Literature DB >> 24333686

Development of a multiplex real-time PCR assay for the detection of Bordetella pertussis and Bordetella parapertussis in a single tube reaction.

Sophie Arbefeville1, Michael H Levi2, Patricia Ferrieri3.   

Abstract

Pertussis is an infectious respiratory disease caused by the fastidious bacterium Bordetella pertussis, which may infect unvaccinated, previously vaccinated children, and adults in whom immunity has waned. Infants are at a particular risk for severe disease and complications. Bordetella parapertussis may cause a similar illness, however the symptoms are less severe and of shorter duration. Pertussis is a highly contagious disease and early diagnosis is essential. Studies have shown that PCR is 2-4 times more likely than culture to detect Bordetella pertussis. We developed a multiplex, real-time PCR assay using analyte-specific reagent (ASR) primers and probes dispensed in a convenient lyophilized bead format that targeted the multi-copy insertion sequences IS481 and IS1001 of B. pertussis and B. parapertussis, respectively. These specific ASRs were used in conjunction with Cepheid Smartmix. Included in the ASRs is a competitive internal control to evaluate the performance of the PCR reaction. After DNA extraction, amplification and detection were done on the Smart Cycler System, which performs integrated amplification and detection automatically in a single step. Specificity of the assay was confirmed using multiple distinct bacterial strains. Sensitivity of the assay and extraction efficiency were evaluated on DNA isolated from pure bacterial cultures and on spiked respiratory specimens. We also spiked different swab types and transport media to evaluate for interfering substances. To assess accuracy, we studied different patient specimen types received from two outside laboratories that used similar or different methods to detect B. pertussis and B. parapertussis. The sensitivity and the specificity of the assay for B. pertussis were 90% and 96%, respectively, and for B. parapertussis 71% (only 7 positive specimens were available for testing) and 100%, respectively. Our assay was found to be a valid method for the simultaneous detection of B. pertussis and B. parapertussis.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bordetella parapertussis; Bordetella pertussis; Multiplex real-time polymerase chain reaction (PCR)

Mesh:

Substances:

Year:  2013        PMID: 24333686     DOI: 10.1016/j.mimet.2013.12.003

Source DB:  PubMed          Journal:  J Microbiol Methods        ISSN: 0167-7012            Impact factor:   2.363


  3 in total

1.  Evaluation of Level of Agreement in Bordetella Species Identification in Three U.S. Laboratories during a Period of Increased Pertussis.

Authors:  Brunilís Burgos-Rivera; Adria D Lee; Katherine E Bowden; Amanda E Faulkner; Brent L Seaton; Bryndon D Lembke; Charles P Cartwright; Stacey W Martin; M Lucia Tondella
Journal:  J Clin Microbiol       Date:  2015-03-25       Impact factor: 5.948

2.  Comparison of rates of positivity for Bordetella pertussis by real-time PCR between specimens collected with rayon swabs on aluminum wire shaft in Amies gel with charcoal and specimens collected with flocked swabs in universal viral transport medium during an epidemic.

Authors:  Sophie Arbefeville; Patricia Ferrieri
Journal:  J Clin Microbiol       Date:  2014-04-30       Impact factor: 5.948

3.  Validation and Implementation of a Diagnostic Algorithm for DNA Detection of Bordetella pertussis, B. parapertussis, and B. holmesii in a Pediatric Referral Hospital in Barcelona, Spain.

Authors:  Ana Valero-Rello; Desiree Henares; Lesly Acosta; Mireia Jane; Iolanda Jordan; Pere Godoy; Carmen Muñoz-Almagro
Journal:  J Clin Microbiol       Date:  2019-01-02       Impact factor: 5.948

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.