| Literature DB >> 24359790 |
Annette Röttger1, Anja Honig2, Diana Linzmaier2.
Abstract
The upcoming revision of Council Directive 96/29/Euratom in the form of the proposed basic safety standards for protection against the dangers arising from exposure to ionizing radiation (BSS) evokes new challenges for the metrology institutes. In the case of the two radon isotopes, the corresponding public exposure will be part of legal metrology for the first time. Since the levels of activity concentration that are laid down in the draft of the BSS cover the range from 200 Bq/m(3) to 300 Bq/m(3) in general (with an exceptional top level of 1000 Bq/m(3)), new calibration procedures for existing commercial monitors with their limited counting statistic have to be developed. This paper gives an overview how this metrological challenge can be overcome.Keywords: Calibration; Emanation; Metrology; Radon; Reference atmospheres; Thoron
Mesh:
Substances:
Year: 2013 PMID: 24359790 DOI: 10.1016/j.apradiso.2013.11.111
Source DB: PubMed Journal: Appl Radiat Isot ISSN: 0969-8043 Impact factor: 1.513