs within a stride. This showed essentially no bias and the precision was 0.025%. The IMS has potential for quantification of ROM and phase shift of equine distal limb movement.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Horses; Inertial motion sensor

Mesh:

Year:  2013        PMID: 24360759     DOI: 10.1016/j.tvjl.2013.09.052

Source DB:  PubMed          Journal:  Vet J        ISSN: 1090-0233            Impact factor:   2.688


  4 in total

1.  A Wearable Magnet-Based System to Assess Activity and Joint Flexion in Humans and Large Animals.

Authors:  Feini Qu; Brendan D Stoeckl; Peter M Gebhard; Todd J Hullfish; Josh R Baxter; Robert L Mauck
Journal:  Ann Biomed Eng       Date:  2018-08-06       Impact factor: 3.934

2.  EquiMoves: A Wireless Networked Inertial Measurement System for Objective Examination of Horse Gait.

Authors:  Stephan Bosch; Filipe Serra Bragança; Mihai Marin-Perianu; Raluca Marin-Perianu; Berend Jan van der Zwaag; John Voskamp; Willem Back; René van Weeren; Paul Havinga
Journal:  Sensors (Basel)       Date:  2018-03-13       Impact factor: 3.576

3.  Effect of three types of horseshoes and unshod feet on selected non-podal forelimb kinematic variables measured by an extremity mounted inertial measurement unit sensor system in sound horses at the trot under conditions of treadmill and soft geotextile surface exercise.

Authors:  Joëlle Christina Stutz; Beatriz Vidondo; Alessandra Ramseyer; Ugo Ettore Maninchedda; Antonio M Cruz
Journal:  Vet Rec Open       Date:  2018-06-18

4.  Fetlock Joint Angle Pattern and Range of Motion Quantification Using Two Synchronized Wearable Inertial Sensors per Limb in Sound Horses and Horses with Single Limb Naturally Occurring Lameness.

Authors:  Eleonora Pagliara; Maddalena Marenchino; Laura Antenucci; Mario Costantini; Giacomo Zoppi; Mario Dante Lucio Giacobini; Michela Bullone; Barbara Riccio; Andrea Bertuglia
Journal:  Vet Sci       Date:  2022-08-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.