| Literature DB >> 24359603 |
Blair A Williams1, Martin J Bullock, Jonathan R Trites, S Mark Taylor, Robert D Hart.
Abstract
BACKGROUND: Fine needle aspiration (FNA) of thyroid nodules is a cornerstone of surgical decision making in thyroid cancer. The most widely utilized system for reporting thyroid FNA results is the Bethesda System, which includes predicted malignancy rates for each FNA category. To date there have been few studies to determine whether these predictions are widely applicable.Entities:
Mesh:
Year: 2013 PMID: 24359603 PMCID: PMC3878187 DOI: 10.1186/1916-0216-42-61
Source DB: PubMed Journal: J Otolaryngol Head Neck Surg ISSN: 1916-0208
The distribution of thyroid FNAs by diagnostic category, with percentage in parentheses
| Unsatisfactory | 431 (28.9) |
| Benign | 681 (45.7) |
| Abnormal | 281 (18.8) |
| SFN | 65 (4.4) |
| SFM | 19 (1.3) |
| Malignant | 14 (0.9) |
FNA – fine needle aspiration, SFN – Suspicious for Neoplasm, SFM – Suspicious for Malignancy.
Correlation of FNA category to surgical pathology and overall malignancy rate for each category
| Unsatisfactory | 14.5 | 0.0 | 0.0 | 3.6 | 18.2 |
| Benign | 14.9 | 0.0 | 0.0 | 1.1 | 16.0 |
| Abnormal | 22.2 | 1.2 | 0.6 | 0.6 | 24.7 |
| SFN | 23.9 | 6.5 | 0.0 | 2.2 | 32.6 |
| SFM | 76.5 | 0.0 | 11.8 | 5.9 | 94.1 |
| Malignant | 100.0 | 0.0 | 0.0 | 0.0 | 100.0 |
Values are expressed as percentages of all FNAs in each category. FNA – fine needle aspiration, SFN – Suspicious for Neoplasm, SFM – Suspicious for Malignancy.
Comparison of FNA diagnoses between this study and the published values in other studies, expressed as a percentage of all FNAs
| Unsatisfactory | 28.9 | 10.4 | 18.6 | 20.1 |
| Benign | 45.7 | 64.6 | 59.0 | 39.0 |
| Abnormal | 18.8 | 3.2 | 3.4 | 27.2 |
| SFN | 4.4 | 11.6 | 9.7 | 8.4 |
| SFM | 1.3 | 2.6 | 2.3 | 2.6 |
| Malignant | 0.9 | 7.6 | 7.0 | 2.7 |
FNA – fine needle aspiration, SFN – Suspicious for Neoplasm, SFM – Suspicious for Malignancy.
Comparison of malignancy rates by FNA category among this study, the Bethesda System, and published values in other studies
| Unsatisfactory | 18.2 | 1-4 | 10.9 | 8.9 | 14 |
| Benign | 16.0 | 0-3 | 7.3 | 6.5 | 3 |
| Abnormal | 24.7 | 5-15 | 13.5 | 17 | 6 |
| SFN | 32.6 | 15-30 | 32.2 | 25.4 | 22 |
| SFM | 94.1 | 60-75 | 64.7 | 70 | 56 |
| Malignant | 100.0 | 97-99 | 98.6 | 98.1 | 100 |
| Overall | 28.4 | -- | 45.3 | 31.3 | 29.0 |
FNA – fine needle aspiration, SFN – Suspicious for Neoplasm, SFM – Suspicious for Malignancy.
Figure 1Comparison of malignancy rates (in percentages) between the current study. Bethesda System values are given as the midpoint from the reported range. FNA – fine needle aspiration, SFN – Suspicious for Neoplasm, SFM – Suspicious for Malignancy.