Automatic detection of end QRS notching or slurring.

Elaine N Clark1, Ibraheem Katibi2, Peter W Macfarlane3.   

Abstract

The purpose of this study was to define criteria suited to automated detection of end QRS notching and slurring and to evaluate their accuracy. One hundred resting 12 lead ECGs from young adult men, split randomly into equal training and test sets, were examined independently by two reviewers for the presence of such notching or slurring. Consensus was reached by re-examination. Logic was added to the Glasgow resting ECG program to automate the detection of the phenomenon. After training, the automated detection had a sensitivity (SE) of 92.1% and a specificity (SP) of 96.6%. For the test set, SE was 90.5%, SP 96.5%. Two populations of healthy subjects--one Caucasian, one Nigerian--were analysed using the automated method. The prevalence of notching/slurring with peak/onset amplitude respectively ≥ 0.1 mV in two contiguous inferolateral leads was 23% and 29% respectively. In conclusion, the detection of end QRS notching or slurring can be automated with a high degree of accuracy.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Automated ECG; Early repolarization; Racial differences

Mesh:

Year:  2013        PMID: 24360346     DOI: 10.1016/j.jelectrocard.2013.10.007

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  3 in total

1.  Sensitivity and specificity of automated detection of early repolarization in standard 12-lead electrocardiography.

Authors:  Tuomas Kenttä; Kimmo Porthan; Jani T Tikkanen; Heikki Väänänen; Lasse Oikarinen; Matti Viitasalo; Hannu Karanko; Maarit Laaksonen; Heikki V Huikuri
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-11-04       Impact factor: 1.468

2.  Autodetection of J Wave Based on Random Forest with Synchrosqueezed Wavelet Transform.

Authors:  Dengao Li; Xinyan Liu; Jumin Zhao; Jie Zhou
Journal:  Biomed Res Int       Date:  2018-07-03       Impact factor: 3.411

3.  Prevalence of ECGs Exceeding Thresholds for ST-Segment-Elevation Myocardial Infarction in Apparently Healthy Individuals: The Role of Ethnicity.

Authors:  C Cato Ter Haar; Jan A Kors; Ron J G Peters; Michael W T Tanck; Marieke B Snijder; Arie C Maan; Cees A Swenne; Bert-Jan H van den Born; Jonas S S G de Jong; Peter W Macfarlane; Pieter G Postema
Journal:  J Am Heart Assoc       Date:  2020-06-23       Impact factor: 5.501

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.