Literature DB >> 24337228

Numerical simulation of vertebral artery stenosis treated with different stents.

Aike Qiao, Zhanzhu Zhang.   

Abstract

We sought to investigate the effects of endovascular stents with different links for treating stenotic vertebral artery and to determine the relationship between the shape of the link and in-stent restenosis (ISR). We also attempted to provide scientific guidelines for stent design and selection for clinical procedures. Models of three types of stent with different links (L-stent, V-stent, and S-stent) and an idealized stenotic vertebral artery were established. The deployment procedure for the stent in the stenotic vertebral artery was simulated for solid mechanics analysis. Next, the deformed models were extracted to construct the blood flow domain, and numerical simulations of the hemodynamics in these models were performed using the finite element method. The numerical results demonstrated that: (1) Compared with the L-stent and V-stent, the S-stent has a better flexibility and induces less stress in the stent strut. Furthermore, less stress is generated in the arterial wall. (2) Vascular straightening is scarcely influenced by the shape of the link, but it is closely related to the flexibility of the stent. (3) The S-stent has the smallest foreshortening among the three types of stents. (4) Compared with the V-stent and S-stent, the L-stent causes a smaller area with low wall shear stress, less blood stagnation area, and better blood flow close to the artery wall. From the viewpoint of the combination of solid mechanics and hemodynamics, the S-stent has better therapeutic effects because of its lower potential for inducing ISR and its better prospects in clinical applications compared with the L-stent and V-stent.

Entities:  

Mesh:

Year:  2014        PMID: 24337228     DOI: 10.1115/1.4026229

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  3 in total

1.  Long-term hemodynamic mechanism of enhanced external counterpulsation in the treatment of coronary heart disease: a geometric multiscale simulation.

Authors:  Bao Li; Wenxin Wang; Boyan Mao; Haisheng Yang; Haijun Niu; Jianhang Du; Xiaoling Li; Youjun Liu
Journal:  Med Biol Eng Comput       Date:  2019-09-14       Impact factor: 2.602

2.  Design and Optimization of a New Anti-reflux Biliary Stent With Retractable Bionic Valve Based on Fluid-Structure Interaction Analysis.

Authors:  Yushan Su; Zhongxia Xiang; Xiaofei Song; Shuxian Zheng; Xinsheng Xu
Journal:  Front Bioeng Biotechnol       Date:  2022-03-28

3.  Determination of the Influence of Strut Connector on Stent Deployment.

Authors:  V Hashim; S L Resmi; P N Dileep
Journal:  Appl Bionics Biomech       Date:  2022-06-28       Impact factor: 1.664

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.