Literature DB >> 24360008

A clinical comparison of cordless and conventional displacement systems regarding clinical performance and impression quality.

Özlem Acar1, Selim Erkut2, Tuncer Burak Özçelik3, Erdem Ozdemır4, Mehtap Akçil5.   

Abstract

STATEMENT OF PROBLEM: It is not clear whether newly introduced cordless displacement systems are better able to manage gingiva than conventional systems.
PURPOSE: The purpose of this in vivo study was to evaluate the gingival management ability of 4 different displacement methods with a standardized subgingival preparation finish line.
MATERIAL AND METHODS: The effects of 4 displacement techniques on gingival management and impression quality were evaluated by means of 6 evaluation criteria. A subgingival preparation finish line of between 1 and 2 mm was ensured, and the buccal aspects of 252 (n=63) teeth were clinically assessed for ease of application, time spent, bleeding, remnants, and dilatation. The complete reproduction of the preparation finish line and the bubble and void formations on polyether impressions were also evaluated. The data were statistically analyzed with the χ(2) test (α=.05). The Bonferroni correction was used to control Type I error for the pairwise comparison groups (α=.008).
RESULTS: Statistically significant differences were found for all criteria among the groups (P<.05). The nonimpregnated displacement cord group was the least effective group in terms of bleeding and impression quality (P<.008). The aluminum chloride impregnated cord group and the displacement paste with cap group were found to be comparable in terms of remnants, dilatation, and impression quality (P>.008). The retraction cap with paste group showed better results for ease of application, time spent, and bleeding than the aluminum chloride impregnated cord group (P<.008). Although the group with aluminum chloride impregnated cord, displacement paste, and cap showed better results for dilatation, it was time consuming and difficult (P<.008).
CONCLUSIONS: Except for the nonimpregnated cord group, all of the groups were comparable and clinically useful, with perfect or acceptable impression qualities.
Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24360008     DOI: 10.1016/j.prosdent.2013.08.009

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  Impression Techniques Used for Single-Unit Crowns: Findings from the National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; David R Louis; Mark S Litaker; Helena M Minyé; Thomas Oates; Valeria V Gordan; Don G Marshall; Cyril Meyerowitz; Gregg H Gilbert
Journal:  J Prosthodont       Date:  2017-01-11       Impact factor: 2.752

2.  Impression evaluation and laboratory use for single-unit crowns: Findings from The National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; Mark S Litaker; Ashley J George; Scott Durand; Sepideh Malekpour; Don G Marshall; Cyril Meyerowitz; Lauren Carter; Valeria V Gordan; Gregg H Gilbert
Journal:  J Am Dent Assoc       Date:  2017-08-16       Impact factor: 3.634

3.  Clinical acceptance of single-unit crowns and its association with impression and tissue displacement techniques: Findings from the National Dental Practice-Based Research Network.

Authors:  Nathaniel C Lawson; Mark S Litaker; Ellen Sowell; Valeria V Gordan; Rahma Mungia; Kenneth R Ronzo; Ba T Lam; Gregg H Gilbert; Michael S McCracken
Journal:  J Prosthet Dent       Date:  2019-10-04       Impact factor: 3.426

4.  Comparative Evaluation of the Amount of Gingival Displacement Using Three Recent Gingival Retraction Systems - In vivo Study.

Authors:  Siddique Mohammed Qureshi; Nayana Shriram Anasane; Dilip Kakade
Journal:  Contemp Clin Dent       Date:  2020-07-13

5.  A comparative evaluation of amount of gingival displacement produced by four different gingival displacement agents - An in vivo study.

Authors:  Zainab Ilyas Kesari; Jyoti Tipin Karani; Saloni Sharad Mistry; Ashutosh Ramesh Pai
Journal:  J Indian Prosthodont Soc       Date:  2019-10-10

6.  Minimum intervention management of diastema closure using cordless displacement system and laminate veneers: A 2-year follow-up.

Authors:  Ana Teresa Maluly-Proni; Bruna Oliveira-Reis; Wirley Gonçalves Assunção; Paulo Henrique Dos Santos
Journal:  Eur J Dent       Date:  2018 Jul-Sep
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.