Manufacturer changes lead to clinically important differences between two editions of the TNO stereotest.

Louise L A van Doorn1, Bruce J W Evans, David F Edgar, Marten F Fortuin.   

Abstract

PURPOSE: Stereoacuity tests used in clinical practice should be repeatable and reproducible. However, it has been observed in a clinical setting that new editions of the TNO stereotest appear to give different values from those obtained using previous versions. The purpose of the present research was to investigate this observation.
METHODS: One hundred and twenty-one Dutch subjects, 88 (73%) females and 33 (27%) males, with an average age of 34.0 years (range 18-55) had their stereoacuity measured using two different versions of the TNO stereoacuity test (TNO 13 and TNO 15). The TNO was tested in a counterbalanced order so that consecutive subjects started with alternate editions to avoid bias.
RESULTS: There was a significant difference (p < 0.001) between the median value for stereoacuity measured with TNO 13 (30 s of arc) and TNO 15 (60 s of arc). The bias between the two test versions was -0.23 Log arcseconds (95% limits of the differences: 0.15 to -0.60 Log arcseconds).
CONCLUSION: This study reveals that results obtained with two different editions of a commonplace stereoacuity test are not comparable. New versions come on the market at regular intervals and the assumption that they will give the same results as previous versions may not be valid. Besides the statistically significant difference between the TNO 13 and TNO 15, the Bland-Altman plot also showed a considerable bias and the 95% limits of the differences between the TNO 13 and TNO 15 are more than two steps on the Log arcsecond scale. This difference between two editions of the TNO stereotests is not clinically acceptable and therefore it is inappropriate to use the two versions of the test interchangeably. It is important in both research and clinical records to specify the edition of the TNO test used.
© 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

Entities:  

Keywords:  TNO stereotest; reproducibility; stereoacuity; stereopsis; stereoscopic vision

Mesh:

Year:  2013        PMID: 24355036     DOI: 10.1111/opo.12101

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  13 in total

1.  Identifying visual stress during a routine eye examination.

Authors:  Laura Monger; Arnold Wilkins; Peter Allen
Journal:  J Optom       Date:  2014-11-11

2.  Effect of chromatic contrast on stereoacuity measurement with computer-aided three-dimensional technology.

Authors:  Lingzhi Zhao; Huang Wu
Journal:  Ann Transl Med       Date:  2019-05

3.  Stereoacuity measurement using an auto-stereoscopic smartphone.

Authors:  Lingzhi Zhao; Huang Wu
Journal:  Ann Transl Med       Date:  2019-08

4.  Effects of Target Size and Test Distance on Stereoacuity.

Authors:  Yo Iwata; Fusako Fujimura; Tomoya Handa; Nobuyuki Shoji; Hitoshi Ishikawa
Journal:  J Ophthalmol       Date:  2016-08-21       Impact factor: 1.909

5.  Overestimation of stereo thresholds by the TNO stereotest is not due to global stereopsis.

Authors:  Kathleen Vancleef; Jenny C A Read; William Herbert; Nicola Goodship; Maeve Woodhouse; Ignacio Serrano-Pedraza
Journal:  Ophthalmic Physiol Opt       Date:  2017-03-23       Impact factor: 3.117

6.  Stereoacuity of Black-White and Red-Green Patterns in Individuals with and without Color Deficiency.

Authors:  Ying Sun; Huang Wu; Yinghong Qiu; Zhiqiang Yue
Journal:  J Ophthalmol       Date:  2018-08-01       Impact factor: 1.909

7.  Evaluating stereoacuity with 3D shutter glasses technology.

Authors:  Huang Wu; Han Jin; Ying Sun; Yang Wang; Min Ge; Yang Chen; Yunfeng Chi
Journal:  BMC Ophthalmol       Date:  2016-04-26       Impact factor: 2.209

Review 8.  Stereopsis: are we assessing it in enough depth?

Authors:  Anna R O'Connor; Laurence P Tidbury
Journal:  Clin Exp Optom       Date:  2018-01-27       Impact factor: 2.742

9.  Screening for Stereopsis of Children Using an Autostereoscopic Smartphone.

Authors:  Yanhui Yang; Huang Wu
Journal:  J Ophthalmol       Date:  2019-10-31       Impact factor: 1.909

10.  The difference of distance stereoacuity measured with different separating methods.

Authors:  Lingzhi Zhao; Yu Zhang; Huang Wu; Jun Xiao
Journal:  Ann Transl Med       Date:  2020-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.