Literature DB >> 24337922

Medical iPad use in the cardiac catheterization and echo laboratories.

Ifat Lavi1, Guy Malki, Ran Kornowski.   

Abstract

The present study aims to describe a dedicated cardiac imaging application on a tablet and to assess the accuracy and reproducibility of this novel application for measurement on angiography and echocardiography data sets. Tablet devices have recently been used in radiological image interpretation and enable transfer of images. It allows the clinician to look up clinical information, search the Internet and communicate with colleagues and family. The study group consisted of 30 patients who had both echocardiographic and angiographic examinations. For each patient, a few measurements (i.e. length, area and angle) were performed using the iPad, and compared to the McKesson workstation, which is routinely used in the hospital. In order to show the equivalence between these two methods, a linear regression was fitted and the distribution of differences between measurements was examined. In addition, the variability of the measurements was compared between two different reviewers (inter-observer test) and between the measurements of the same reviewer at two different time settings (intra-observer test) by calculating the intraclass correlation coefficient (ICC). In all comparisons, the linear regression showed high correlation coefficient (r > 0.9), and the distribution of differences was around zero, implying that the two methods lead to equivalent results. The absolute mean difference between the two different observers demonstrated high agreement between the two observers' repeated measurements. The same conclusions can be deduced from the same observer's repeated measurements. The ICC indicates the resemblance between the two sets, and could be considered almost perfect (ICC > 0.968 for all cases). The newly developed cardiology iPad application offers the opportunity to accurately present the cardiac procedure in a visual, clear and professional manner.

Entities:  

Mesh:

Year:  2013        PMID: 24337922     DOI: 10.1007/s10554-013-0352-1

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  5 in total

1.  Emergency CT brain: preliminary interpretation with a tablet device: image quality and diagnostic performance of the Apple iPad.

Authors:  Patrick Mc Laughlin; Siobhan O Neill; Noel Fanning; Anne Marie Mc Garrigle; Owen J O Connor; Gerry Wyse; Michael M Maher
Journal:  Emerg Radiol       Date:  2011-12-16

2.  The iPad in cardiology: tool or toy?

Authors:  Walter Mashman
Journal:  JACC Cardiovasc Interv       Date:  2011-02       Impact factor: 11.195

3.  A lung segmentectomy performed with 3D reconstruction images available on the operating table with an iPad.

Authors:  Francesco Volonté; John Henri Robert; Osman Ratib; Frédéric Triponez
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-03-08

4.  Scalpel, stethoscope, iPad: the future is now in the intensive care unit.

Authors:  Richard H Savel; Cindy L Munro
Journal:  Am J Crit Care       Date:  2011-07       Impact factor: 2.228

5.  Three-dimensional imaging navigation during a lung segmentectomy using an iPad.

Authors:  Takashi Eguchi; Keiichiro Takasuna; Atsushi Kitazawa; Youhei Fukuzawa; Yasuo Sakaue; Kazuo Yoshida; Makoto Matsubara
Journal:  Eur J Cardiothorac Surg       Date:  2012-01-18       Impact factor: 4.191

  5 in total
  1 in total

Review 1.  Cardiovascular imaging 2014 in the International Journal of Cardiovascular Imaging.

Authors: 
Journal:  Int J Cardiovasc Imaging       Date:  2015-03       Impact factor: 2.357

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.