Literature DB >> 24357101

A sensitive LC-MS/MS method for simultaneous determination of R-bambuterol and its active metabolite R-terbutaline in human plasma and urine with application to a clinical pharmacokinetic study.

Ting Zhou1, Ting Zhao, Qing Cheng, Shan Liu, Ling Xu, Wen Tan.   

Abstract

A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of R-bambuterol and its active metabolite R-terbutaline in human plasma and urine was established. The inhibition for the biotransformation of R-bambuterol in plasma was fully investigated. Plasma samples were prepared on ice and neostigmine metilsulfate added as a cholinesterase inhibitor immediately after sample collection. All samples were extracted with ethyl acetate and separated on a C₁₈ column under gradient elution with a mobile phase consisting of methanol and water containing 5 mm ammonium acetate at a flow rate of 0.6 mL/min. The analytes were detected by an API 4000 tandem mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode. The established method was highly sensitive with the lower limit of quantification (LLOQ) of 10.00 pg/mL for each analyte in plasma. In urine samples, the LLOQs were 20.00 and 500.0 pg/mL for R-bambuterol and R-terbutaline, respectively. The intra- and inter-day precisions were <12.7 and <8.6% for plasma and urine, respectively. The analytical runtime within 6.0 min per sample made this method suitable for high-throughput determination. The validated method has been successfully applied to the human pharmacokinetic study of R-bambuterol involving 10 healthy volunteers.
Copyright © 2013 John Wiley & Sons, Ltd.

Entities:  

Keywords:  LC-MS/MS; R-bambuterol; R-terbutaline; pharmacokinetics

Mesh:

Substances:

Year:  2013        PMID: 24357101     DOI: 10.1002/bmc.3107

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  2 in total

1.  Chemical fingerprinting and quantitative monitoring of the doping drugs bambuterol and terbutaline in human urine samples using ATR-FTIR coupled with a PLSR chemometric tool.

Authors:  Faisal K Algethami; Sherif M Eid; Khadiga M Kelani; Mohamed R Elghobashy; Mohamed K Abd El-Rahman
Journal:  RSC Adv       Date:  2020-02-17       Impact factor: 3.361

2.  Synchronous fluorescence as a green and selective tool for simultaneous determination of bambuterol and its main degradation product, terbutaline.

Authors:  Samah Abo El Abass; Heba Elmansi
Journal:  R Soc Open Sci       Date:  2018-10-31       Impact factor: 2.963

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.