Literature DB >> 24335806

Flow diverter assisted coil embolization of a very small ruptured ophthalmic artery aneurysm.

David Dornbos1, Promod Pillai1, Eric Sauvageau1.   

Abstract

Small ruptured aneurysms present a unique problem to endovascular therapy. We report a case in which a patient presented with subarachnoid hemorrhage and a very small ruptured ophthalmic artery aneurysm, for which endovascular therapy was preferred secondary to severe cardiac comorbidities. Due to the aneurysm size, a small 1.5 mm coil was needed, but presented a significant risk of migration. Conventional stent assisted coiling was considered suboptimal as the small coil could have easily migrated through the strut. We present a novel technique of flow diverter assisted coil embolization in which a coil was placed within the aneurysm and a pipeline embolization device was then partially deployed, jailing the microcatheter and coil mass. Once in place, the coil was detached, securing the aneurysm, and preventing coil migration. Through the use of a flow diverter, some degree of aneurysm protection would still be expected in the event of coil migration toward the ophthalmic artery origin. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

Entities:  

Keywords:  Aneurysm; Angiography; Coil; Flow Diverter; Subarachnoid

Mesh:

Year:  2013        PMID: 24335806     DOI: 10.1136/neurintsurg-2013-010876.rep

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  4 in total

1.  Pipeline Embolization Device with or without Adjunctive Coil Embolization: Analysis of Complications from the IntrePED Registry.

Authors:  M S Park; C Kilburg; P Taussky; F C Albuquerque; D F Kallmes; E I Levy; P Jabbour; I Szikora; E Boccardi; R A Hanel; A Bonafé; C G McDougall
Journal:  AJNR Am J Neuroradiol       Date:  2016-01-14       Impact factor: 3.825

Review 2.  Endovascular treatment of aneurysms of the paraophthalmic segment of the internal carotid artery: Current status.

Authors:  Yiheng Wang; Jinlu Yu
Journal:  Front Neurol       Date:  2022-09-16       Impact factor: 4.086

3.  Anchoring Pipeline Flow Diverter Construct in the Treatment of Traumatic Distal Cervical Carotid Artery Injury.

Authors:  Krishna Amuluru; Fawaz Al-Mufti; William Roth; Charles J Prestigiacomo; Chirag D Gandhi
Journal:  Interv Neurol       Date:  2017-04-19

4.  Electrothermal Coil Detachment Failure in Flow Diverter-Assisted Coiling of a Small Blister Aneurysm: Technical Considerations and Possible Solutions.

Authors:  Gwynedd E Pickett; Adela Cora
Journal:  Neurointervention       Date:  2021-04-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.