Literature DB >> 24355870

A comparison of tapered and cylindrical miniscrew stability.

Seong-Hun Yoo1, Young-Chel Park1, Chung-Ju Hwang1, Ji-Young Kim1, Eun-Hee Choi2, Jung-Yul Cha3.   

Abstract

OBJECTIVES: This study compared the stability of tapered miniscrews with cylindrical miniscrews. MATERIALS/
METHODS: One hundred and five tapered and 122 cylindrical self-drilling miniscrews were placed into the maxillary and mandibular buccal alveolar areas of 132 patients (43 males and 89 females). The insertion torque and removal torque were measured and Periotest values (PTVs) were recorded at implantation.
RESULTS: The success rates of the tapered and cylindrical miniscrews examined were similar. In the maxilla, the insertion torque of the tapered miniscrews (8.3 Ncm) was significantly higher than that of the cylindrical miniscrews (6.3 Ncm) (P < 0.05). The PTVs of the tapered miniscrews were statistically significantly lower in the maxilla (P < 0.05). The removal torque values showed no significant difference between the tapered and cylindrical miniscrews in the upper and lower buccal areas (P > 0.05).
CONCLUSIONS: Tapered miniscrews had higher initial stability when compared to cylindrical miniscrews, whereas the clinical success rates and removal torques were similar between the two designs. The long-term stability is not directly affected by the miniscrew design.
© The Author 2013. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2013        PMID: 24355870     DOI: 10.1093/ejo/cjt092

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  6 in total

1.  A prospective, split-mouth, clinical study of orthodontic titanium miniscrews with machined and acid-etched surfaces.

Authors:  Hyo-Jin Park; Sung-Hwan Choi; Yoon Jeong Choi; Young-Bum Park; Kwang-Mahn Kim; Hyung-Seog Yu
Journal:  Angle Orthod       Date:  2018-12-05       Impact factor: 2.079

Review 2.  A Scoping Review about the Characteristics and Success-Failure Rates of Temporary Anchorage Devices in Orthodontics.

Authors:  Daniel Jaramillo-Bedoya; Gustavo Villegas-Giraldo; Andrés A Agudelo-Suárez; Diana Milena Ramírez-Ossa
Journal:  Dent J (Basel)       Date:  2022-05-06

3.  Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles.

Authors:  Sung-Hwan Choi; Seong-Jin Kim; Kee-Joon Lee; Sang-Jin Sung; Youn-Sic Chun; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2016-07-25       Impact factor: 1.372

4.  Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study.

Authors:  Jacek Matys; Rafał Flieger; Gianluca Tenore; Kinga Grzech-Leśniak; Umberto Romeo; Marzena Dominiak
Journal:  Lasers Med Sci       Date:  2017-11-10       Impact factor: 3.161

5.  Investigation of the optimal design of orthodontic mini-implants based on the primary stability: A finite element analysis.

Authors:  Amir Hooman Sadr Haghighi; Vahid Pouyafar; Ali Navid; Mahsa Eskandarinezhad; Tannaz Abdollahzadeh Baghaei
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2019-08-14

6.  The correlation among gripping volume, insertion torque, and pullout strength of micro-implant.

Authors:  Chun-Chan Ting; Kun-Jung Hsu; Szu-Yu Hsiao; Chun-Ming Chen
Journal:  J Dent Sci       Date:  2020-07-16       Impact factor: 2.080

  6 in total