Literature DB >> 24355458

Development of stable and reproducible biosensors based on electrochemical impedance spectroscopy: three-electrode versus two-electrode setup.

Luca Ianeselli1, Gianluca Grenci2, Carlo Callegari3, Massimo Tormen2, Loredana Casalis4.   

Abstract

This work focuses on the development of electrochemical impedance biosensors based on capacitance readout, for the detection of biomolecules in small sample volumes. We performed electrochemical impedance spectroscopy (EIS) measurements of DNA hybridization in electrochemical cells with microfabricated gold electrodes. The time stability of the device was tested in two different configurations: two microelectrodes in a microfluidic channel; two microelectrodes plus a reference electrode in an electrochemical cell. Our results demonstrate that the three-electrode setup is more stable, more reproducible, and suitable for real-time measurements. In the last part of the work we perform a test study of DNA hybridization in real time, and we show that the three-electrode configuration can measure the process in situ and in real time.
© 2013 Elsevier B.V. All rights reserved.

Keywords:  DNA hybridization; DNA self-assembling; EIS; Real-time biosensors

Mesh:

Substances:

Year:  2013        PMID: 24355458     DOI: 10.1016/j.bios.2013.11.067

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Label-free detection of missense mutations and methylation differences in the p53 gene using optically diffracting hydrogels.

Authors:  Kelsey I MacConaghy; Duncan M Chadly; Mark P Stoykovich; Joel L Kaar
Journal:  Analyst       Date:  2015-09-21       Impact factor: 4.616

2.  Electrochemical Resistive DNA Biosensor for the Detection of HPV Type 16.

Authors:  José R Espinosa; Marisol Galván; Arturo S Quiñones; Jorge L Ayala; Verónica Ávila; Sergio M Durón
Journal:  Molecules       Date:  2021-06-05       Impact factor: 4.411

3.  Mismatch detection in DNA monolayers by atomic force microscopy and electrochemical impedance spectroscopy.

Authors:  Maryse D Nkoua Ngavouka; Pietro Capaldo; Elena Ambrosetti; Giacinto Scoles; Loredana Casalis; Pietro Parisse
Journal:  Beilstein J Nanotechnol       Date:  2016-02-09       Impact factor: 3.649

4.  A Microelectrode Array with Reproducible Performance Shows Loss of Consistency Following Functionalization with a Self-Assembled 6-Mercapto-1-hexanol Layer.

Authors:  Damion K Corrigan; Vincent Vezza; Holger Schulze; Till T Bachmann; Andrew R Mount; Anthony J Walton; Jonathan G Terry
Journal:  Sensors (Basel)       Date:  2018-06-09       Impact factor: 3.576

Review 5.  Recent Advances in Electrochemical and Optical Biosensors Designed for Detection of Interleukin 6.

Authors:  Munezza Ata Khan; Mohammad Mujahid
Journal:  Sensors (Basel)       Date:  2020-01-23       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.