Literature DB >> 24334816

Clinical utility of computed tomographic lung volumes in patients with chronic obstructive pulmonary disease.

Jae Seung Lee1, Sang-Min Lee, Joon Beom Seo, Sei Won Lee, Jin Won Huh, Yeon-Mok Oh, Sang-Do Lee.   

Abstract

BACKGROUND: Published data concerning the utility of computed tomography (CT)-based lung volumes are limited to correlation with lung function.
OBJECTIVES: The aim of this study was to evaluate the clinical utility of the CT expiratory-to-inspiratory lung volume ratio (CT Vratio) by assessing the relationship with clinically relevant outcomes.
METHODS: A total of 75 stable chronic obstructive pulmonary disease (COPD) patients having pulmonary function testing and volumetric CT at full inspiration and expiration were retrospectively evaluated. Inspiratory and expiratory CT lung volumes were measured using in-house software. Correlation of the CT Vratio with patient-centered outcomes, including the modified Medical Research Council (MMRC) dyspnea score, the 6-min walk distance (6MWD), the St. George's Respiratory Questionnaire (SGRQ) score, and multidimensional COPD severity indices, such as the BMI, airflow obstruction, dyspnea, and exercise capacity index (BODE) and age, dyspnea, and airflow obstruction (ADO), were analyzed.
RESULTS: The CT Vratio correlated significantly with BMI (r = -0.528, p < 0.001). The CT Vratio was also significantly associated with MMRC dyspnea (r = 0.387, p = 0.001), 6MWD (r = -0.459, p < 0.001), and SGRQ (r = 0.369, p = 0.001) scores. Finally, the CT Vratio had significant correlations with the BODE and ADO multidimensional COPD severity indices (r = 0.605, p < 0.001; r = 0.411, p < 0.001).
CONCLUSION: The CT Vratio had significant correlations with patient-centered outcomes and multidimensional COPD severity indices.
© 2013 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2013        PMID: 24334816     DOI: 10.1159/000355097

Source DB:  PubMed          Journal:  Respiration        ISSN: 0025-7931            Impact factor:   3.580


  2 in total

1.  Implications of the pulmonary artery to ascending aortic ratio in patients with relatively mild chronic obstructive pulmonary disease.

Authors:  Cho Rom Hahm; Myoung Nam Lim; Hee Yeong Kim; Seok-Ho Hong; Seon-Sook Han; Seung-Joon Lee; Woo Jin Kim; Yoonki Hong
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

2.  Uncertainty analysis of chest X-ray lung height measurements and size matching for lung transplantation.

Authors:  Rodrigo Vazquez Guillamet; Maria C Vazquez Guillamet; Ashraf Rjob; Andrew Bierhals; Irene Bello; Alberto Jauregui Abularach; Laneshia Tague; Michael Wallendorf; Gary F Marklin; Chad Witt; Derek E Byers; Daniel Kreisel; Ruben Nava; Varun Puri; Ramsey Hachem; Elbert P Trulock
Journal:  J Thorac Dis       Date:  2022-04       Impact factor: 3.005

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.