Literature DB >> 24345768

Impact of beta-blockade premedication on image quality of ECG-gated thoracic aorta CT angiography.

Pegah Entezari1, Jeremy Collins1, Hamid Chalian1, Huseyin Gurkan Tore1, James Carr1, Vahid Yaghmai2.   

Abstract

BACKGROUND: Thoracic aortic aneurysm is one of the most common aorta pathologies worldwide, which is commonly evaluated by computed tomography angiography (CTA). One of the routine methods to improve the image quality of CTA is heart rate reduction prior to study by beta-blockade administration.
PURPOSE: To assess the effect of beta-blockade on image quality of the ascending aorta in electrocardiography (ECG)-gated dual-source CTA (DSCTA) images.
MATERIAL AND METHODS: In this retrospective study, ECG-gated thoracic aorta CTA images of 40 patients without beta-blocker administration were compared with ECG-gated images of 40 patients with beta-blockade. Images of the aorta were analyzed objectively and subjectively at three levels: sinus of Valsalva (sinus), sinotubular junction (STJ), and mid ascending aorta (MAA). Quantitative sharpness index (SI) and signal-to-noise ratio (SNR) were calculated and two radiologists evaluated the image quality using a 3-point scale.
RESULTS: Mean heart rate in beta-blocker and non-beta-blocker groups was 61.7 beats per minute (bpm) (range, 58.1-63.9 bpm) and 72.9 bpm (range, 69.3-84.1 bpm), respectively (P < 0.05). Aorta wall SI, SNR, and subjective grading were comparable between the two groups at all three levels (P > 0.05).
CONCLUSION: Beta-blocker premedication may not be necessary for imaging of ascending aorta with ECG-gated DSCTA. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Entities:  

Keywords:  Computed tomography angiography; ascending aorta; beta-antagonist; heart rate; image quality

Mesh:

Substances:

Year:  2013        PMID: 24345768     DOI: 10.1177/0284185113516950

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  2 in total

1.  Is ECG triggering for motion artefact reduction in dual-source CT angiography of the ascending aorta still required with high-pitch scanning? The role of ECG-gating in high-pitch dual-source CT of the ascending aorta.

Authors:  Alice Wielandner; Dietrich Beitzke; Ruediger Schernthaner; Florian Wolf; Christina Langenberger; Alfred Stadler; Christian Loewe
Journal:  Br J Radiol       Date:  2016-06-01       Impact factor: 3.039

Review 2.  Vascular CT and MRI: a practical guide to imaging protocols.

Authors:  D J Murphy; A Aghayev; M L Steigner
Journal:  Insights Imaging       Date:  2018-03-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.