Literature DB >> 24348866

Computed tomography-guided core needle biopsy of lung lesions: Diagnostic yield and correlation between factors and complications.

Ying Wang1, Wentao Li1, Xinhong He1, Guodong Li1, Lichao Xu1.   

Abstract

The aim of the present study was to determine the diagnostic accuracy of computed tomography (CT)-guided core needle biopsy (CNB) and to retrospectively analyze the correlation between the factors and complications of the procedure. Between January 2009 and June 2010, CNB was performed on 345 lung lesions in 343 patients. These patients were then followed up for at least two years. The sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of the CNB diagnoses were calculated. The correlation between factors, such as smoking, positoin and maximal diameter, and the complications of pneumothorax and hemorrhage was analyzed by χ2 test. The sensitivity, specificity, accuracy, PPV and NPV of the CNB diagnoses were 97.3, 100, 97.7, 100 and 87.7%, respectively. A statistically significant correlation was found between pneumothorax and the factors of smoking (P=0.015) and position (P<0.01) and length of the needle in the normal parenchyma (P=0.011), as well as between hemorrhage and the maximal diameter (P=0.005) and length of the needle in the normal parenchyma (P<0.01) and the frequency of needle adjustments (P<0.01). A CT-guided core needle biopsy of the lung lesions provides a high diagnostic yield. Smoking, the decubitus position and a longer length of the needle in the normal parenchyma were found to represent risk factors for a pneumothorax. In addition, a small diameter and longer length of the needle in the normal parenchyma and a more frequent adjustment of the needle were poor predictive factors of hemorrhage.

Entities:  

Keywords:  CT-guided; core needle biopsy; core needle biopsy diagnosis; final diagnosis; hemorrhage; pneumothorax

Year:  2013        PMID: 24348866      PMCID: PMC3861590          DOI: 10.3892/ol.2013.1680

Source DB:  PubMed          Journal:  Oncol Lett        ISSN: 1792-1074            Impact factor:   2.967


Introduction

With the development of computed tomogrphy (CT), an increasing number of lung lesions are detected. It has been reported that >50% of resected pulmonary nodular lesions are related to malignancy; therefore, the requirement for rapid and definite diagnoses of lung lesions has been stressed (1)CT-guided needle biopsy has become the dominant method for obtaining tissue samples from lung lesions in order to obtain a pathological diagnosis (2). The procedure is generally regarded as safe, but pneumothorax, hemorrhage and other rare complications may occur. In addition, the reliability of a benign result remains controversial (3). The objective of the current study was to determine the diagnostic accuracy of CT-guided core needle biopsy (CNB) and to retrospectively analyze the correlation between factors and complications of the procedure.

Materials and methods

Study population

Between January 2009 and June 2010, a CNB was performed on a total of 343 patients with 345 lung lesions in 345 sessions. Among them, two patients received a second CNB, as the size of the tissue sample was not large enough to obtain pathological results. These patients were then followed up for at least two years. The enrolled population consisted of 228 males (66.5%) and 115 females (33.5%). The patient age ranged between 17 and 86 years old (mean age, 60±18.3 years old). The study was approved by the ethics committee of Fudan University (Shanghai, China).

Procedure

Prior to the procedure, the risks and benefits were explained to each patient and informed consent was obtained. Three interventional physicians, each with >5 years experience of needle biopsies, performed the procedures. All cases were performed using the Philips 64-slice spiral CT (120 kV, 250 mA and a 3-mm thickness; Philips Healthcare, Andover, MA, USA) for imaging guidance. The biopsy tool that was used was an automated biopsy gun (SuperCore™, Angiotech Pharmaceuticals, Inc., Vancouver, BC, Canada) with an 18-gauge needle. The patient lay on the CT table and the puncture point and access routine were determined by CT scan. Following local anesthesia, the needle was inserted through the skin and advanced to the lesion. Intra-operative CT scans were performed to confirm the position of the lesion and needle. Once the needle was located in an appropriate position within or near the lesion, the operator triggered the cannula to close, trapping the specimen in the sample notch. Next, the tissue specimen was removed from the notch and sent to the Department of Pathology (Fudan University, Shanghai, China). Immediately after the procedure, a chest CT scan was performed to evaluate procedural complications, including pneumothorax and hemorrhage. In addition, a chest radiograph was obtained the following morning. The baseline characteristics of the lesions and procedures are summarized in Table I.
Table I

Characteristics of lesions and procedures.

Characteristicn (range)
Maximal diameter, mm41.4 (8–134)
Lesion location
 Lobe
  Upper178
  Middle28
  Lower139
 Zone
  Outer54
  Middle114
  Inner177
Patient position
 Supine106
 Prone192
 Decubitus45
Frequency of needle adjustments1.6 (1–7)
Distance from skin puncture to needle tip, mm73.0 (4.8–139.6)
Distance from pleural puncture to needle tip, mm34.4 (8.9–87.8)
Length of needle through normal parenchyma, mm14.8 (0.0–59.7)

Classification of diagnoses and complications

The CNB results were divided into 4 categories: Atypical adenomatous hyperplasia (AAH), malignant, benign and undetermined (3). AAH is a premalignant lesion of lung adenocarcinoma. Although AAH is not ranked as malignant, this category commonly undergoes carcinomatous change. Final diagnoses were divided into 3 categories: Malignant, benign and undetermined. Malignant tumors were defined by: i) Cancer-associated mortality occurring during the follow-up period; ii) lesions representing complete response, partial response or progressive disease to chemotherapy according to the Response Evaluation Criteria in Solid Tumors (4); and iii) a histopathological examination showing malignant tumor tissue in the specimen received at surgical resection. Benign tumors were defined by: i) Lesions that disappeared or decreased in size with conservative treatment; ii) patient exhibited a positive microbiological conclusion (3,5); or iii) a histopathological examination showing no malignant tumor tissue in the specimen from surgical resection. Undetermined tumors were defined as: i) Lesions treated by radiofrequency ablation or stereotactic irradiation (6); ii) a lesion that was stable in size at follow-up; or iii) a patient that could not be contacted for follow-up (Table II).
Table II

CNB and final diagnosis.

Final diagnosis

CNB diagnosisBenignMalignantUndetermined
Benign5079
AAH030
Malignant02506
Undetermined2711

CNB, core needle biopsy; AAH, atypical adenomatous hyperplasia.

AAH and malignant were considered to be positive results and benign was considered a negative result. Positive CNB results were considered true positives if the final diagnosis was malignant or AAH. By contrast, results were considered false positives if the final diagnosis was benign. Negative CNB results were considered true negatives if the final diagnosis was benign and false negatives if the final diagnosis was malignant or AAH (Table III).
Table III

Positive and negative diagnosis.

Final diagnosis

CNB diagnosesPositiveNegativeTotal
Positive2530253
Negative75057
Total26050310

Undetermined CNB diagnoses and final diagnoses were excluded from calculation. CNB, core needle biopsy.

Pneumothorax was graded as mild (lung surface retraction of ≤2 cm; Fig. 1), moderate (lung surface retraction of 2–4 cm) and severe (lung surface retraction of ≥4 cm) (7). Hemorrhage was graded as mild (presenting as haziness along the needle tract; Fig. 2), moderate (hemoptysis of <30 ml or occurrence of patchy haziness around the lesion in CT; Fig. 3) and severe (hemoptysis of ≥30 ml or hemothorax).
Figure 1

CT scan of a 48-year-old female. (A) Pure ground-glass opacity in the right lower lobe for CT examination. The core needle was in an appropriate position for the lesion. (B) Immediately after the biopsy, a mild pneumothorax with lung surface retraction (double arrow) of 1.6 cm was noted.

Figure 2

CT scan image. Mild hemorrhage with haziness along the needle tract.

Figure 3

CT scan of a 54-year-old male. (A) Small nodule (arrow) in the right upper lobe with pleural effusion in the left thoracic cavity, demonstrated to be adenocarcinoma by biopsy and surgery. (B) Immediately after biopsy, a moderate hemorrhage with patchy haziness around the lesion was noted.

Statistical analysis

Data were analyzed with SPSS 19.0; the χ2 test was used for the statistical analysis. The analysis of pneumothorax and hemorrhage was based on the 345 CNB sessions not the 343 patients. P<0.05 was considered to indicate a statistically significant difference.

Results

CNB diagnoses included 66 benign cases, 3 AAH cases, 256 malignant cases and 20 undetermined cases; final diagnoses consisted of 52 benign cases, 267 malignant cases and 26 undetermined cases. Final diagnoses were obtained based on the following characteristics: 11 (3.2%) patients succumbed to cancer-associated mortalities; 64 (18.7%) surgical specimens, 12 (3.5%) positive cultures; 193 (56.2%) positive responses to chemotherapy; 37 (10.8%) tumors disappeared or decreased in size with conservative treatment; 8 (2.3%) lesions were treated with radiofrequency ablation (n=2) or stereotactic irradiation (n=6); 5 (1.5%) lesions were stable during the follow-up period; and 13 (3.8%) patients could not be contacted for follow-up. Following exclusion of the undetermined CNB and final diagnoses (n=35) (8), the number of true positives, false positives, true negatives and false negatives were 253, 0, 50 and 7, respectively. The sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were 97.3, 100, 97.7, 100 and 87.7%, respectively. In the present study, the overall complication rate was 50.4%. There was a total of 60 (17.5%) cases of pneumothorax in the 343 patients. Among those, 52 (15.2%) were mild, 6 (1.7%) were moderate and 2 (0.6%) were severe. Only 5 (1.5%) required placement of chest tubes. There were 113 (32.9%) cases of hemorrhage in this study. Of those, 78 (22.7%) were mild hemorrhage, 35 (10.2%) were moderate hemorrhage. No severe hemorrhage occurred. One of the patients with moderate hemorrhage complained of chest pain and chest tightness 8 h after the biopsy; the chest radiograph indicated a parenchymal hemorrhage and hemocoagulase was administrated. Another patient developed hypotension with syncope, and resuscitation and hemocoagulase administration improved the individual’s condition. All other hemorrhages were self-limited. The correlation between factors and complications was determined, and a statistically significant correlation was found between pneumothorax and the factors of smoking and the position and length of the needle in the normal parenchyma (P=0.011). In addition, a statistically significant correlation existed between hemorrhage and the maximal diameter (P=0.005) and length of the needle in the normal parenchyma (P<0.01) and the frequency of needle adjustments (P<0.01). The correlations between factors and complications are shown in Tables IV and V.
Table IV

Correlation between factors and pneumothorax.

CharacteristicPneumothorax, nNon-pneumothorax, nP-value
Gender0.956
 Male40189
 Female2195
Age, years0.986
 17–491258
 50–6934146
 70–861580
Smoking status0.015a
 Non-smoker1744
 Current or ex-smoker20126
 Unknown24114
Patient position0.000a
 Supine1689
 Prone25170
 Decubitus2025
Lesion location
 Lobe0.568
  Upper29158
  Middle525
  Lower27101
 Zone0.115
  Outer1441
  Middle2486
  Inner23157
Effusion0.181
 No56246
 Yes538
Maximal diameter, cm0.605
 ≤124
 1–32289
 3–526107
 >51184
Length of needle through normal parenchyma, mm0.011a
 <114124
 1–331102
 ≥31658
Needle-hilus angle, °0.156
 0–302295
 30–6032125
 60–90763
Needle adjustments0.285
 138176
 2–31483
 ≥4925
Operator/s0.210
 134136
 21560
 31288

Statistically significant difference.

Table V

Correlation between factors and hemorrhage.

CharacteristicHemorrhage, nNon-hemorrhage, nP-value
Gender0.747
 Male75154
 Female4076
Age, years0.455
 17–492743
 50–6955125
 70–863362
Smoking status0.697
 Non-smoker2041
 Current or ex-smoker5294
 Unknown4395
Patient position0.211
 Supine3273
 Prone72123
 Decubitus1134
Lesion location
 Lobe0.466
  Upper65122
  Middle723
  Lower4385
 Zone0.336
  Outer1441
  Middle3674
  Inner65115
Effusion0.134
 No1033
 Yes105197
Maximal diameter, cm0.005a
 ≤151
 1–34368
 3–54588
 >52273
Length of needle through normal parenchyma, mm0.000a
 <118120
 1–34984
 ≥34826
Needle-hilus angle, °0.465
 0–303681
 30–6055102
 60–902347
Needle adjustments0.000a
 153161
 2–34859
 ≥41420
Operator/s0.797
 155115
 22451
 33664

Statistically significant difference.

Discussion

In the present study, the incidence of pneumothorax was 17.5%, with 1.5% requiring chest tube drainage. These results are comparable to prior studies (9–11). The decubitus position was found to result in more pneumothoraxes than the supine and prone positions. We hypothesize that the decubitus position separates the parietal and visceral pleura more than the other positions and therefore, air is more likely to enter the pleural cavity as the needle is taken out. Moreover, the majority of lung lesions were found to be located in the middle or inner zone of the lung in the present study. In the biopsy of lesions located in the middle or inner zone of the lung, it is more difficult to keep away from the interlobar pleural; if it is damged, it is more likely to result in pneumothorax. O’Neill et al(12) reported that rapidly (within 10 sec) rolling the patient over to the biopsy-side-down position following needle-out reduced the rate of overall pneumothorax and pneumothorax necessitating a drainage catheter. Moreover, smoking, the decubitus position and a longer length needle in the normal parenchyma were risk factors for a pneumothorax. It is generally considered that a pneumothorax is the most common complication of a needle biopsy of the lung (11,13). However, in the present study, the incidence of hemorrhage (32.9%) was higher than pneumothorax (17.5%) and also higher than the 1–27% reported in the literature (7,11,14). This may be since a pneumothorax is easier to identify in chest radiographs and its obvious symptoms are apt to attract notice. By contrast, mild hemorrhage is difficult to identify in chest radiographs. Furthermore, the current data was based on the presence of haziness on CT images and hemoptysis, instead of hemoptysis only. The results showed that a small diameter and longer length of the needle in the normal parenchyma and more frequent adjustments of the needle were poor predictive factors of hemorrhage. With regard to pathological yield, in the present study, the false positive and false negative rates and the PPV and NPV were 0, 2.7, 100 and 87.7%, respectively. When a malignant diagnosis is identified by needle biopsy, the clinical decision-making process is generally straightforward due to the extremely low false-positive rates (0.0–1%) (3,15). However, when a benign diagnosis is obtained, there is clinical uncertainty over how to proceed, as a number of these lesions may prove to be malignant (false negatives). Previous studies have evaluated the outcomes following a benign biopsy and have found false negative rates that vary widely (2–54%) (16–18). Combining the results of the present and relevant previous studies, we recommend that patients with benign CNB diagnoses undergo repeat imaging for ≥2 years to document the stability or resolution of the lesions. If the nodule grows, a repeat biopsy (19–21) or resection (22) may be required to obtain a definitive diagnosis. The main limitations of the present study were as follows: Firstly, in the analysis of the correlation between factors and complications, single factors were considered individually without excluding the affect of other factors. Secondly, a small number of patients were lost for follow-up and a two-year follow-up may not have been sufficient. In conclusion, CT-guided core needle biopsy of the lung lesions provides a high diagnostic yield. Smoking, the decubitus position and a longer length of needle in the normal parenchyma were risk factors for pneumothorax. In addition, small diameter, a longer length of needle in the normal parenchyma and more frequent adjustments of the needle were poor predictive factors of hemorrhage.
  21 in total

1.  Guidelines for radiologically guided lung biopsy.

Authors:  A Manhire; M Charig; C Clelland; F Gleeson; R Miller; H Moss; K Pointon; C Richardson; E Sawicka
Journal:  Thorax       Date:  2003-11       Impact factor: 9.139

2.  Transthoracic image-guided biopsy of lung nodules: when is benign really benign?

Authors:  Clare Savage; Eric M Walser; Vicki Schnadig; Kenneth J Woodside; Evren Ustuner; Joseph B Zwischenberger
Journal:  J Vasc Interv Radiol       Date:  2004-02       Impact factor: 3.464

3.  CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions: diagnostic yield in 83 lesions.

Authors:  Daisaku Inoue; Hideo Gobara; Takao Hiraki; Hidefumi Mimura; Katsuya Kato; Kentaro Shibamoto; Tatsuhiko Iishi; Yusuke Matsui; Shinichi Toyooka; Susumu Kanazawa
Journal:  Eur J Radiol       Date:  2010-12-28       Impact factor: 3.528

Review 4.  Complications of CT-guided percutaneous needle biopsy of the chest: prevention and management.

Authors:  Carol C Wu; Michael M Maher; Jo-Anne O Shepard
Journal:  AJR Am J Roentgenol       Date:  2011-06       Impact factor: 3.959

5.  Rapid needle-out patient-rollover time after percutaneous CT-guided transthoracic biopsy of lung nodules: effect on pneumothorax rate.

Authors:  Ailbhe C O'Neill; Colin McCarthy; Carole A Ridge; Patrick Mitchell; Emer Hanrahan; Marcus Butler; Michael P Keane; Jonathan D Dodd
Journal:  Radiology       Date:  2011-11-21       Impact factor: 11.105

6.  The role of transbronchial fine needle aspiration in an integrated care pathway for the assessment of patients with suspected lung cancer.

Authors:  Pallav L Shah; Suveer Singh; Mark Bower; Naomi Livni; Simon Padley; Andrew G Nicholson
Journal:  J Thorac Oncol       Date:  2006-05       Impact factor: 15.609

7.  CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan.

Authors:  Noriyuki Tomiyama; Yoshifumi Yasuhara; Yasuo Nakajima; Shuji Adachi; Yasuaki Arai; Masahiko Kusumoto; Kenji Eguchi; Keiko Kuriyama; Fumikazu Sakai; Masayuki Noguchi; Kiyoshi Murata; Sadayuki Murayama; Teruhito Mochizuki; Kiyoshi Mori; Kozo Yamada
Journal:  Eur J Radiol       Date:  2006-03-10       Impact factor: 3.528

8.  CT-guided cutting needle lung biopsy using modified coaxial technique: factors effecting risk of complications.

Authors:  Erkan Yildirim; Ismail Kirbas; Ali Harman; Umut Ozyer; H Gurkan Tore; Cuneyt Aytekin; Fatih Boyvat
Journal:  Eur J Radiol       Date:  2008-02-21       Impact factor: 3.528

9.  Transthoracic needle aspiration biopsy of benign and malignant lung lesions.

Authors:  N F Khouri; F P Stitik; Y S Erozan; P K Gupta; W S Kim; W W Scott; U M Hamper; R B Mann; J C Eggleston; R R Baker
Journal:  AJR Am J Roentgenol       Date:  1985-02       Impact factor: 3.959

10.  Percutaneous needle aspiration biopsy (PCNAB) of lung lesions: 5 years results with focusing on repeat PCNAB.

Authors:  In Jae Lee; Young-A Bae; Dong Gyu Kim; Ki-Suck Jung; Hyoung June Im; Kwanseop Lee; Yul Lee; Sang Hoon Bae
Journal:  Eur J Radiol       Date:  2009-02-05       Impact factor: 3.528

View more
  14 in total

1.  Efficacy of an opposite position aspiration on resolution of pneumothorax following CT-guided lung biopsy.

Authors:  L-C Zeng; Y Du; H-F Yang; M-G Xie; H-Q Liao; Y-D Zhang; L Li; Q Wang; L Hu; X-X Xu
Journal:  Br J Radiol       Date:  2015-05-12       Impact factor: 3.039

2.  [Invasive procedure for clarification of pulmonary nodules].

Authors:  A H Mahnken
Journal:  Radiologe       Date:  2014-05       Impact factor: 0.635

3.  Intraoperative core needle biopsy under complete video-assisted thoracic surgery for indeterminate tumor of lung.

Authors:  Tetsuya Isaka; Ko Takahashi; Takamitsu Maehara; Munetaka Masuda
Journal:  Surg Endosc       Date:  2015-03-05       Impact factor: 4.584

4.  Comparison between endobronchial ultrasound-guided transbronchial biopsy and CT-guided transthoracic lung biopsy for the diagnosis of peripheral lung cancer: a systematic review and meta-analysis.

Authors:  Ping Zhan; Qing-Qing Zhu; Ying-Ying Miu; Ya-Fang Liu; Xiao-Xia Wang; Ze-Jun Zhou; Jia-Jia Jin; Qian Li; Shinji Sasada; Takehiro Izumo; Chih-Yen Tu; Wen-Chien Cheng; Matthew Evison; Tang-Feng Lv; Yong Song
Journal:  Transl Lung Cancer Res       Date:  2017-02

5.  Prospective Randomized Trial for Image-Guided Biopsy Using Cone-Beam CT Navigation Compared with Conventional CT.

Authors:  Nadine Abi-Jaoudeh; Teresa Fisher; John Jacobus; Marlene Skopec; Alessandro Radaelli; Imramsjah Martijn Van Der Bom; Robert Wesley; Bradford J Wood
Journal:  J Vasc Interv Radiol       Date:  2016-07-25       Impact factor: 3.464

6.  Clinical research on the combined use of systemic chemotherapy and CT-guided radiofrequency ablation in treatment of lung cancer.

Authors:  Feng Xu; Zhigang Cai; Beizheng Xu; Jian Song; Haiyan Liu; Xuanmei Li; Aibing Deng; Xiaotang Wu; Jun Chen
Journal:  Lasers Med Sci       Date:  2021-01-08       Impact factor: 3.161

7.  Non-diagnostic Results of Percutaneous Transthoracic Needle Biopsy: A Meta-analysis.

Authors:  Kum Ju Chae; Hyunsook Hong; Soon Ho Yoon; Seokyung Hahn; Gong Yong Jin; Chang Min Park; Jin Mo Goo
Journal:  Sci Rep       Date:  2019-08-27       Impact factor: 4.379

8.  Pneumothorax rates in CT-Guided lung biopsies: a comprehensive systematic review and meta-analysis of risk factors.

Authors:  Ya Ruth Huo; Michael Vinchill Chan; Al-Rahim Habib; Isaac Lui; Lloyd Ridley
Journal:  Br J Radiol       Date:  2020-01-03       Impact factor: 3.039

9.  Comparative study of cytology and immunocytochemistry with trucut biopsy and immunohistochemistry in diagnosis of localized lung lesions: A prospective study.

Authors:  Shravasti Roy; Ayandip Nandi; Indranil Das; Palash K Mandal
Journal:  J Cytol       Date:  2015 Apr-Jun       Impact factor: 1.000

10.  Chinese multidisciplinary expert consensus: Guidelines on percutaneous transthoracic needle biopsy.

Authors:  Zhi Guo; Hong Shi; Wentao Li; Dongmei Lin; Changli Wang; Chen Liu; Min Yuan; Xia Wu; Bin Xiong; Xinhong He; Feng Duan; Jianjun Han; Xueling Yang; Haipeng Yu; Tongguo Si; Linfeng Xu; Wenge Xing; Huang Jinhua; Yingjuan Wang; Hui Xie; Li Cui; Wei Gao; Dongfeng He; Changfu Liu; Zhou Liu; Chunhua Ma; Jie Pan; Haibo Shao; Qiang Tu; Li Yong; Yan Xu; Zhang Weihao; Zou Qiang; Sen Wang
Journal:  Thorac Cancer       Date:  2018-09-17       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.