Literature DB >> 24355463

Improved activity of immobilized antibody by paratope orientation controller: probing paratope orientation by electrochemical strategy and surface plasmon resonance spectroscopy.

Wei-Ching Liao1, Ja-An Annie Ho2.   

Abstract

Electrochemical method and surface plasmon resonance (SPR) spectroscopic analysis are utilized herein to investigate antibody immobilization without and with orientation control for site-positioning paratopes (antigen binding site) of the antibody molecules. Biotin and its antibody were selected in current study as model. Such an approach employed thiophene-3-boronic acid (T3BA) as paratope orientation controller, (i) enabled site orientation of the antibody molecules reducing the hiding of paratopes, and (ii) maintained the activity of the captured antibodies, as confirmed by electrochemical and SPR analysis. Anti-biotin antibody (a glycoprotein) was covalently bound to a self-assembled monolayer of T3BA modified on a nanogold-electrodeposited screen-printed electrode through boronic acid-saccharide interactions, with the boronic acid units specifically binding to the glycosylation sites of the antibody molecules. The immunosensor functioned based on competition between the analyte biotin and biotin-tagged, potassium hexacyanoferrate(II)-encapsulated liposomes. The current signal produced by the released liposomal Fe(CN)6(4-), measured using square wave voltammetry, yielded a sigmoidally shaped dose-response curve that was linear over eight orders of magnitude (from 10(-11) to 10(-3)M). Furthermore this biosensing system fabricated based on T3BA approach was found to possess significantly improved sensitivity, and the limit of detection toward biotin was calculated as 0.102 ng mL(-1) (equivalent to 6 μL of 4.19 × 10(-10)M biotin).
© 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Boronate affinity; Electrochemistry; Immunosensor; SPR analysis; Site-oriented immobilization

Mesh:

Substances:

Year:  2013        PMID: 24355463     DOI: 10.1016/j.bios.2013.10.054

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  Screen Printed Carbon Electrode Based Electrochemical Immunosensor for the Detection of Dengue NS1 Antigen.

Authors:  Om Parkash; Chan Yean Yean; Rafidah Hanim Shueb
Journal:  Diagnostics (Basel)       Date:  2014-11-20

Review 2.  Plasmonics for Biosensing.

Authors:  Xue Han; Kun Liu; Changsen Sun
Journal:  Materials (Basel)       Date:  2019-04-30       Impact factor: 3.623

  2 in total