Literature DB >> 24360254

In vivo remodeling potential of a novel bioprosthetic tricuspid valve in an ovine model.

Anna M Fallon1, Traci T Goodchild2, James L Cox3, Robert G Matheny4.   

Abstract

OBJECTIVES: A novel bioprosthetic tricuspid valve was constructed from an acellular extracellular matrix (ECM) bioscaffold. The valve's mechanical functionality and potential for histologic regeneration was evaluated in an ovine model.
METHODS: The native tricuspid valves of 4 domestic sheep were excised and replaced with bioprosthetic valves constructed from the ECM bioscaffold material shaped into the form of a tube. In vivo function was assessed over time by transthoracic echocardiography. Animals were euthanized at 3, 5, 8, and 12 months after valve implantation, and explanted valves were examined for gross morphology and by qualitative histopathologic analysis.
RESULTS: All 4 sheep survived until the specified date. Forward flow by echocardiography was normal with trivial to mild regurgitation. Annular morphology and mobility of the leaflets appeared normal with excellent leaflet coaptation. Explanted valves were grossly normal at all time points and showed evidence of progressive tissue remodeling and integration at the host-tissue interface. Histopathologic analysis demonstrated massive host-cell infiltration, structural reorganization of the ECM bioscaffold, elastin generation at the annulus by 3 months, and increased collagen organization and glycosaminoglycan presence in the leaflets by 5 months, with no evidence of foreign body response.
CONCLUSIONS: When implanted in the form of a tubular valve, the acellular ECM bioscaffold demonstrates feasibility as a biomechanically sound bioprosthetic tricuspid valve replacement with evidence of progressive endothelialization and constructive tissue remodeling.
Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24360254     DOI: 10.1016/j.jtcvs.2013.10.048

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  11 in total

Review 1.  Small intestinal submucosa extracellular matrix (CorMatrix®) in cardiovascular surgery: a systematic review.

Authors:  Zahra Mosala Nezhad; Alain Poncelet; Laurent de Kerchove; Pierre Gianello; Caroline Fervaille; Gebrine El Khoury
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-02-23

Review 2.  The Heart and Great Vessels.

Authors:  Ekene Onwuka; Nakesha King; Eric Heuer; Christopher Breuer
Journal:  Cold Spring Harb Perspect Med       Date:  2018-03-01       Impact factor: 6.915

Review 3.  Next-generation tissue-engineered heart valves with repair, remodelling and regeneration capacity.

Authors:  Emanuela S Fioretta; Sarah E Motta; Valentina Lintas; Sandra Loerakker; Kevin K Parker; Frank P T Baaijens; Volkmar Falk; Simon P Hoerstrup; Maximilian Y Emmert
Journal:  Nat Rev Cardiol       Date:  2020-09-09       Impact factor: 32.419

4.  Heart valve scaffold fabrication: Bioinspired control of macro-scale morphology, mechanics and micro-structure.

Authors:  Antonio D'Amore; Samuel K Luketich; Giuseppe M Raffa; Salim Olia; Giorgio Menallo; Antonino Mazzola; Flavio D'Accardi; Tamir Grunberg; Xinzhu Gu; Michele Pilato; Marina V Kameneva; Vinay Badhwar; William R Wagner
Journal:  Biomaterials       Date:  2017-10-06       Impact factor: 12.479

Review 5.  Advances in the treatment of aortic valve disease: is it time for companion diagnostics?

Authors:  Robert B Hinton
Journal:  Curr Opin Pediatr       Date:  2014-10       Impact factor: 2.856

6.  Bioactive Anti-Thrombotic Modification of Decellularized Matrix for Vascular Applications.

Authors:  Jeremy J Glynn; Monica T Hinds
Journal:  Adv Healthc Mater       Date:  2016-04-13       Impact factor: 9.933

7.  Scar Size and Other Parameters for Tracking Left Ventricular Dysfunction after Induction of Myocardial Infarcts in Sheep (Ovisaries).

Authors:  Hylton P Gordon; Michael G Katz; Anthony S Fargnoli; Virginia L Gillespie; Roger J Hajjar; Charles R Bridges
Journal:  Comp Med       Date:  2018-05-10       Impact factor: 0.982

Review 8.  Antibiotic-Eluting Envelopes to Prevent Cardiac-Implantable Electronic Device Infection: Past, Present, and Future.

Authors:  Kun Xiang; John N Catanzaro; Claude Elayi; Zerelda Esquer Garrigos; Muhammad R Sohail
Journal:  Cureus       Date:  2021-02-02

9.  Preclinical evaluation of efficacy and pharmacokinetics of gentamicin containing extracellular-matrix envelope.

Authors:  M Rizwan Sohail; Zerelda Esquer Garrigos; Claude S Elayi; Kun Xiang; John N Catanzaro
Journal:  Pacing Clin Electrophysiol       Date:  2020-03-05       Impact factor: 1.976

10.  Pathological Changes of Adult Mitral Valves after Failed CorMatrix ECM Repair.

Authors:  Baidarbhi Chakraborty; He Wang
Journal:  J Clin Transl Pathol       Date:  2021-08-24
View more