Literature DB >> 24334821

Three-dimensional personalized dosimetry for 188Re liver selective internal radiation therapy based on quantitative post-treatment SPECT studies.

S Shcherbinin1, J Grimes, A Bator, J B Cwikla, A Celler.   

Abstract

We demonstrate that accurate patient-specific distributions of microspheres labeled with 188Re and resulting absorbed doses can be obtained from single-photon emission computed tomography (SPECT) studies performed after 188Re selective internal radiation therapy when accurate correction methods are employed in image reconstruction. Our quantitative image reconstruction algorithm includes corrections for attenuation, resolution degradations and scatter as well as a window-based compensation for contamination. The procedure has been validated using four phantom experiments containing an 18 ml cylindrical source (82-93 MBq of 188Re activity) simulating a liver tumor. In addition, we applied our approach to post-therapy SPECT studies of ten patients with progressive primary or metastatic liver carcinomas. Our quantitative algorithm accurately (within 9%) recovered 188Re activity from four phantom experiments. In addition, for two patients that received three scans, deviations remained consistent between the measured and the reconstructed activities that were determined from studies with differing severity of the dead-time effect. The analysis of absorbed doses for patient studies allowed us to hypothesize that D90 (the minimum dose received by 90% of the tumor volume) may be a reliable metric relating therapy outcomes to the calculated doses. Among several considered metrics, only D90 showed statistically significant correlation with the overall survival.

Entities:  

Year:  2013        PMID: 24334821     DOI: 10.1088/0031-9155/59/1/119

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Accuracy of 177Lu activity quantification in SPECT imaging: a phantom study.

Authors:  Carlos F Uribe; Pedro L Esquinas; Jesse Tanguay; Marjorie Gonzalez; Emilie Gaudin; Jean-Mathieu Beauregard; Anna Celler
Journal:  EJNMMI Phys       Date:  2017-01-07

2.  Biodistribution, pharmacokinetics, and organ-level dosimetry for 188Re-AHDD-Lipiodol radioembolization based on quantitative post-treatment SPECT/CT scans.

Authors:  Pedro L Esquinas; Ajit Shinto; Koramadai K Kamaleshwaran; Jephy Joseph; Anna Celler
Journal:  EJNMMI Phys       Date:  2018-12-07

3.  Radioembolization of Hepatocellular Carcinoma with Built-In Dosimetry: First in vivo Results with Uniformly-Sized, Biodegradable Microspheres Labeled with 188Re.

Authors:  José Carlos De La Vega; Pedro Luis Esquinas; Cristina Rodríguez-Rodríguez; Mehrdad Bokharaei; Igor Moskalev; David Liu; Katayoun Saatchi; Urs O Häfeli
Journal:  Theranostics       Date:  2019-01-25       Impact factor: 11.556

4.  Initial study of radiological and clinical efficacy radioembolization using 188Re-human serum albumin (HSA) microspheres in patients with progressive, unresectable primary or secondary liver cancers.

Authors:  Mirosław L Nowicki; Jarosław B Cwikla; Artur J Sankowski; Sergey Shcherbinin; Josh Grimmes; Anna Celler; John R Buscombe; Andrzej Bator; Maciej Pech; Renata Mikołajczak; Dariusz Pawlak
Journal:  Med Sci Monit       Date:  2014-08-02

5.  Determination of gamma camera calibration factors for quantitation of therapeutic radioisotopes.

Authors:  Wei Zhao; Pedro L Esquinas; Xinchi Hou; Carlos F Uribe; Marjorie Gonzalez; Jean-Mathieu Beauregard; Yuni K Dewaraja; Anna Celler
Journal:  EJNMMI Phys       Date:  2018-05-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.