PURPOSE: Improved diagnostic sensitivity could be obtained in cancer detection and staging when individual compounds of the choline pool can be detected. Therefore, a novel coil design is proposed, providing the ability to acquire both (1) H and (31) P magnetic resonance spectroscopic imaging (MRSI) in patients with prostate cancer. METHODS: A two-element (1) H/(31) P endorectal coil was designed by adjusting a commercially available 3T endorectal coil. The two-element coil setup was interfaced as a transceiver to a whole body 7T MR scanner. Simulations and phantom measurements were performed to compare the efficiency of the coil. (1) H MRSI and (31) P MRSI were acquired in vivo in prostate cancer patients. RESULTS: The efficiency of the (1) H/(31) P coil is comparable to the dual channel (1) H coil previously published. Individually distinguishable phospholipid metabolites in the in vivo (31) P spectra were: phosphoethanolamine, phosphocholine, phosphate, glycerophosphoethanolamine, glycerophosphocholine, phosphocreatine, and adenosine triposphate. (1) H MRSI was performed within the same scan session, visualizing choline, polyamines, creatine, and citrate. CONCLUSION: (1) H MRSI and (31) P MRSI can be acquired in the human prostate at 7T within the same scan session using an endorectal coil matched and tuned for (1) H (quadrature) and (31) P (linear) without the need of cable traps and with negligible efficiency losses in the (1) H and (31) P channel.
PURPOSE: Improved diagnostic sensitivity could be obtained in cancer detection and staging when individual compounds of the choline pool can be detected. Therefore, a novel coil design is proposed, providing the ability to acquire both (1) H and (31) P magnetic resonance spectroscopic imaging (MRSI) in patients with prostate cancer. METHODS: A two-element (1) H/(31) P endorectal coil was designed by adjusting a commercially available 3T endorectal coil. The two-element coil setup was interfaced as a transceiver to a whole body 7T MR scanner. Simulations and phantom measurements were performed to compare the efficiency of the coil. (1) H MRSI and (31) P MRSI were acquired in vivo in prostate cancerpatients. RESULTS: The efficiency of the (1) H/(31) P coil is comparable to the dual channel (1) H coil previously published. Individually distinguishable phospholipid metabolites in the in vivo (31) P spectra were: phosphoethanolamine, phosphocholine, phosphate, glycerophosphoethanolamine, glycerophosphocholine, phosphocreatine, and adenosine triposphate. (1) H MRSI was performed within the same scan session, visualizing choline, polyamines, creatine, and citrate. CONCLUSION: (1) H MRSI and (31) P MRSI can be acquired in the human prostate at 7T within the same scan session using an endorectal coil matched and tuned for (1) H (quadrature) and (31) P (linear) without the need of cable traps and with negligible efficiency losses in the (1) H and (31) P channel.
Authors: Christian Mirkes; Gunamony Shajan; Grzegorz Chadzynski; Kai Buckenmaier; Benjamin Bender; Klaus Scheffler Journal: MAGMA Date: 2016-01-25 Impact factor: 2.310
Authors: Bart R Steensma; Ingmar Voogt; Abe J van der Werf; Cornelis A T van den Berg; Peter R Luijten; Dennis W J Klomp; Alexander J E Raaijmakers Journal: NMR Biomed Date: 2018-07-18 Impact factor: 4.044
Authors: Stephan Orzada; Klaus Solbach; Marcel Gratz; Sascha Brunheim; Thomas M Fiedler; Sören Johst; Andreas K Bitz; Samaneh Shooshtary; Ashraf Abuelhaija; Maximilian N Voelker; Stefan H G Rietsch; Oliver Kraff; Stefan Maderwald; Martina Flöser; Mark Oehmigen; Harald H Quick; Mark E Ladd Journal: PLoS One Date: 2019-09-12 Impact factor: 3.240
Authors: Bart W J Philips; Mark J van Uden; Stefan H G Rietsch; Stephan Orzada; Tom W J Scheenen Journal: Med Phys Date: 2019-08-01 Impact factor: 4.071
Authors: Bart Steensma; Pierre-Francois van de Moortele; Arcan Ertürk; Andrea Grant; Gregor Adriany; Peter Luijten; Dennis Klomp; Nico van den Berg; Gregory Metzger; Alexander Raaijmakers Journal: Magn Reson Med Date: 2020-05-05 Impact factor: 4.668