Literature DB >> 24354902

Indoor air quality and thermal comfort in temporary houses occupied after the Great East Japan Earthquake.

N Shinohara1, M Tokumura, M Kazama, Y Yonemoto, M Yoshioka, N Kagi, K Hasegawa, H Yoshino, U Yanagi.   

Abstract

UNLABELLED: Thermal conditions and indoor concentrations of aldehydes, volatile organic compounds (VOCs), and NO2 were investigated in 19 occupied temporary houses in 15 temporary housing estates constructed in Minamisoma City, Fukushima, Japan. The data were collected in winter, spring, and summer in January to July 2012. Thermal conditions in temporary log houses in the summer were more comfortable than those in pre-fabricated houses. In the winter, the indoor temperature was uncomfortably low in all of the houses, particularly the temporary log houses. Indoor air concentrations for most aldehydes and VOCs were much lower than the indoor guidelines, except for those of p-dichlorobenzene, acetaldehyde, and total VOCs. The indoor p-dichlorobenzene concentrations exceeded the guideline (240 μg/m(3)) in 18% of the temporary houses, and the 10(-3) cancer risk level (91 μg/m(3)) was exceeded in winter in 21% due to use of moth repellents by the occupants. Indoor acetaldehyde concentrations exceeded the guideline (48 μg/m(3) ) in about half of the temporary houses, likely originating from the wooden building materials. Indoor NO2 concentrations in the temporary houses were significantly higher in houses where combustion heating appliances were used (0.17 ± 0.11 ppm) than in those where they were not used (0.0094 ± 0.0065 ppm). PRACTICAL IMPLICATIONS: In the winter, log-house-type temporary houses are comfortable in terms of humidity, dew condensation, and fungi based on the results of questionnaires and measurements, whereas pre-fabricated temporary houses are more comfortable in terms of temperature. In the summer, log-house-type temporary houses are comfortable in terms of temperature and humidity. More comfortable temporary housing in terms of temperature and humidity year-round is needed. Indoor air concentrations of p-dichlorobenzene and NO2 were quite high in some temporary houses due to occupants’ activities, such as use of moth repellents and combustion heating appliances. The government should provide recommendations for safe use of temporary houses by occupants.
© 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Aldehydes; Great East Japan Earthquake; Nitrogen dioxide; Temporary house; Thermal comfort; Volatile organic compound

Mesh:

Substances:

Year:  2014        PMID: 24354902     DOI: 10.1111/ina.12082

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  1 in total

1.  Comparison of the volatile organic compound recovery rates of commercial active samplers for evaluation of indoor air quality in work environments.

Authors:  Yuichi Miyake; Masahiro Tokumura; Qi Wang; Zhiwei Wang; Takashi Amagai
Journal:  Air Qual Atmos Health       Date:  2017-02-18       Impact factor: 3.763

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.