Literature DB >> 24346079

Microdesiccates produced from normal human tears display four distinctive morphological components.

Remigio López Solís1, Leonidas Traipe Castro2, Daniela Salinas Toro1, Miguel Srur2, Héctor Toledo Araya1.   

Abstract

Desiccation of human tears on glass surfaces results in fern-like crystalloids. This phenomenon has been associated with tear normality (Tear Ferning Test, TFT) and is used as a diagnostic aid to evaluate patients with Dry-Eye disease. However, TFT is focused on the assessment of only a minor fraction of desiccated tear samples and considers only the relative abundance and density of fern-like crystalloids. The aim of this study was to characterize morphologically entire desiccated micro volumes of tears from healthy donors. Tear samples were collected from 23 healthy young adult volunteers. Tear aliquots (1-3 μL) were allowed to dry on glass surfaces under ambient conditions of temperature (15-25°C) and relative humidity (40-45%). Dry samples were analyzed by dark-field microscopy. Morphometric data were acquired with Image J software. Tear volume was positively correlated with both area and time of desiccation. Morphological features of multiple microdesiccates produced from a single subject displayed striking similarities whereas tear microdesiccates from different healthy subjects displayed consistent differences but shared a common general design. This design may be mostly represented by the occurrence of four distinctive zones, named as zones I, II, III and Transition band. The main features of these zones are described.

Entities:  

Mesh:

Year:  2013        PMID: 24346079     DOI: 10.4067/S0716-97602013000300012

Source DB:  PubMed          Journal:  Biol Res        ISSN: 0716-9760            Impact factor:   5.612


  3 in total

1.  Dynamics of tear fluid desiccation on a glass surface: a contribution to tear quality assessment.

Authors:  Leonidas Traipe-Castro; Daniela Salinas-Toro; Daniela López; Mario Zanolli; Miguel Srur; Felipe Valenzuela; Aníbal Cáceres; Héctor Toledo-Araya; Remigio López-Solís
Journal:  Biol Res       Date:  2014-06-04       Impact factor: 5.612

2.  Establishment of a Tear Ferning Test Protocol in the Mouse Model.

Authors:  Yu-Jun Tang; Han-Hsin Chang; Chih-Ying Tsai; Ling-Yun Chen; David Pei-Cheng Lin
Journal:  Transl Vis Sci Technol       Date:  2020-12-01       Impact factor: 3.283

3.  Progress in tear microdesiccate analysis by combining various transmitted-light microscope techniques.

Authors:  Felipe Traipe-Salas; Leonidas Traipe-Castro; Daniela Salinas-Toro; Daniela López; Felipe Valenzuela; Christian Cartes; Héctor Toledo-Araya; Claudio Pérez; Remigio López Solís
Journal:  Biol Res       Date:  2016-06-03       Impact factor: 5.612