Literature DB >> 24357271

(31) P MR spectroscopic imaging combined with (1) H MR spectroscopic imaging in the human prostate using a double tuned endorectal coil at 7T.

Mariska P Luttje1, Michel G M Italiaander, Catalina S Arteaga de Castro, Wybe J M van der Kemp, Peter R Luijten, Marco van Vulpen, Uulke A van der Heide, Dennis W J Klomp.   

Abstract

PURPOSE: Improved diagnostic sensitivity could be obtained in cancer detection and staging when individual compounds of the choline pool can be detected. Therefore, a novel coil design is proposed, providing the ability to acquire both (1) H and (31) P magnetic resonance spectroscopic imaging (MRSI) in patients with prostate cancer.
METHODS: A two-element (1) H/(31) P endorectal coil was designed by adjusting a commercially available 3T endorectal coil. The two-element coil setup was interfaced as a transceiver to a whole body 7T MR scanner. Simulations and phantom measurements were performed to compare the efficiency of the coil. (1) H MRSI and (31) P MRSI were acquired in vivo in prostate cancer patients.
RESULTS: The efficiency of the (1) H/(31) P coil is comparable to the dual channel (1) H coil previously published. Individually distinguishable phospholipid metabolites in the in vivo (31) P spectra were: phosphoethanolamine, phosphocholine, phosphate, glycerophosphoethanolamine, glycerophosphocholine, phosphocreatine, and adenosine triposphate. (1) H MRSI was performed within the same scan session, visualizing choline, polyamines, creatine, and citrate.
CONCLUSION: (1) H MRSI and (31) P MRSI can be acquired in the human prostate at 7T within the same scan session using an endorectal coil matched and tuned for (1) H (quadrature) and (31) P (linear) without the need of cable traps and with negligible efficiency losses in the (1) H and (31) P channel.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  7 Tesla; magnetic resonance spectroscopy; phosphorus; prostate cancer; proton

Mesh:

Substances:

Year:  2013        PMID: 24357271     DOI: 10.1002/mrm.25070

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

Review 1.  Ultra-high-field MR in Prostate cancer: Feasibility and Potential.

Authors:  Carlijn J A Tenbergen; Gregory J Metzger; Tom W J Scheenen
Journal:  MAGMA       Date:  2022-05-17       Impact factor: 2.533

Review 2.  Novel methods for mapping the cavernous nerves during radical prostatectomy.

Authors:  Nathaniel M Fried; Arthur L Burnett
Journal:  Nat Rev Urol       Date:  2015-08       Impact factor: 14.432

3.  (31)P CSI of the human brain in healthy subjects and tumor patients at 9.4 T with a three-layered multi-nuclear coil: initial results.

Authors:  Christian Mirkes; Gunamony Shajan; Grzegorz Chadzynski; Kai Buckenmaier; Benjamin Bender; Klaus Scheffler
Journal:  MAGMA       Date:  2016-01-25       Impact factor: 2.310

4.  Design of a forward view antenna for prostate imaging at 7 T.

Authors:  Bart R Steensma; Ingmar Voogt; Abe J van der Werf; Cornelis A T van den Berg; Peter R Luijten; Dennis W J Klomp; Alexander J E Raaijmakers
Journal:  NMR Biomed       Date:  2018-07-18       Impact factor: 4.044

5.  A 32-channel parallel transmit system add-on for 7T MRI.

Authors:  Stephan Orzada; Klaus Solbach; Marcel Gratz; Sascha Brunheim; Thomas M Fiedler; Sören Johst; Andreas K Bitz; Samaneh Shooshtary; Ashraf Abuelhaija; Maximilian N Voelker; Stefan H G Rietsch; Oliver Kraff; Stefan Maderwald; Martina Flöser; Mark Oehmigen; Harald H Quick; Mark E Ladd
Journal:  PLoS One       Date:  2019-09-12       Impact factor: 3.240

6.  A multitransmit external body array combined with a 1 H and 31 P endorectal coil to enable a multiparametric and multimetabolic MRI examination of the prostate at 7T.

Authors:  Bart W J Philips; Mark J van Uden; Stefan H G Rietsch; Stephan Orzada; Tom W J Scheenen
Journal:  Med Phys       Date:  2019-08-01       Impact factor: 4.071

7.  Introduction of the snake antenna array: Geometry optimization of a sinusoidal dipole antenna for 10.5T body imaging with lower peak SAR.

Authors:  Bart Steensma; Pierre-Francois van de Moortele; Arcan Ertürk; Andrea Grant; Gregor Adriany; Peter Luijten; Dennis Klomp; Nico van den Berg; Gregory Metzger; Alexander Raaijmakers
Journal:  Magn Reson Med       Date:  2020-05-05       Impact factor: 4.668

8.  A Crosstalk- and Interferent-Free Dual Electrode Amperometric Biosensor for the Simultaneous Determination of Choline and Phosphocholine.

Authors:  Rosanna Ciriello; Antonio Guerrieri
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.576

9.  Comparing signal-to-noise ratio for prostate imaging at 7T and 3T.

Authors:  Bart R Steensma; Mariska Luttje; Ingmar J Voogt; Dennis W J Klomp; Peter R Luijten; Cornelis A T van den Berg; Alexander J E Raaijmakers
Journal:  J Magn Reson Imaging       Date:  2018-10-22       Impact factor: 4.813

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.