Ultrasound-assisted dispersive extraction for the high pressure liquid chromatographic determination of tetracyclines residues in milk with diode array detection.

Eftichia Karageorgou1, Marina Armeni1, Ioulia Moschou1, Victoria Samanidou2.   

Abstract

Ultrasound assisted matrix solid phase dispersive extraction was applied for the selective isolation and clean-up of tetracyclines (oxytetracycline, tetracycline, epi-chlorotetracycline, chlorotetracycline and doxycycline) from milk. Target analytes were determined by an accurate and sensitive chromatographic analytical method, which was validated to meet the European Legislation criteria. The separation was performed on a LiChroCART-LiChrospher® 100 RP-18 (5μm, 250×4mm) analytical column, operated at ambient temperature, followed by diode array detection. Validation included investigation of linearity, selectivity, stability, limits of detection and quantitation, decision limit, detection capability, trueness, precision and ruggedness according to the Youden's approach. Limits of quantitation of examined tetracyclines were from 14.5 to 56.6μg/kg significantly lower than respective Maximum Residue Limits, whereas recoveries ranged from 82.0% to 108%. The applicability of the method was evaluated using milk samples purchased from local market. Accuracy of the method was additionally proved by analysis of bovine milk certified reference material (BCR®-492).
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Chromatography; Dispersion; Milk; Tetracyclines; Ultrasound

Mesh:

Substances:

Year:  2013        PMID: 24360458     DOI: 10.1016/j.foodchem.2013.11.008

Source DB:  PubMed          Journal:  Food Chem        ISSN: 0308-8146            Impact factor:   7.514


  6 in total

1.  An experimental design for the optimization of the extraction methods of metallic mobile fractions from environmental solid samples.

Authors:  Gabriela Geanina Vasile; Dana Elena Popa; Mihaela Buleandră; Iulia Gabriela David
Journal:  Environ Monit Assess       Date:  2018-09-26       Impact factor: 2.513

2.  Qualitative immunoassay for the determination of tetracycline antibiotic residues in milk samples followed by a quantitative improved HPLC-DAD method.

Authors:  Moneera N Alnassrallah; Nourah Z Alzoman; Aliyah Almomen
Journal:  Sci Rep       Date:  2022-08-25       Impact factor: 4.996

3.  Analysis of Tetracyclines in Medicated Feed for Food Animal Production by HPLC-MS/MS.

Authors:  Rosa Elvira Gavilán; Carolina Nebot; Jose Manuel Miranda; Yolanda Martín-Gómez; Beatriz Vázquez-Belda; Carlos Manuel Franco; Alberto Cepeda
Journal:  Antibiotics (Basel)       Date:  2015-12-24

Review 4.  Molecularly Imprinted Polymers as Extracting Media for the Chromatographic Determination of Antibiotics in Milk.

Authors:  Dimitrios Bitas; Victoria Samanidou
Journal:  Molecules       Date:  2018-02-02       Impact factor: 4.411

Review 5.  Antibiotic residues in milk: Past, present, and future.

Authors:  Sabbya Sachi; Jannatul Ferdous; Mahmudul Hasan Sikder; S M Azizul Karim Hussani
Journal:  J Adv Vet Anim Res       Date:  2019-07-11

Review 6.  Green Bioanalytical Applications of Graphene Oxide for the Extraction of Small Organic Molecules.

Authors:  Natalia Manousi; Orfeas-Evangelos Plastiras; Eleni A Deliyanni; George A Zachariadis
Journal:  Molecules       Date:  2021-05-09       Impact factor: 4.411