Literature DB >> 24338539

Efficacy of multi-electrode duty-cycled radiofrequency ablation in patients with paroxysmal and persistent atrial fibrillation.

Edward Koźluk, Paweł Balsam1, Michał Peller, Marek Kiliszek, Piotr Lodziński, Agnieszka Piątkowska, Sylwia Małkowska, Dariusz Rodkiewicz, Janusz Kochanowski, Grzegorz Opolski.   

Abstract

BACKGROUND: Radiofrequency (RF) catheter ablation is a first-line therapy for patients withdrug-refractory atrial fibrillation (AF). Complete isolation of electrical potentials at the ostium of pulmonary vein (PV) is a challenging procedure. There are different techniques and devicesused for PV isolation (PVI). The objective of this study was to evaluate the efficacy and safety of PV ablation catheter (PVAC).
METHODS: A total of 67 consecutive patients with paroxysmal and persistent AF were treated with the PVAC. The patients' information were obtained from clinical charts. Follow-up was obtained by one day Holter monitoring at 2, 4, 6, 8, 10 and 12 months after ablation and ECG registration if any symptoms or arrhythmia occurred.
RESULTS: The median follow-up duration was 16 months (IQR: 12-20 months). In the population which was available at follow-up (n = 60), 22 (36.7%) patients were in sustained sinus rhythm (SR) without anti-arrhythmic drugs (AAD). Overall 26 (43.3%) patients were in sustained SR with and without AAD. In the paroxysmal AF group, after a single PVAC ablation procedure (n = 39), 19 (48.7%) patients had sustained SR without AAD. In the persistent AF group (n = 15), after the single PVAC ablation, 2 (13.3%) patients had sustained SR without AAD.
CONCLUSIONS: PVI with PVAC is a safe procedure with 48.7% efficacy in patients with paroxysmal AF. The efficacy of PVAC in patients with persistent or long-standing persistent AF is not acceptable.

Entities:  

Mesh:

Year:  2013        PMID: 24338539     DOI: 10.5603/CJ.2013.0162

Source DB:  PubMed          Journal:  Cardiol J        ISSN: 1898-018X            Impact factor:   2.737


  2 in total

1.  Direct results of a prospective randomized study comparing ablation with the nMARQ catheter and the PVAC catheter used with and without a 3D system (MAPER 3D Study).

Authors:  Edward Koźluk; Agnieszka Piątkowska; Dariusz Rodkiewicz; Michał Peller; Janusz Kochanowski; Grzegorz Opolski
Journal:  Arch Med Sci       Date:  2017-05-30       Impact factor: 3.318

2.  Is the Time of Atrial Fibrillation Recurrence After Duty-Cycled Radiofrequency Ablation Affected by the Pattern of Pulmonary Vein Reconnections?

Authors:  Marcus Wieczorek; Kiarash Sassani; Reinhard Hoeltgen
Journal:  Cardiol Res       Date:  2020-05-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.